juniV35IfClockRate

Juniper-V35-MIB · .1.3.6.1.4.1.4874.2.2.59.1.2.1.4

Object

column r/w hertz Unsigned32
The clock rate setting in hertz for this X.21/V.35 interface.  Only the
following values are valid: 1200, 2400, 4800, 9600, 19200, 38400, 56000,
64000, 128000, 1024000, 1536000, 2048000, 3072000, 4096000, 4915200,
6144000, and 8192000.  If a value other than one of the predefined
values is set, then the closest matching value is used.
              
The clock rate parameter is only meaningful when the interface is in DCE
mode.  When the interface is in DTE mode, the value is simply ignored.

Context

MIB
Juniper-V35-MIB
OID
.1.3.6.1.4.1.4874.2.2.59.1.2.1.4
Type
column
Access
readwrite
Status
current
Units
hertz
Parent
juniV35IfEntry

Syntax

hertz Unsigned32

Values & Constraints