mcEndptStatus
LIGHTSTREAM-MIB ·
.1.3.6.1.4.1.711.2.1.8.7.1.1.99
Object
column
mandatory
r/w
Enumeration
This variable indicates the Status of this Virtual
Circuit. It may be enabled or disabled.
In order to modify a Virtual Circuit, the new
desired variables should be modified and then
this variable should be set (or set again) to
enabled. At that time desired variables will
become the operational (or in-use) variables.
To remove a PVC, set its status to delete.
By default, if not configured when creating the
entry, the status is disabled.
An existing instance of this object cannot be set to
createRequest(4). This object may only be set to
createRequest(4) when this instance is created. When
this object is created, the agent may wish to create
supplemental object instances to complete a conceptual
row in this table. Immediately after completing the
create operation, the agent must set this object to
underCreation(5).
Entries shall exist in the underCreation(5) state until
the management station is finished configuring the
entry and sets this object to active(1), inactive(2),
or aborts, setting this object to delete(4). If the
agent determines that an entry has been in the
underCreation(5) state for an abnormally long time,
it may decide that the management station has
become unavailable. If the agent makes this decision,
it may set this object to delete(3) to reclaim the
entry. A prudent agent will understand that the
management station may need to wait for human input
and will allow for that possibility in its
determination of this abnormally long period.
Context
- MIB
- LIGHTSTREAM-MIB
- OID
.1.3.6.1.4.1.711.2.1.8.7.1.1.99- Type
- column
- Access
- readwrite
- Status
- mandatory
- Parent
- mcEndptEntry
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | enabled |
2 | disabled |
3 | delete |
4 | createRequest |
5 | underCreation |