defaultCodecG711MulawMinPTime

MX-MIPT-MIB · .0.1600.1.100.300.100.500

Object

scalar r/w Unsigned32
Default G.711 Mu-Law Minimum Packetization Period
Configuration
          
Lower boundary for the packetization period of the given
codec.
          
PCMU -> (10 ms..30 ms)
          
This value is expressed in ms, with increments of 10 ms.
          
For reception, the range is extended from 10 ms to 100 ms with
increments of 1 ms only if the stream is not encrypted (SRTP).
          
If a specific value is set for the
EpSpecificCodecG711Mulaw.MinPTime parameter and the
EpSpecificCodecG711Mulaw.EnableConfig parameter is set to
'Enable', then the specific value will override the current
default value.

Context

MIB
MX-MIPT-MIB
OID
.0.1600.1.100.300.100.500
Type
scalar
Access
readwrite
Status
current
Parent
codecG711MulawGroup

Scalars have one instance, identified by the .0 suffix.

Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'MX-MIPT-MIB' -M '/opt/observium/mibs/media5:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'MX-MIPT-MIB::defaultCodecG711MulawMinPTime.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'MX-MIPT-MIB' -M '/opt/observium/mibs/media5:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'MX-MIPT-MIB::defaultCodecG711MulawMinPTime'

Syntax

Unsigned32

Values & Constraints

Object Constraints
range: 10-30