clientIfTrxAutoTuneFailure

LUM-CLIENT-MIB · .1.3.6.1.4.1.8708.2.27.2.2.1.1.160

Object

The auto-tune process of an Auto-Lambda transceiver failed to establish the correct DWDM channel.
This alarm does not indicate a loss of signal. The optical signal is received but the tranceiver
failed to handshake the selection of DWDM channel with its peer tranceiver.
This alarm indicates that the wrong type of transceiver is inserted at either end.
              
alarm: The transceiver is unable to automatically establish the correct DWDM channel.
              
ok: The transceiver is able to automatically establish the correct DWDM channel.

Context

MIB
LUM-CLIENT-MIB
OID
.1.3.6.1.4.1.8708.2.27.2.2.1.1.160
Type
column
Access
readonly
Status
current
Parent
clientIfEntry
Groups
5

Walk the column to discover its indexed instances, or supply every index to read one instance.

Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'LUM-CLIENT-MIB' -M '/opt/observium/mibs/infinera:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'LUM-CLIENT-MIB::clientIfTrxAutoTuneFailure'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'LUM-CLIENT-MIB' -M '/opt/observium/mibs/infinera:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'LUM-CLIENT-MIB::clientIfTrxAutoTuneFailure.<clientIfIndex>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'LUM-CLIENT-MIB' -M '/opt/observium/mibs/infinera:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'LUM-CLIENT-MIB::clientIfTrxAutoTuneFailure'

Syntax

Source
LUM-TCFaultStatus
Base type
Enumeration
Type Description
A value indicating the current state
of a potential fault condition leading to
an alarm for an object.
          
ok - indicates that no fault condition is present
and no alarm is active or the alarm has been cleared.
          
alarm - indicates that a fault condition is present
and an alarm is active.
          
Note: The list of FaultStatus objects forms the list of all
potential alarms for the system.

Values & Constraints

Type Values
1ok
2alarm