fxoPreDialDelay
MX-POTS-MIB ·
.0.1800.1.20000.100
Object
scalar
r/w
Unsigned32
FXO Pre Dial Delay
The delay between the time the line is successfully seized, or
dial tone detected, and the moment the destination phone
number is dialed.
A value of '0' indicates to use a value that is specific to
the country specification as set in the TelIf.CountrySelection
parameter.
This value is expressed in milliseconds (ms).
Context
- MIB
- MX-POTS-MIB
- OID
.0.1800.1.20000.100- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- fxoGroup
- Siblings
- 7
Syntax
Unsigned32
Values & Constraints
Object Constraints
range: 0-10000
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| fxoLinkStateVerificationGroup | node | - | .0.1800.1.20000.10100 |
| fxoForceEndOfCallGroup | node | - | .0.1800.1.20000.10200 |
| fxoDialToneDetectionMode FXO Dial Tone Detection Configuration
When dial tone detection is enabled, the unit waits for a dial
tone on the FXO line before initiating the dialling sequence.
If no… | scalar | Enumeration | .0.1800.1.20000.200 |
| fxoDialToneDetectionTimeout FXO Dial Tone Detection Timeout
Indicates how long the unit waits for a dial tone before
considering the line is busy with an incoming FXO call.
This value i… | scalar | Unsigned32 | .0.1800.1.20000.300 |
| fxoAnsweringDelayTable FXO Answering Delay
This table holds the answering delay configuration. Each row
in this table configures the answering delay of a line. | table | - | .0.1800.1.20000.5000 |
| fxoIncomingCallBehaviorTable FXO Incoming Call Behavior Table
Table that defines how each line behaves when there is an
incoming call. | table | - | .0.1800.1.20000.5100 |
| fxoCustomBasicParametersTable FXO Custom Basic Parameters
This table allows to override the default country basic
parameters for the FXO lines. This table is effective only if
the OverrideDefaultCou… | table | - | .0.1800.1.20000.5200 |