eventPdStatus
OMNITRON-TRAP-MIB ·
.1.3.6.1.4.1.7342.6.13
Object
scalar
Bits
A vector of bits that indicates the PoE PD Status
A bit set to '1' indicates the specific errored condition. A bit set to
'0' indicates the specific errored condition is not present
bNoPdDetected(0) No PD device found for a PSE enabled port
bIllegalClassification(1) PD device classification is illegal or
unrecognized
bOverCurrent(2) PD device requesting more power than
was determined during classification
bBrownOut(3) PD device are experiencing brown-out since
PSE cannot source requested power
bInsufficientPower(4) PD device is not powered since power
classification cannot be met
bHeartbeatLost(5) PD device with heartbeat enabled is not
responding with heartbeat
Context
- MIB
- OMNITRON-TRAP-MIB
- OID
.1.3.6.1.4.1.7342.6.13- Type
- scalar
- Access
- notifyonly
- Status
- current
- Parent
- omnitronNotificationObjects
Syntax
Bits
Values & Constraints
Enumerated Values
0 | bNoPdDetected |
1 | bIllegalClassification |
2 | bOverCurrent |
3 | bBrownOut |
4 | bInsufficientPower |
5 | bHeartbeatLost |