pktcSigEndPntConfigRingingTO
PKTC-IETF-SIG-MIB ·
.1.3.6.1.2.1.169.1.2.1.1.9
Object
This object contains the default time out value for ringing. The MTA MUST NOT update this object with the value provided in the NCS message (if present). If the value of the object is modified by the SNMP Management Station, the MTA MUST use the new value as a default only for a new signal requested by the NCS message. The time out (TO) elements are intended to limit the time a tone or frequency is generated. When this MIB object is set to a value of '0', the MTA MUST NOT generate the corresponding frequency or tone, regardless of the definitions pertaining to frequency, tone duration, or cadence.
Context
- MIB
- PKTC-IETF-SIG-MIB
- OID
.1.3.6.1.2.1.169.1.2.1.1.9- Type
- column
- Access
- readwrite
- Status
- current
- Units
- seconds
- Parent
- pktcSigEndPntConfigEntry
- Groups
- 1
Net-SNMP examples
How SNMP and these commands workWalk the column to discover its indexed instances, or supply every index to read one instance.
Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PKTC-IETF-SIG-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PKTC-IETF-SIG-MIB::pktcSigEndPntConfigRingingTO'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'PKTC-IETF-SIG-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PKTC-IETF-SIG-MIB::pktcSigEndPntConfigRingingTO.<index>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'PKTC-IETF-SIG-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'PKTC-IETF-SIG-MIB::pktcSigEndPntConfigRingingTO'
Syntax
secondsSNMPv2-SMIUnsigned32
- Source
- SNMPv2-SMIUnsigned32
- Base type
Unsigned32
Values & Constraints
Type Constraints
range: 0..4294967295
Conformance
Member of