statsInfoEBitErrors
MX-HARDWARE-MIB ·
.0.40000.1.2000.1000.100.1.1600
Object
column
Unsigned32
E-Bit Error
The E-Bit error count gives information about the outgoing
transmit PCM line if the E-bits are used by the remote end
for submultiframe error indication. Incrementing is only
possible in the multiframe synchronous state.
Due to signaling requirements, the E-bits of frame 13 and
frame 15 of the CRC multiframe can be used to indicate an
error in a received submultiframes:
* Submultiframe I status E-bit located in frame 13
* Submultiframe II status E-bit located in frame 15
* no CRC error: E = 1
* CRC error: E = 0
This value is only available in E1.