pktcSigPulseSignalPulseInterval
PKTC-IETF-SIG-MIB ·
.1.3.6.1.2.1.169.1.1.20.1.5
Object
column r/w
MillisecondsUnsigned32
This object specifies the repeat interval, or the period,
for each signal type. In addition, the MTA must accept
the values in the incremental steps specific for each
signal type. The following table defines the default
values and the incremental steps for this object, depending
on the signal type:
pktcSigPulseSignaltype Default (ms) Increment (ms)
initialRing 200 50
pulseLoopClose 1000 10
pulseLoopOpen 1000 10
enableMeterPulse 1000 10
meterPulseBurst 1000 10
pulseNoBattery 1000 10
pulseNormalPolarity 1000 10
pulseReducedBattery 1000 10
pulseReversePolarity 1000 10
An attempt to set this object to a value that does not
fall on one of the increment boundaries, or on the wrong
increment boundary for the specific signal type, will
result in an 'inconsistentValue' error.
Context
- MIB
- PKTC-IETF-SIG-MIB
- OID
.1.3.6.1.2.1.169.1.1.20.1.5- Type
- column
- Access
- readwrite
- Status
- current
- Units
- Milliseconds
- Parent
- pktcSigPulseSignalEntry
- Groups
- 2
Net-SNMP examples
How SNMP and these commands workWalk the column to discover its indexed instances, or supply every index to read one instance.
Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PKTC-IETF-SIG-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PKTC-IETF-SIG-MIB::pktcSigPulseSignalPulseInterval'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'PKTC-IETF-SIG-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PKTC-IETF-SIG-MIB::pktcSigPulseSignalPulseInterval.<index>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'PKTC-IETF-SIG-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'PKTC-IETF-SIG-MIB::pktcSigPulseSignalPulseInterval'
Syntax
MillisecondsUnsigned32
Values & Constraints
No enumerated values or constraints recorded.
Conformance
Member of
Compliance refinements
Object not applicable for the EUE. Object is applicable if
optional feature of Pulse Dialing is supported
optional feature of Pulse Dialing is supported