ostElpsInstanceCfgManualMode
OMNITRON-G8031-MIB ·
.1.3.6.1.4.1.7342.10.1.3.2.1.25
Object
column
r/w
Enumeration
This object selects the protection instance manual mode. When written the
indicated manual mode is selected.
nocommand(0) no command is indicated, read-only value only, write of
this value returns an error
lockout(1) sets lockout of protection
freeze(2) sets freeze state
clearfreeze(3) clears freeze state
force(4) force switch from normal working link to protection link
protect(5) manual switch from working to protection link
working(6) manual switch from protection to working link
exercise(7) exercise APS protocol
clear(8) clear to normal operation
This object can be written/modified after row creation time.
Context
- MIB
- OMNITRON-G8031-MIB
- OID
.1.3.6.1.4.1.7342.10.1.3.2.1.25- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- ostElpsInstanceCfgEntry
Syntax
Enumeration
Values & Constraints
Enumerated Values
0 | nocommand |
1 | lockout |
2 | freeze |
3 | clearfreeze |
4 | force |
5 | protect |
6 | working |
7 | exercise |
8 | clear |