defaultCodecG723MinPTime
MX-MIPT-MIB ·
.0.1600.1.100.400.400
Object
scalar
r/w
Unsigned32
Default G.723.1 Minimum Packetization Period Configuration
Lower boundary for the packetization period of the given
codec.
G.723.1 -> (30 ms|60 ms)
For reception, the range is extended from 30 ms to 120 ms with
increments of 30 ms only if the stream is not encrypted
(SRTP).
If a specific value is set for the
EpSpecificCodecG723.MinPTime parameter and the
EpSpecificCodecG723.EnableConfig parameter is set to 'Enable',
then the specific value will override the current default
value.
Context
- MIB
- MX-MIPT-MIB
- OID
.0.1600.1.100.400.400- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- codecG723Group
Syntax
Unsigned32
Values & Constraints
Object Constraints
range: 30-30
range: 60-60