OMNITRON-TRAP-MIB

        Omnitron Trap MIB for use with v5.3 iConverter Management Modules
and NetOutlook
        
Copyright 2017 Omnitron Systems Technology, Inc.
All rights reserved
    
Source file
OMNITRON-TRAP-MIB
Last revised
Identity
omnitronTrapMIB
Base OID
1.3.6.1.4.1.7342.12
Imported Objects
mefSoamAisStatsInStatus (no object page) mefSoamAisStatsOutStatus (no object page) mefSoamLckStatsInStatus (no object page) mefSoamLckStatsOutStatus (no object page)
DS1-MIB dsx1LineStatus dsx1LineStatusLastChange
OMNITRON-TC-MIB icAgent omnitron OstErpsRingStatus OstIpAddr OstModeType OstPortClockType
SNMPv2-CONF MODULE-COMPLIANCE (no object page) NOTIFICATION-GROUP (no object page) OBJECT-GROUP (no object page)
SNMPv2-SMI Counter64 Integer32 IpAddress MODULE-IDENTITY (no object page) NOTIFICATION-TYPE (no object page) OBJECT-TYPE (no object page) Unsigned32
SNMPv2-TC DateAndTime DisplayString
Net-SNMP examples using the omnitron MIB directory Show commands

These commands use the standard Observium installation path and load the selected MIB variant before the RFC and Net-SNMP directories.

Translate the module identity
/usr/bin/snmptranslate -Pud -Ir -On -m 'OMNITRON-TRAP-MIB' -M '/opt/observium/mibs/omnitron:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'OMNITRON-TRAP-MIB::omnitronTrapMIB'
Walk the MIB subtree
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'OMNITRON-TRAP-MIB' -M '/opt/observium/mibs/omnitron:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'OMNITRON-TRAP-MIB::omnitronTrapMIB'
How SNMP, Net-SNMP, MIB paths, and variants work
Objects (58)
.1.3.6.1.4.1.7342.0
.1.3.6.1.4.1.7342.1.10
Integer32
.1.3.6.1.4.1.7342.1.2
Integer32
.1.3.6.1.4.1.7342.1.3
Integer32
.1.3.6.1.4.1.7342.1.4
.1.3.6.1.4.1.7342.1.5
OctetString
.1.3.6.1.4.1.7342.1.7
.1.3.6.1.4.1.7342.1.9
.1.3.6.1.4.1.7342.12
.1.3.6.1.4.1.7342.12.1
.1.3.6.1.4.1.7342.12.1.1
.1.3.6.1.4.1.7342.12.1.1.1
.1.3.6.1.4.1.7342.12.1.1.1.1
Enumeration
.1.3.6.1.4.1.7342.12.1.1.1.2
Enumeration
.1.3.6.1.4.1.7342.12.1.1.1.3
Enumeration
.1.3.6.1.4.1.7342.12.1.1.1.4
Enumeration
.1.3.6.1.4.1.7342.12.1.2
.1.3.6.1.4.1.7342.12.1.3
.1.3.6.1.4.1.7342.12.1.3.1
.1.3.6.1.4.1.7342.12.1.3.1.1
.1.3.6.1.4.1.7342.12.1.3.1.2
OctetString
.1.3.6.1.4.1.7342.12.1.3.1.3
.1.3.6.1.4.1.7342.12.1.3.1.4
OctetString
.1.3.6.1.4.1.7342.12.1.3.1.5
.1.3.6.1.4.1.7342.12.1.4
.1.3.6.1.4.1.7342.12.1.5
.1.3.6.1.4.1.7342.12.1.5.1
.1.3.6.1.4.1.7342.12.1.5.1.1
.1.3.6.1.4.1.7342.12.1.5.1.2
OctetString
.1.3.6.1.4.1.7342.12.1.5.1.3
.1.3.6.1.4.1.7342.12.1.5.1.4
.1.3.6.1.4.1.7342.12.1.5.1.5
OctetString
.1.3.6.1.4.1.7342.12.1.5.1.6
Bits
.1.3.6.1.4.1.7342.12.1.6
.1.3.6.1.4.1.7342.12.2
.1.3.6.1.4.1.7342.12.2.1
.1.3.6.1.4.1.7342.12.2.2
.1.3.6.1.4.1.7342.6
Unsigned32
.1.3.6.1.4.1.7342.6.1
.1.3.6.1.4.1.7342.6.10
Unsigned32
.1.3.6.1.4.1.7342.6.11
Enumeration
.1.3.6.1.4.1.7342.6.12
Bits
.1.3.6.1.4.1.7342.6.13
Enumeration
.1.3.6.1.4.1.7342.6.14
.1.3.6.1.4.1.7342.6.15
.1.3.6.1.4.1.7342.6.16
Unsigned32
.1.3.6.1.4.1.7342.6.17
Unsigned32
.1.3.6.1.4.1.7342.6.18
.1.3.6.1.4.1.7342.6.19
Unsigned32
.1.3.6.1.4.1.7342.6.2
.1.3.6.1.4.1.7342.6.20
Integer32
.1.3.6.1.4.1.7342.6.3
.1.3.6.1.4.1.7342.6.4
Integer32
.1.3.6.1.4.1.7342.6.5
.1.3.6.1.4.1.7342.6.6
.1.3.6.1.4.1.7342.6.7
.1.3.6.1.4.1.7342.6.8
Enumeration
.1.3.6.1.4.1.7342.6.9
Dependencies (9) 5 direct · 4 transitive Show tree and compile order Hide dependency details

Each imported module is resolved in the importing module's source directory first, then through the normal default-variant rules.

Dependency tree
Dependency-first compile order
  1. SNMPv2-SMIrfc
  2. SNMPv2-TCrfc
  3. IANAifType-MIBrfc
  4. SNMPv2-CONFrfc
  5. SNMPv2-MIBrfc
  6. IF-MIBrfc
  7. PerfHist-TC-MIBrfc
  8. DS1-MIBrfc
  9. OMNITRON-TC-MIBomnitron
  10. OMNITRON-TRAP-MIBomnitronselected
Conformance Groups (3)
icModcoldstrt icModsftreset icModlinkdown icModlinkup icModdipsw icModsoftcfg icModovertemp icModvoltrnge icModpwrremv icModpwrapply icAuthfail icChasnew icChasgone icModremove icPriAct icPriDis icSecAct icSecDis icTelStart icTelStop icFTPStart icFTPStop icStnAct icStnDis icPwdExceeded icROMchecksum icROMFileType icROMProgFail icROMFileChecksum icModuleFlashProgramComplete icDyingGasp icKeepAlive icVlanCfgChange icAISdetected icPRBSdetected icChassisMastershipAcquired icSecureModeChange icChassisMastershipRelinquished icSFPDeviceInserted icSFPDeviceRemoved icAHEventNotificationGenerated icAHEventNotificationReceived icContactStatusChange icAHLinkFaultReceived icAHCriticalEventGenerated icAHCriticalEventReceived icAHRemoteDyingGasp icResource icLoopbackReplyReceived icLoopbackReplyLost icCfmFaultAlarm icCfmLoopBackComplete icCfmLinkTraceComplete icCfmMepUp icCfmMepDown icCfmMepCrossConnect icCfmLoop icCfmConfigError icCfmAllMepsUp icCfmMepUnknown icSfpTxLow icSfpTxHigh icSfpBiasLow icSfpBiasHigh icSfpVcc3Low icSfpVcc3High icSfpTempLow icSfpTempHigh icSfpAux2Low icSfpAux2High icSfpAux1Low icSfpAux1High icSfpRxLow icSfpRxHigh icSfpVcc2Low icSfpVcc2High icSfpVcc5Low icSfpVcc5High icLineChange icConfigChange icLoopbackActivation icLoopbackDeactivation icTimingError icFramingOverrun icDataUnderrun icRemoteFound icHardwareFault icRemoteLost icRemoteError icRemoteGood icExternalClockLost icSerStart icSerStop icSFPOverPower icRemoteTestActivation icRemoteTestDeactivation icLocalTestActivation icLocalTestDeactivation icAuthSshFail icSshStart icSshStop icFileCorrupt icProtectionSwitch icProtectionMismatch icFanNoRpm icFanHighRpm icFpgaFailure icFanNormalRpm ic1588SyncGained ic1588SyncLost ic1588PrimaryActive ic1588PrimaryInactive ic1588SecondaryActive ic1588SecondaryInactive icSyncEthernetSourceGained icSyncEthernetSourceLost icSyncEthernetHoldoverLost icAisAlarm icLckAlarm icThresholdCrossing icThresholdCrossingClear icTdmClockStatusChange icTdmEthernetFrameCount icSfpReceiveCdrLossLock icSfpTransmitCdrLossLock icDpoeStageWarningAlarm icDpoeStageFailAlarm icSfpReceiveCdrGainedLock icSfpTransmitCdrGainedLock icModNormalTemp icModNormalVoltage icPortNormalData icLinkOamRemoteLinkNormal icLinkOamLocalLinkNormal icSfpNormal icPoEPdStatus icProbePriorityChange icAuthFtpFail icAclDeny icLinkOamDiscoveryComplete icLinkOamDiscoveryLost icServiceActivationTestInitiated icServiceActivationTestCompleted icUtilizationThresholdViolation icUtilizationThresholdNormal icLoopPreventionBlock icLoopPreventionClear icAuthTelnetFail icRingProtectStateChange
A collection of Omnitron notifications.
.1.3.6.1.4.1.7342.12.2.2.1
A collection of Omnitron notification objects.
.1.3.6.1.4.1.7342.12.2.2.2
A collection of Omnitron trap configurat objects.
.1.3.6.1.4.1.7342.12.2.2.3
Compliance Statements (1)

OID .1.3.6.1.4.1.7342.12.2.1.1
The compliance statement for the Omnitron Protocol MIB.
Required groups
Notifications / Traps (149)
NameOIDDescription
.1.3.6.1.4.1.7342.0.1
Module Cold Start - a module has been plugged into a chassis
.1.3.6.1.4.1.7342.0.10
Module Power Applied - A power supply's cord was not supplying power
and now it is. The supply is generating voltage. (for chassis with
multiple supplies)
.1.3.6.1.4.1.7342.0.100
Remote Unit Lost.
.1.3.6.1.4.1.7342.0.101
Remote Unit Error Detected.
.1.3.6.1.4.1.7342.0.102
Remote Unit Good Detected.
.1.3.6.1.4.1.7342.0.103
The external clock source has been lost.
.1.3.6.1.4.1.7342.0.104
Serial Session Started.
.1.3.6.1.4.1.7342.0.105
Serial Session Stopped.
.1.3.6.1.4.1.7342.0.106
SFP is consuming too much power.
.1.3.6.1.4.1.7342.0.107
Remote Test Activation - test mode entered on remote device.
.1.3.6.1.4.1.7342.0.108
Remote Test Deactivation - test mode exited on remote device.
.1.3.6.1.4.1.7342.0.109
Local Test Activation - test mode entered on local device.
.1.3.6.1.4.1.7342.0.11
Data Manager Authentication Failure - The name and password supplied to
the SNMP agent did not match the ones configured into the data
manager's user-settings.
.1.3.6.1.4.1.7342.0.110
Local Test Deactivation - test mode exited on local device.
.1.3.6.1.4.1.7342.0.111
SSH Authentication Failure - Authentication type/password did not match
configured setting.
.1.3.6.1.4.1.7342.0.112
SSH Session Started - The management module has detected that a SSH
session has started.
.1.3.6.1.4.1.7342.0.113
SSH Session Stopped - The management module has detected that a SSH
session has stopped.
.1.3.6.1.4.1.7342.0.114
Configuration File Corrupted - The management module has detected a
corrupted configuration file.
.1.3.6.1.4.1.7342.0.115
Protection Switch - trap generated when a protection switch occurs.
.1.3.6.1.4.1.7342.0.116
Protection Configuration Mismatch - trap generated when a protection
configuration mismatch occurs.
.1.3.6.1.4.1.7342.0.117
Fan Rotation Not Detected - Detected no or low RPMs generated from the
fan.
.1.3.6.1.4.1.7342.0.118
Fan Rotation High Threshold - Detected fan rotation speed is high.
.1.3.6.1.4.1.7342.0.119
FPGA Failure - FPGA initialization failure.
.1.3.6.1.4.1.7342.0.120
Fan Rotation Normal - Detected normal fan rotation speed
.1.3.6.1.4.1.7342.0.121
1588 Synchronization - Synchronization with 1588 master is gained
.1.3.6.1.4.1.7342.0.122
1588 Synchronization - Synchronization with 1588 master is lost
.1.3.6.1.4.1.7342.0.123
1588 Master - Primary Master is Active
.1.3.6.1.4.1.7342.0.124
1588 Master - Primary Master Inactive
.1.3.6.1.4.1.7342.0.125
1588 Master - Secondary Master Active
.1.3.6.1.4.1.7342.0.126
1588 Master - Secondary Master Inactive
.1.3.6.1.4.1.7342.0.127
Synchronous Ethernet - Synchronous Ethernet Clock Source Gained
.1.3.6.1.4.1.7342.0.128
Synchronous Ethernet - Synchronous Ethernet Clock Source Lost
.1.3.6.1.4.1.7342.0.129
Synchronous Ethernet - Synchronous Ethernet Clock Holdover Lost
.1.3.6.1.4.1.7342.0.13
Chassis New - a new chassis has been added to the system
trapchassis trapslot trapcode trapip trapmoduledescription trapmodetype trapAgMdIndex trapAgMaIndex trapAgMepId mefSoamAisStatsInStatus (unresolved reference) mefSoamAisStatsOutStatus (unresolved reference) trapIpString
.1.3.6.1.4.1.7342.0.130
AIS State Change - OAM AIS reception or transmission state has changed
trapchassis trapslot trapcode trapip trapmoduledescription trapmodetype trapAgMdIndex trapAgMaIndex trapAgMepId mefSoamLckStatsInStatus (unresolved reference) mefSoamLckStatsOutStatus (unresolved reference) trapIpString
.1.3.6.1.4.1.7342.0.131
LCK State Change - OAM ETH-LCK reception or transmission state has
changed
.1.3.6.1.4.1.7342.0.132
Threshold Crossing - Performance Criteria Measurement not met. This
trap should be generated at most once every 5 minutes.
.1.3.6.1.4.1.7342.0.133
Threshold Crossing - Performance Criteria Measurement met
.1.3.6.1.4.1.7342.0.134
TDM Clock Status Change - Status of TDM recovery clock changed
.1.3.6.1.4.1.7342.0.135
TDM Ethernet Frame Count - Incorrect number of Ethernet frames
.1.3.6.1.4.1.7342.0.136
SFP/XFP Receive CDR Loss of Lock
.1.3.6.1.4.1.7342.0.137
SFP/XFP transmitted loses CDR lock
.1.3.6.1.4.1.7342.0.138
DPoE Stage warning alarm. Alarm is sent when the alarm state changes to
either set or clear. Only one stage warning alarm can be set at one
time.
.1.3.6.1.4.1.7342.0.139
DPoE Stage failure alarm. Alarm is sent when the alarm state changes to
either set or clear. Only one stage fail alarm can be set at one time.
.1.3.6.1.4.1.7342.0.14
Chassis Gone - a chassis has been removed from the system
.1.3.6.1.4.1.7342.0.140
SFP/XFP receiver gained CDR lock
.1.3.6.1.4.1.7342.0.141
SFP/XFP transmitted gained CDR lock
.1.3.6.1.4.1.7342.0.142
Module normal temperature
.1.3.6.1.4.1.7342.0.143
Module normal voltage range
.1.3.6.1.4.1.7342.0.144
Module data detected
.1.3.6.1.4.1.7342.0.145
802.3ah remote link normal
.1.3.6.1.4.1.7342.0.146
802.3ah local link normal
.1.3.6.1.4.1.7342.0.147
XFP/SFP normal
.1.3.6.1.4.1.7342.0.148
PoE PD Status Change
.1.3.6.1.4.1.7342.0.149
Generated when a Y.1731 probe priority changes.

Currently this is only valid for DMR reception.

'trapcode' indicates the probe instance number.
.1.3.6.1.4.1.7342.0.150
FTP Authentication Failure - Authentication type/password did not match
configured setting.
.1.3.6.1.4.1.7342.0.151
ACL denial. Access is not allowed by configured ACL's. This trap
only to be generated at most once a minute.
.1.3.6.1.4.1.7342.0.152
The module has detected Link OAM discovery completion on a port and is
generated when discovery completes.
.1.3.6.1.4.1.7342.0.153
The module has detected Link OAM discovery has been lost on a port and
is generated when a Link OAM discovery had previously been completed on
a port, but is now lost.
.1.3.6.1.4.1.7342.0.154
The module has initiated a Service Activation Test: either a 2544 or
ITU-T Y.1564 test.
.1.3.6.1.4.1.7342.0.155
The module has completed a Service Activation Test: either a 2544 or
ITU-T Y.1564 test.
.1.3.6.1.4.1.7342.0.156
The module has detected a utilization threshold violation on a port or
a bandwidth profile. trapcode of 1-99 indicate a port threshold
violation. trapcode of 101-164 indicate the bandwidth profile number

This trap can only be generated if the threshold has not been
violated for 5 seconds.
.1.3.6.1.4.1.7342.0.157
The module has detected a utilization threshold violation has cleared
on a port or a bandwidth profile number.

This trap can only be generated once a threshold violation has been
cleared for 5 seconds.
.1.3.6.1.4.1.7342.0.158
The module has detected loop condition and a loop prevention block on
the port has occurred.
.1.3.6.1.4.1.7342.0.159
The module has detected that a loop condition has been cleared and
the loop prevention block on the port has been removed.
.1.3.6.1.4.1.7342.0.16
Module Remove - a module has been removed from chassis
.1.3.6.1.4.1.7342.0.160
Telnet Authentication Failure - Telnet user name and/or password did not
match.
.1.3.6.1.4.1.7342.0.161
The module has detected a Ring Protection port state change.
.1.3.6.1.4.1.7342.0.17
Primary Link up
.1.3.6.1.4.1.7342.0.18
Primary Link down
.1.3.6.1.4.1.7342.0.19
Secondary Link up
.1.3.6.1.4.1.7342.0.2
Module Reset - the module received a reset command from the chassis
data manager
.1.3.6.1.4.1.7342.0.20
Secondary Link down
.1.3.6.1.4.1.7342.0.21
Telnet Session Started
.1.3.6.1.4.1.7342.0.22
Telnet Session Stopped
.1.3.6.1.4.1.7342.0.23
FTP Session Started
.1.3.6.1.4.1.7342.0.24
FTP Session Stopped
.1.3.6.1.4.1.7342.0.25
Secondary Link Standby Up
.1.3.6.1.4.1.7342.0.26
Secondary Link Standby Down
.1.3.6.1.4.1.7342.0.27
Password Count Exceeded
.1.3.6.1.4.1.7342.0.28
Flash checksum error
.1.3.6.1.4.1.7342.0.29
Flash file type incorrect
.1.3.6.1.4.1.7342.0.3
Module Link Down - the module went from a link to a no link condition
.1.3.6.1.4.1.7342.0.30
Flash program failure
.1.3.6.1.4.1.7342.0.31
Flash file transmission error
.1.3.6.1.4.1.7342.0.32
Module programming completed OK
.1.3.6.1.4.1.7342.0.33
Power failure detected, system shutting down
.1.3.6.1.4.1.7342.0.34
Periodic trap to let management applications know device is still
active
.1.3.6.1.4.1.7342.0.35
Module VLAN information has been changed
.1.3.6.1.4.1.7342.0.36
AIS Detected
.1.3.6.1.4.1.7342.0.37
PRBS Detected
.1.3.6.1.4.1.7342.0.39
Management module has acquired mastership of the backplane
.1.3.6.1.4.1.7342.0.4
Module Link Up - the module went from no link to a link condition
.1.3.6.1.4.1.7342.0.40
Module has switched secure mode
trapcode 0: secure -> normal (NMM master)
trapcode 1: normal -> secure (NMM master)
trapcode 2: secure -> normal (secure proxy)
trapcode 3: normal -> secure (secure proxy)
trapcode 4: secure -> normal (secure slave)
trapcode 5: normal -> secure (secure slave)
.1.3.6.1.4.1.7342.0.41
Management module has relinquished mastership of the backplane
.1.3.6.1.4.1.7342.0.42
A SFP Device Inserted
.1.3.6.1.4.1.7342.0.43
A SFP Device Removed
.1.3.6.1.4.1.7342.0.44
AH Link Event has been generated
.1.3.6.1.4.1.7342.0.45
AH Link Event has been received
.1.3.6.1.4.1.7342.0.46
Contact closure status change detected
.1.3.6.1.4.1.7342.0.47
A link fault has been received over AH connection
.1.3.6.1.4.1.7342.0.48
A critical event has been generated
.1.3.6.1.4.1.7342.0.49
A critical event has been received
.1.3.6.1.4.1.7342.0.5
Module Dip Switch Change - the dip switches on the module were changed
.1.3.6.1.4.1.7342.0.50
Power failure detected from remote partner, system shutting down
.1.3.6.1.4.1.7342.0.51
Generated when an internal resource is fully allocated. Specific
resource is defined by the Trap code.
.1.3.6.1.4.1.7342.0.52
Generated when the T1/E1, T3/E3 remote module responds to a loopback
request
.1.3.6.1.4.1.7342.0.53
Generated when the T1/E1, T3/E3 remote module stops sending a loopback
reply
.1.3.6.1.4.1.7342.0.54
Generated when an 802.1ag MEP has a persistent defect condition,
trapcode has the port number
.1.3.6.1.4.1.7342.0.55
Generated when an 802.1ag loopback command has completed.
.1.3.6.1.4.1.7342.0.56
Generated when an 802.1ag Link Trace command has completed.
.1.3.6.1.4.1.7342.0.57
Generated when an 802.1ag MEP is discovered, service is restored, or
status of report port changes.
.1.3.6.1.4.1.7342.0.58
Generated when an 802.1ag MEP timeout occurs.
.1.3.6.1.4.1.7342.0.59
Generated when an 802.1ag service ID does not match the VLAN or is at
a lower MD level.
.1.3.6.1.4.1.7342.0.6
Module Configuration Change - the module configuration was changed by
external software and the hardware configuration may no longer
reflect its true state
.1.3.6.1.4.1.7342.0.60
Generated when an 802.1ag MEP receives its own CCM or MEPID.
.1.3.6.1.4.1.7342.0.61
Generated when an 802.1ag MEP receives an incorrect CCM.
.1.3.6.1.4.1.7342.0.62
Generated when all 802.1ag expected MEPs are up in time.
.1.3.6.1.4.1.7342.0.64
Generated when an 802.1ag CCM is received from an unexpected MEP.
.1.3.6.1.4.1.7342.0.7
Module Over Temperature - for modules with temperature sensing
capabilities this trap indicates the temperature is over the acceptable
limits for the module
.1.3.6.1.4.1.7342.0.73
Generated when the measured Tx power is less than the low threshold.
.1.3.6.1.4.1.7342.0.74
Generated when the measured Tx power is greater than the high
threshold.
.1.3.6.1.4.1.7342.0.75
Generated when the measured bias voltage is less than the low
threshold.
.1.3.6.1.4.1.7342.0.76
Generated when the measured bias voltage is greater than the high
threshold.
.1.3.6.1.4.1.7342.0.77
Generated when the measured voltage is less than the low threshold.
.1.3.6.1.4.1.7342.0.78
Generated when the measured voltage is greater than the high threshold.
.1.3.6.1.4.1.7342.0.79
Generated when the measured temperature is less than the low threshold.
.1.3.6.1.4.1.7342.0.8
Module Voltage Range - for modules with voltage sensing capabilities
this trap indicates the voltage is outside of the acceptable limits
defined for the voltage being sensed
.1.3.6.1.4.1.7342.0.80
Generated when the measured temperature is greater than the high
threshold.
.1.3.6.1.4.1.7342.0.81
Generated when the measured Aux 2 value is less than the low threshold.
.1.3.6.1.4.1.7342.0.82
Generated when the measured Aux 2 value is greater than the high
threshold.
.1.3.6.1.4.1.7342.0.83
Generated when the measured Aux 1 value is less than the low threshold.
.1.3.6.1.4.1.7342.0.84
Generated when the measured Aux 1 value is greater than the high
threshold.
.1.3.6.1.4.1.7342.0.85
Generated when the measured Rx power is less than the low threshold.
.1.3.6.1.4.1.7342.0.86
Generated when the measured Rx power is greater than the high
threshold.
.1.3.6.1.4.1.7342.0.87
Generated when the measured voltage is less than the low threshold.
.1.3.6.1.4.1.7342.0.88
Generated when the measured voltage is greater than the high threshold.
.1.3.6.1.4.1.7342.0.89
Generated when the measured voltage is less than the low threshold.
.1.3.6.1.4.1.7342.0.9
Module Power Removed - A power supply's cord is no longer supplying
power to it and the supply is no longer generating voltage. (For
chassis with multiple supplies)
.1.3.6.1.4.1.7342.0.90
Generated when the measured voltage is greater than the high threshold.
.1.3.6.1.4.1.7342.0.91
OST equivalent of the DS1 MIB dsx1LineStatusChange.
.1.3.6.1.4.1.7342.0.92
Configuration change has been committed to flash.
.1.3.6.1.4.1.7342.0.93
Loopback Activation - loopback mode entered on remote device.
.1.3.6.1.4.1.7342.0.94
Loopback Deactivation - normal mode entered on remote device.
.1.3.6.1.4.1.7342.0.95
Timing Error or Clock Slip.
.1.3.6.1.4.1.7342.0.96
Data Framing Overrun.
.1.3.6.1.4.1.7342.0.97
Data Framing Under run.
.1.3.6.1.4.1.7342.0.98
Remote Unit Found.
.1.3.6.1.4.1.7342.0.99
Module Hardware Failure