connSoftPvcTable

NEC-MIB · .1.3.6.1.4.1.119.2.3.14.9.4.5

Object

table mandatory
This table include all entries to Soft-PVPC/PVCC 
currently available between the lines or the line and 
CPU port of the switch.  Also, this table is used to 
set or delete Soft-PVPC/PVCC.  The operable 
connection form between Soft-PVPC/PVCC is bi-
directional point-to-point only.
          
The procedure to set the connection is as follows:
          
1. Acquire connSoftPvcIndex
To set the connection, read connSoftPvcIndexNext and 
obtain an index of the Soft-PVPC/PVCC table.  The 
index must be managed by NMS. (The index is required 
to take an action to the connection.)
          
2. Set createAndWait
Set connSoftPvcRowStatus to CreateAndWait, using the 
obtained connSoftPvcIndex as index.  If the agent 
will set the parameter for the Soft-PVPC/PVCC 
setting to the default value and make 
connSoftRowStatus to notReady.
          
However, the same manager cannot create another row 
while creating a row (the status of the row is notRedy 
or notInService).
          
3. Get the default value
Get the default value of the object which serves as 
parameter for the connection setting. (The agent 
shall return -1 if it does not have a default value.)
          
Default values are as follows:
          
	connSoftPvcTopology		bi-directional-VCC(2)
	connSoftPvcTrafficType		traffic-UBR(5)
	connSoftPvcEndpointType		calling(1)
	connSoftPvcRetry		2
	connSoftPvcSrcAtmAddressFormat	nsap(2)
	connSoftPvcSrcAtmAddressLength	None
	connSoftPvcSrcAtmAddress	0 length string
	connSoftPvcSrcIfIndex		None
	connSoftPvcSrcVPI		None
	connSoftPvcSrcVCI		None
	connSoftPvcDstAtmAddressFormat	nsap(2)
	connSoftPvcDstAtmAddressLength	None
	connSoftPvcDstAtmAddress	0 length string
	connSoftPvcDstIfIndex		None
	connSoftPvcDstVPI		None
	connSoftPvcDstVCI		None
	connSoftPvcSrcFifoIndex		0
	connSoftPvcDstFifoIndex		0
	connSoftPvcNodeKind		model5(1)
	connSoftPvcSrcParam1		off(1)
	connSoftPvcDstParam1		off(1)
	connSoftPvcSrcParam2		0 length string
	connSoftPvcDstParam2		0 length string
	connSoftPvcSrcParam3		-1
	connSoftPvcDstParam3		-1
	connSoftPvcSrcParam4		-1
	connSoftPvcDstParam4		-1
	connSoftPvcSrcParam5		-1
	connSoftPvcDstParam5		-1
	connSoftPvcSrcParam6		off(2)
	connSoftPvcDstParam6		off(2)
	connSoftPvcSrcParam7		None (not installed)
	connSoftPvcDstParam7		None (not installed)
          
4. Set parameter
If a parameter does not have a default value, or the 
default value should not be used, set the parameter to 
a value.
If all parameters are set, the agent shall make 
connSoftPvcRowStatus to notInService.
          
5. Set active
By doing so, the agent checks parameters, resources and 
establishes the connection.
          
6. Get connSoftPvcRowStatus
If connSoftPvcRowStatus is active, the connection 
setting completed successfully, if notInService,the 
connection setting failed.  For the cause, refer to 
connSoftPvcCause.
(Note) When the connection setting has failed, if the 
connection is not released, the row will remain.
          
7. Get connSoftPvcRestRetry
Remaining counts of retry are contained.  If it is 
positive value, the retry is in progress.  If 
connSoftPvcRestRetry is 0, the retry completed.  The 
result of the connection setting should be seen, when 
this object is 0.
-1 means that infinite retry is in progress.
          
***Special pattern***
(1) If connSoftPvcTopology is bi-directional-VPC, set 
connSoftPvcSrcVCI, connSoftPvcDstVCI to 0.
          
The procedure to release the connection is as follows:
          
1. Set 'destroy'
Set connSoftPvcRowStatus to 'destroy', using 
connSoftPvcIndex of the connection to be deleted as 
index.
The agent will delete the connection, referring to 
it.
(Note) 'destroy' can also be set during the bypass 
processing.
          
2. Get the result
If the connection is deleted, 'get' of 
connSoftPvcTable of the designated index becomes 
NoSuchName.
          
The bypass processing of connection
          
1. Set notInService
When the agent executes the bypass processing of 
connection, set connSoftPvcRowStatus to 
notInService, and then establish the connection.
          
2. Get connSoftPvcRowStatus
If connSoftPvcRowStatus is 'active', the bypass 
connection setting has completed successfully.
If connSoftPvcRowStatus remains 'notInService', 
the connection setting has failed.
          
Others
          
1. The cut and recovery processing of connection is 
performed, following the delete and set procedures 
of the concerned connection.
Each procedure is as stated before.

Context

MIB
NEC-MIB
OID
.1.3.6.1.4.1.119.2.3.14.9.4.5
Type
table
Status
mandatory
Parent
conn
Children
1

Use a bulk walk to inspect objects and instances beneath this OID.

Walk the subtree
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'NEC-MIB' -M '/opt/observium/mibs/nec:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'NEC-MIB::connSoftPvcTable'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'NEC-MIB' -M '/opt/observium/mibs/nec:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'NEC-MIB::connSoftPvcTable'

Syntax

No syntax metadata recorded.

Values & Constraints