pktcNcsEndPntConfigMinHookFlash

PKTC-EXCENTIS-SIG-MIB · .1.3.6.1.4.1.7432.2.1.2.1.1.32

Object

column r/w Milliseconds Unsigned32
This is the minimum time a line needs to be on hook for a 
valid hook flash. The value of this object MUST be 
greater than the value of 
pktcNcsEndPntConfigPulseDialMaxBreakTime. The value of 
pktcNcsEndPntConfigMinHookFlash MUST be less than 
pktcNcsEndPntConfigMaxHookFlash. This object MUST only be 
set via the configuration file during the provisioning 
process. 
   Furthermore, given the possibility for the 'pulse dial'  
   and 'hook flash' to overlap, the value of this object 
MUST                 
   be greater than the value contained by the MIB Object  
   pktcNcsEndPntConfigPulseDialMaxMakeTime.

Context

MIB
PKTC-EXCENTIS-SIG-MIB
OID
.1.3.6.1.4.1.7432.2.1.2.1.1.32
Type
column
Access
readwrite
Status
current
Units
Milliseconds
Parent
pktcNcsEndPntConfigEntry
Table
pktcNcsEndPntConfigTable
Siblings
37

Syntax

Milliseconds Unsigned32

Values & Constraints

Object Constraints
range: 20-1550