genEquipProtectionRevertiveMaxNumOfTries
MWRM-UNIT-MIB ·
.1.3.6.1.4.1.2281.10.1.6.15
Object
scalar
r/w
Integer32
Maximal number of revertive protection tries. Used to prevent instability. Revertive protection will give up trying to switch to the primary standby IDU path after the maximal number of tries. Setting Zero value will enable revertive protection switch only if the last protection switch was due to a local equipment failure.
Context
- MIB
- MWRM-UNIT-MIB
- OID
.1.3.6.1.4.1.2281.10.1.6.15- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- genEquipProtection
- Siblings
- 16
Syntax
Integer32
Values & Constraints
Object Constraints
range: 0-10
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| genEquipProtectionAdmin The Admin mode of the protection.
In case of protection2Plus2Hsb this parameter should be configured in
the main and extension slots. | scalar | Enumeration | .1.3.6.1.4.1.2281.10.1.6.1 |
| genEquipProtectionCopyToMateStatus This parameter represents the status of the copy-to-mate command when protection is enabled.
- ready(0)
- inProgress(1),
- success(2),
- failure(3) | scalar | ProgressStatus | .1.3.6.1.4.1.2281.10.1.6.10 |
| genEquipProtectionMultiUnitLAGAdmin This parameter enables the Multi Unit LAG feature.
It can be activated only in Single Pipe configuration and only when protection is active (either 1+1 or 2+2). | scalar | EnableDisable | .1.3.6.1.4.1.2281.10.1.6.11 |
| genEquipProtectionRevertiveAdmin Enable/Disable revertive protection mode. In revertive protection mode one IDU will be defined as a Primary and the other will be Secondary.
Revertive protection will always tend … | scalar | EnableDisable | .1.3.6.1.4.1.2281.10.1.6.12 |
| genEquipProtectionRevertivePrimaryIDU Decides whether upper or lower IDU will be primary. When placed in a shelf, the upper will be the upper slot in the shelf.
When working in stand-alone mode, the IDU with the highe… | scalar | Enumeration | .1.3.6.1.4.1.2281.10.1.6.13 |
| genEquipProtectionRevertiveMinTimer Minimal revertive protection timer period. | scalar | Integer32 | .1.3.6.1.4.1.2281.10.1.6.14 |
| genEquipProtectionRevertiveTimerMultiplier A factor that increases the revertive timer period after each try. Setting 1 value will leave the timer period constantly at its minimal value. | scalar | Integer32 | .1.3.6.1.4.1.2281.10.1.6.16 |
| genEquipProtectionAspRevertive n Smart Pipe HSB mode , this parameter causes the Ethernet line port to be muted upon a complete failure of
the radio signal (in both active and standby units) | scalar | EnableDisable | .1.3.6.1.4.1.2281.10.1.6.17 |
| genEquipProtectionMode In protection mode, the card can be either active or standby | scalar | Enumeration | .1.3.6.1.4.1.2281.10.1.6.2 |
| genEquipProtectionMateIPAddr Same parameter as genEquipNetworkMateIp.
In case of 1+1 protection it is the protected card (Mate) IP address.
In case of 2+2 protection it is the IP address of the protected unit. | scalar | SNMPv2-SMIIpAddress | .1.3.6.1.4.1.2281.10.1.6.3 |
| genEquipProtectionMateMACAddr In case of 1+1 protection it is protected card (Mate) MAC address
In case of 2+2 protection it is the IP address of the protected unit. | scalar | SNMPv2-TCMacAddress | .1.3.6.1.4.1.2281.10.1.6.4 |
| genEquipProtectionRadioExcessiveBERSwitch The Admin state of an Excessive BER threshold. When enabled, crossing the Excessive BER threshold will cause
a protection switch. | scalar | EnableDisable | .1.3.6.1.4.1.2281.10.1.6.5 |
| genEquipProtectionLockout This parameter provides the ability to lock the mode of each card in the protection,
meaning to force the fact that protection switch will not occur. | scalar | OffOn | .1.3.6.1.4.1.2281.10.1.6.6 |
| genEquipProtectionForceSwitch This parameter is a command that forces a protection switch regardless of the state of the standby card. | scalar | OffOn | .1.3.6.1.4.1.2281.10.1.6.7 |
| genEquipProtectionManualSwitch This parameter is a command that performs manaual protection switch. | scalar | OffOn | .1.3.6.1.4.1.2281.10.1.6.8 |
| genEquipProtectionCopyToMateComand Setting this parameter to On will copy configured parameters from the active to the standby unit. | scalar | OffOn | .1.3.6.1.4.1.2281.10.1.6.9 |