osamLaserBiasCurrent
LUXN-MIB ·
.1.3.6.1.4.1.4253.1.15.6.1.17
Object
column mandatory
r/w
Integer32
Constant current in mA to be used by the module when the operation mode is set to currentControlled. This value can't be set if operation mode is set to gainControlled. Applicable only to OSAM module
Net-SNMP examples
How SNMP and these commands workWalk the column to discover its indexed instances, or supply every index to read one instance.
Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'LUXN-MIB' -M '/opt/observium/mibs/zhone:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'LUXN-MIB::osamLaserBiasCurrent'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'LUXN-MIB' -M '/opt/observium/mibs/zhone:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'LUXN-MIB::osamLaserBiasCurrent.<osamCardLocation>.<osamCardShelf>.<osamCardSlot>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'LUXN-MIB' -M '/opt/observium/mibs/zhone:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'LUXN-MIB::osamLaserBiasCurrent'
Syntax
Integer32
Values & Constraints
Object Constraints
range: 40-200