eamDigitTimerVariantsResetSpecific
MX-EAM-MIB ·
.0.1880.1.100.400.1.900
Object
column
r/w
Enumeration
Reset Specific
Resets specific settings of E&M Digit Timers parameters with
the default signaling type settings. This command is used to
retrieve the default configuration of the selected Signaling
Type set in the SignalingType parameter.
Context
- MIB
- MX-EAM-MIB
- OID
.0.1880.1.100.400.1.900- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- eamDigitTimerVariantsEntry
- Table
- eamDigitTimerVariantsTable
- Siblings
- 4
Syntax
Enumeration
Values & Constraints
Enumerated Values
0 | noOp |
10 | resetSpecific |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| eamDigitTimerVariantsInterfaceName Interface Name
Identifies the interface. | column | OctetString | .0.1880.1.100.400.1.100 |
| eamDigitTimerVariantsOverrideDefault Override Default
Overrides the default settings of E&M Signaling parameters
for the SignalingType and InterfaceName.
* Disable: The interface uses … | column | MX-TCMxEnableState | .0.1880.1.100.400.1.200 |
| eamDigitTimerVariantsKPOnTimeout Duration of the MF R1 KP signal
The time during which the MF R1 KP tone is on.
This value is expressed in milliseconds (ms). | column | Integer32 | .0.1880.1.100.400.1.300 |
| eamDigitTimerVariantsKPOffTimeout Duration of the off portion of the MF R1 KP signal
The duration of the pause after the MF R1 KP tone.
This value is expressed in milliseconds (ms). | column | Integer32 | .0.1880.1.100.400.1.400 |