pmIfRxSES

LUM-PM-MIB · .1.3.6.1.4.1.8708.2.15.2.6.1.1.40

Object

column LUM-TCFaultStatus
Severely errored seconds (SES) Rx 15 min
threshold exceeded.
              
A: The number of severely errored seconds during
a period exceeds the associated threshold.
              
D: At the start of a new 15 minute period the
associated SES counter is reset to zero, by
definition. At the same time the fault status
is cleared. The corresponding active alarm in
the alarm list, if any, is not cleared for
another 20 seconds to avoid unneccesary toggling
in the alarm list and log.

Context

MIB
LUM-PM-MIB
OID
.1.3.6.1.4.1.8708.2.15.2.6.1.1.40
Type
column
Access
readonly
Status
current
Parent
pmIfEntry
Table
pmIfTable
Siblings
71

Syntax

LUM-TCFaultStatus
Source
LUM-TCFaultStatus
Base type
Enumeration

Values & Constraints

Type Values
1ok
2alarm

Related Objects

Sibling Objects