genEquipUnitAlarmOutputAdmin

MWRM-UNIT-MIB · .1.3.6.1.4.1.2281.10.1.4.2.1.1.2

Object

column r/w Enumeration
The Admin state of the External output alarm. When 'Enabled', the functionality will be:
(i) If no alarms are raised, the N.O. (normally open) contact will be opened,
    while the N.C. (normally closed) contact will be connected to the COM contact.
(ii) When an alarm is raised, or the system power is OFF,
the N.O will be connected to the COM contact, while the N.C. contact will remain opened.
When 'Test' option is selected, the dry contacts behave as an alarm is raised in the system,
as described in case (ii) above.

Context

MIB
MWRM-UNIT-MIB
OID
.1.3.6.1.4.1.2281.10.1.4.2.1.1.2
Type
column
Access
readwrite
Status
current
Parent
genEquipUnitAlarmOutputEntry
Table
genEquipUnitAlarmOutputTable
Siblings
3

Syntax

Enumeration

Values & Constraints

Enumerated Values
0disable
1enable
2test

Related Objects

Sibling Objects