wdmCtrlGroupChannelStartupCommand
LUM-WDM-MIB ·
.1.3.6.1.4.1.8708.2.4.2.9.1.1.23
Object
column
LUM-TCCommandString
Initiates a safe startup sequence for all the
channels of selected group. If the administrative
status of the channel is 'down' or the channel is
not detected by the monitor unit, the system attempts
to detect the channel as follows:
1) The attenuation is set to its maximum value.
2) The attenuation is decreased until the channel is
detected by the monitor.
When the channel is detected, regulation of the
channel is started, ignoring the regulation range.
If the channel cannot be detected, channelStatus is
set to notFound. If regulation fails, channelStatus
is set to 'error' and an alarm is raised.
When the startup sequence is finished, the
administrative status of the channel is set to 'up'.
If a regulation is ongoing when the startup
procedure is initiated, the channel is put on a
waiting queue until the ongoing regulation is
finished. The startup queue has a limited length. If
the queue is filled up with waiting channels,
further startup commands will be blocked until all
the queued channels have been started.
Context
- MIB
- LUM-WDM-MIB
- OID
.1.3.6.1.4.1.8708.2.4.2.9.1.1.23- Type
- column
- Access
- readonly
- Status
- current
- Parent
- wdmCtrlGroupEntry
Syntax
LUM-TCCommandString
Values & Constraints
No enumerated values or constraints recorded.