ons15501InputOpticalPowerTrigger

ONS15501-MIB · .1.3.6.1.4.1.1869.11.11.2.3

Object

scalar r/w dBInteger32
Trigger defines the max deviation allowed from the
mean, without an alarm being generated. Once an
alarm is generated, it is not cleared until the
input optical power falls back within 90% of the 
trigger value from the mean. Please also refer
to ons15501InputOpticalPowerMean above.

Context

MIB
ONS15501-MIB
OID
.1.3.6.1.4.1.1869.11.11.2.3
Type
scalar
Access
readwrite
Status
current
Units
dB
Parent
ons15501Attr
Groups
2

Scalars have one instance, identified by the .0 suffix.

Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'ONS15501-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ONS15501-MIB::ons15501InputOpticalPowerTrigger.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'ONS15501-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'ONS15501-MIB::ons15501InputOpticalPowerTrigger'

Syntax

dBInteger32

Values & Constraints

Object Constraints
range: 0-200