ifOtnMonPmCRxAlarmIndicationSignal

LUM-IFOTNMON-MIB · .1.3.6.1.4.1.8708.2.55.2.4.1.1.18

Object

Rx Alarm indication signal (AIS),
              
Monitored overhead: ODUCn-PM-AIS
              
Direction: Received from the associated physical interface
and, unless the ODUC is terminated, the AIS is sent  towards
the board-internal G.805 Matrix.
              
Reference: 16.5.1 G.709, 15.8.2.2.5 G.709, 6.2.6.3.2 G.798
              
Values:
alarm: The ODUCn-PM-AIS overhead is declared as active according to
      the G.798 processing rules
              
ok: The ODUCn-PM-AIS overhead is declared as inactive according to
   the G.798 processing rules

Context

MIB
LUM-IFOTNMON-MIB
OID
.1.3.6.1.4.1.8708.2.55.2.4.1.1.18
Type
column
Access
readonly
Status
current
Parent
ifOtnMonPmEntry
Groups
1

Walk the column to discover its indexed instances, or supply every index to read one instance.

Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'LUM-IFOTNMON-MIB' -M '/opt/observium/mibs/infinera:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'LUM-IFOTNMON-MIB::ifOtnMonPmCRxAlarmIndicationSignal'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'LUM-IFOTNMON-MIB' -M '/opt/observium/mibs/infinera:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'LUM-IFOTNMON-MIB::ifOtnMonPmCRxAlarmIndicationSignal.<ifOtnMonPmIndex>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'LUM-IFOTNMON-MIB' -M '/opt/observium/mibs/infinera:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'LUM-IFOTNMON-MIB::ifOtnMonPmCRxAlarmIndicationSignal'

Syntax

Source
LUM-TCFaultStatusWithNA
Base type
Enumeration
Type Description
A value indicating the current state
of a potential fault condition leading to
an alarm for an object.
          
ok - indicates that no fault condition is present
and no alarm is active or the alarm has been cleared.
          
alarm - indicates that a fault condition is present
and an alarm is active.
          
notApplicable - used to tell that attribute
is not used in current configuration.
          
Note: The list of FaultStatus objects forms the list of all
potential alarms for the system.

Values & Constraints

Type Values
1ok
2alarm
2147483647notApplicable

Conformance