pktcSigPulseSignalDuration
PKTC-EXCENTIS-SIG-MIB ·
.1.3.6.1.4.1.7432.2.1.1.20.1.4
Object
column
r/w
Milliseconds Unsigned32
This object specifies the pulse duration for each
signal type. In addition, the MTA must accept the values
in the incremental steps specific for each signal type.
The following table defines the default values and the
incremental steps for this object depending on the signal
type.
pktcSigPulseSignaltype Default (ms) Increment (ms)
initialRing 200 50
pulseLoopClose 200 10
pulseLoopOpen 200 10
enableMeterPulse 150 10
meterPulseBurst 150 10
pulseNoBattery 200 10
pulseNormalPolarity 200 10
pulseReducedBattery 200 10
pulseReversePolarity 200 10
An attempt to set this object to a value that does not
fall on one of the increment boundaries, or on the wrong
increment boundary for the specific signal type will
result in an 'inconsistent value' error.
Context
- MIB
- PKTC-EXCENTIS-SIG-MIB
- OID
.1.3.6.1.4.1.7432.2.1.1.20.1.4- Type
- column
- Access
- readwrite
- Status
- current
- Units
- Milliseconds
- Parent
- pktcSigPulseSignalEntry
- Table
- pktcSigPulseSignalTable
- Siblings
- 5
Syntax
Milliseconds Unsigned32
Values & Constraints
Object Constraints
range: 0-5000
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| pktcSigPulseSignalType There are nine types of international pulse signals. These
signals are defined as follows:
initial ring
pulse loop close
pulse loop open
enable meter pulse
meter pulse burst… | column | Enumeration | .1.3.6.1.4.1.7432.2.1.1.20.1.1 |
| pktcSigPulseSignalFrequency This object is only applicable to the initialRing,
enableMeterPulse, and meterPulseBurst signal type. This
object identifies the frequency of the generated signal.
The followin… | column | Hertz Enumeration | .1.3.6.1.4.1.7432.2.1.1.20.1.2 |
| pktcSigPulseSignalDbLevel This object is only applicable to the enableMeterPulse and
meterPulseBurst signal types. This is the decibel level
for each frequency at which tones could be generated at
the a… | column | dBm Integer32 | .1.3.6.1.4.1.7432.2.1.1.20.1.3 |
| pktcSigPulseSignalPulseInterval This object specifies the repeat interval, or the period
for each signal type. In addition, the MTA must accept
the values in the incremental steps specific for each
signal typ… | column | Milliseconds Unsigned32 | .1.3.6.1.4.1.7432.2.1.1.20.1.5 |
| pktcSigPulseSignalRepeatCount This object specifies how many times to repeat a pulse.
This object is not used by the enableMeterPulse signal
type and as such must have a value o… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.7432.2.1.1.20.1.6 |