pktcNcsEndPntConfigMinHookFlash
PKTC-EXCENTIS-SIG-MIB ·
.1.3.6.1.4.1.7432.2.1.2.1.1.32
Object
column
r/w
Milliseconds Unsigned32
This is the minimum time a line needs to be on hook for a valid hook flash. The value of this object MUST be greater than the value of pktcNcsEndPntConfigPulseDialMaxBreakTime. The value of pktcNcsEndPntConfigMinHookFlash MUST be less than pktcNcsEndPntConfigMaxHookFlash. This object MUST only be set via the configuration file during the provisioning process. Furthermore, given the possibility for the 'pulse dial' and 'hook flash' to overlap, the value of this object MUST be greater than the value contained by the MIB Object pktcNcsEndPntConfigPulseDialMaxMakeTime.
Context
- MIB
- PKTC-EXCENTIS-SIG-MIB
- OID
.1.3.6.1.4.1.7432.2.1.2.1.1.32- Type
- column
- Access
- readwrite
- Status
- current
- Units
- Milliseconds
- Parent
- pktcNcsEndPntConfigEntry
Syntax
Milliseconds Unsigned32
Values & Constraints
Object Constraints
range: 20-1550