pktcSigDevVmwiDTASAfterLR

PKTC-EXCENTIS-SIG-MIB · .1.3.6.1.4.1.7432.2.1.1.30

Object

scalar r/w Milliseconds Unsigned32
This object specifies the delay between the end of the  
Line Reversal and the start of the Dual Tone Alert Signal 
(DT-AS) for VMWI information. This object is only used 
when pktcSigDevVmwiMode is lrAsETS. The following table 
defines the default values for this object depending on 
signal type: 
pktcSigDevVmwiMode     Default 
dtAsETS                not used 
rpAsETS                not used 
lrAsETS                250 ms 
An attempt to set this object while the value of 
pktcSigDevVmwiMode is not lrAsETS will result in an 
'inconsistent value' error.

Context

MIB
PKTC-EXCENTIS-SIG-MIB
OID
.1.3.6.1.4.1.7432.2.1.1.30
Type
scalar
Access
readwrite
Status
current
Units
Milliseconds
Parent
pktcSigDevConfigObjects
Siblings
32

Syntax

Milliseconds Unsigned32

Values & Constraints

Object Constraints
range: 50-655

Related Objects

Sibling Objects