pktcSigPulseSignalFrequency

PKTC-EXCENTIS-SIG-MIB · .1.3.6.1.4.1.7432.2.1.1.20.1.2

Object

column r/w Hertz Enumeration
This object is only applicable to the initialRing, 
enableMeterPulse, and meterPulseBurst signal type. This 
object identifies the frequency of the generated signal. 
The following table defines the default values for this 
object depending on signal type: 
pktcSigPulseSignalType     Default 
              
              
initialRing                25 
enableMeterPulse           16000 
meterPulseBurst            16000 
The value of twentyfive MUST only be used for the 
initialRing signal type. The values of twelvethousand and 
sixteenthousand MUST only be used for enableMeterPulse and 
meterPulseBurst signal types. An attempt to set this 
object while the value of pktcSigPulseSignalType is not 
initialRing,enableMeterPulse, or meterPulseBurst will 
result in an 'inconsistent value' error.

Context

MIB
PKTC-EXCENTIS-SIG-MIB
OID
.1.3.6.1.4.1.7432.2.1.1.20.1.2
Type
column
Access
readwrite
Status
current
Units
Hertz
Parent
pktcSigPulseSignalEntry
Table
pktcSigPulseSignalTable
Siblings
5

Syntax

Hertz Enumeration

Values & Constraints

Enumerated Values
1twentyfive
2twelvethousand
3sixteenthousand

Related Objects