ifOpticalChannelLaserNotTuned

LUM-IFOPTICAL-MIB · .1.3.6.1.4.1.8708.2.48.2.3.1.1.12

Object

Laser not tuned.
              
The tunable laser is not tuned to set frequency yet.
This alarm can be cleared by setting the attribute
LaserForcedOn to enabled. Note that this can disturb
traffic. See the help for LaserForcedOn in optical
transsection for more information.
              
alarm: Tunable laser is not tuned to set frequency.
              
ok: Tunable laser is tuned to set frequency.

Context

MIB
LUM-IFOPTICAL-MIB
OID
.1.3.6.1.4.1.8708.2.48.2.3.1.1.12
Type
column
Access
readonly
Status
current
Parent
ifOpticalChannelEntry
Groups
7

Walk the column to discover its indexed instances, or supply every index to read one instance.

Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'LUM-IFOPTICAL-MIB' -M '/opt/observium/mibs/infinera:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'LUM-IFOPTICAL-MIB::ifOpticalChannelLaserNotTuned'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'LUM-IFOPTICAL-MIB' -M '/opt/observium/mibs/infinera:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'LUM-IFOPTICAL-MIB::ifOpticalChannelLaserNotTuned.<ifOpticalChannelIndex>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'LUM-IFOPTICAL-MIB' -M '/opt/observium/mibs/infinera:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'LUM-IFOPTICAL-MIB::ifOpticalChannelLaserNotTuned'

Syntax

Source
LUM-TCFaultStatusWithNA
Base type
Enumeration
Type Description
A value indicating the current state
of a potential fault condition leading to
an alarm for an object.
          
ok - indicates that no fault condition is present
and no alarm is active or the alarm has been cleared.
          
alarm - indicates that a fault condition is present
and an alarm is active.
          
notApplicable - used to tell that attribute
is not used in current configuration.
          
Note: The list of FaultStatus objects forms the list of all
potential alarms for the system.

Values & Constraints

Type Values
1ok
2alarm
2147483647notApplicable