juniSystemMaxModulesPerSlot
Juniper-System-MIB ·
.1.3.6.1.4.1.4874.2.2.2.1.3.2
Object
scalar Integer32
The maximum number of modules and sub-modules (different levels) that
can be associated with a slot number in the system. This value is
constant for a particular hardware platform family. The number of
levels is 2 for a first generation E-series (ERX) platform and is 4 for
a second generation E-series platform.
For the first generation E-series (ERX) platform family:
level 1 - SRP or line card module
level 2 - I/O adapter module
For the second generation E-series platform family:
level 1 - Forwarding module or SRP sub-module
level 2 - Switch fabric slice (SFS) sub-module or module
level 3 - Bay 0 I/O adapter
level 4 - Bay 1 I/O adapter
Context
- MIB
- Juniper-System-MIB
- OID
.1.3.6.1.4.1.4874.2.2.2.1.3.2- Type
- scalar
- Access
- readonly
- Status
- current
- Parent
- juniSystemModule
- Groups
- 3
Net-SNMP examples
How SNMP and these commands workScalars have one instance, identified by the .0 suffix.
Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'Juniper-System-MIB' -M '/opt/observium/mibs/junose:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'Juniper-System-MIB::juniSystemMaxModulesPerSlot.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'Juniper-System-MIB' -M '/opt/observium/mibs/junose:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'Juniper-System-MIB::juniSystemMaxModulesPerSlot'
Syntax
Integer32
Values & Constraints
Object Constraints
range: 1-255