ostElpsInstanceCfgWorkingMaIndex
OMNITRON-G8031-MIB ·
.1.3.6.1.4.1.7342.10.1.3.2.1.18
Object
This object specifies the Working MEP ELPS instance maintenance
association index.
It is mandatory to be configured with a valid value if
ostElpsInstanceCfgScopeType is 'mep'.
The value is ignored for ostElpsInstanceCfgScopeType 'port' or 'evc'.
This object can only be written at row creation time and cannot be
modified once it has been created.
Context
- MIB
- OMNITRON-G8031-MIB
- OID
.1.3.6.1.4.1.7342.10.1.3.2.1.18- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- ostElpsInstanceCfgEntry
- Groups
- 1
Net-SNMP examples
How SNMP and these commands workWalk the column to discover its indexed instances, or supply every index to read one instance.
Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'OMNITRON-G8031-MIB' -M '/opt/observium/mibs/omnitron:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'OMNITRON-G8031-MIB::ostElpsInstanceCfgWorkingMaIndex'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'OMNITRON-G8031-MIB' -M '/opt/observium/mibs/omnitron:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'OMNITRON-G8031-MIB::ostElpsInstanceCfgWorkingMaIndex.<ostElpsInstanceCfgIndex>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'OMNITRON-G8031-MIB' -M '/opt/observium/mibs/omnitron:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'OMNITRON-G8031-MIB::ostElpsInstanceCfgWorkingMaIndex'
Syntax
- Source
- SNMPv2-SMIUnsigned32
- Base type
Unsigned32
Values & Constraints
Type Constraints
range: 0..4294967295
Conformance
Member of