pktcSigDevToneFreqRepeatCount

PKTC-EXCENTIS-SIG-MIB · .1.3.6.1.4.1.7432.2.1.1.33.1.11

Object

column r/w Unsigned32
This MIB Object indicates the number of times 
to repeat the cadence cycle represented by the  
on/off durations (refer to the MIB Objects  
              
              
pktcSigDevToneFreqOnDuration and  
pktcSigDevToneFreqOffDuration).  
              
Setting this object may result in a tone duration  
longer or shorter than the overall signal duration  
specified by the time out (TO) object for the  
corresponding tone type. If the value of this MIB 
Object indicates a longer duration than the  
specified by the TO, the latter overrules the former 
and the desired tone duration will be truncated according 
to the TO. 
              
However, if the repeat count results in a shorter 
tone duration than the signal duration specified by 
the TO, the tone duration defined by the repeat count 
takes precedence over the TO and will end the signal 
event. In this case, the TO represents a time not to 
be exceeded for the signal. It is recommended to 
ensure proper telephony signaling that the TO 
duration setting should always be longer than the 
desired repeat count time duration. A value of zero 
means the tone sequence is to be played once but not 
repeated.