fxoCustomBasicParametersImpedance

MX-POTS-MIB · .0.1800.1.20000.5200.1.300

Object

column r/w Enumeration
Impedance
              
AC Impedance for the FXO line.
              
Not all values are supported on all hardware.
              
Impedance values are:
              
  * I600: 600 ohms.
  * I600LongLoop: 350 ohms + (1000 ohms || 210 nF).
  * I900: 900 ohms.
  * Others: Refer to the FXO properties section of the
    Country Specifications document.
              
For more details, refer to the Country Specifications
document published on the Media5 documentation portal.

Context

MIB
MX-POTS-MIB
OID
.0.1800.1.20000.5200.1.300
Type
column
Access
readwrite
Status
current
Parent
fxoCustomBasicParametersEntry

Syntax

Enumeration

Values & Constraints

Enumerated Values
100i600
200i600LongLoop
300i900
400australia
500austria
600belgium
700brazil
800china
900czechRepublic
1000denmark
1100finland
1200france
1300germany
1400greece
1500italy
1600japan
1700netherlands
1800newZealand
1900norway
2000russia
2100slovakia
2200spain
2300sweden
2400uK