pktcSigDevCidAfterDTAS

PKTC-IETF-SIG-MIB · .1.3.6.1.2.1.169.1.1.23

Object

scalar r/w Milliseconds Unsigned32
This object specifies the delay between the end of the
Dual Tone Alert Signal (DT-AS) and the start of the
transmission of the FSK or DTMF containing the caller id
information.  This object is only used when
pktcSigDevCidMode is set to a value of 'dtAsETS' or
'lrAsETS'.
          
The following table defines the default values
for this MIB object, depending on the signal type
(pktcSigDevCidMode), and MUST be followed:
          
Value of pktcSigDevCidMode       Default value
          
          
duringringingETS                 any value (not used)
dtAsETS                          50 ms
rpAsETS                          any value (not used)
lrAsETS                          50 ms
lrETS                            any value (not used)
          
An attempt to set this object while the value of
pktcSigDevCidMode is not 'dtAsETS' or 'lrAsETS' will
result in an 'inconsistentValue' error.
          
The value of this MIB object MUST NOT persist across MTA
reboots.

Context

MIB
PKTC-IETF-SIG-MIB
OID
.1.3.6.1.2.1.169.1.1.23
Type
scalar
Access
readwrite
Status
current
Units
Milliseconds
Parent
pktcSigDevObjects
Siblings
40

Syntax

Milliseconds Unsigned32

Values & Constraints

No enumerated values or constraints recorded.

Related Objects

Sibling Objects