pktcSigPulseSignalPulseInterval

PKTC-IETF-SIG-MIB · .1.3.6.1.2.1.169.1.1.20.1.5

Object

column r/w Milliseconds Unsigned32
This object specifies the repeat interval, or the period,
for each signal type.  In addition, the MTA must accept
the values in the incremental steps specific for each
signal type.  The following table defines the default
values and the incremental steps for this object, depending
on the signal type:
              
pktcSigPulseSignaltype  Default (ms)   Increment (ms)
initialRing                 200             50
pulseLoopClose             1000             10
pulseLoopOpen              1000             10
enableMeterPulse           1000             10
meterPulseBurst            1000             10
pulseNoBattery             1000             10
pulseNormalPolarity        1000             10
pulseReducedBattery        1000             10
pulseReversePolarity       1000             10
              
An attempt to set this object to a value that does not
fall on one of the increment boundaries, or on the wrong
increment boundary for the specific signal type, will
result in an 'inconsistentValue' error.

Context

MIB
PKTC-IETF-SIG-MIB
OID
.1.3.6.1.2.1.169.1.1.20.1.5
Type
column
Access
readwrite
Status
current
Units
Milliseconds
Parent
pktcSigPulseSignalEntry
Table
pktcSigPulseSignalTable
Siblings
5

Syntax

Milliseconds Unsigned32

Values & Constraints

No enumerated values or constraints recorded.

Related Objects

Sibling Objects