juniHdlcIfRowStatus
Juniper-HDLC-MIB ·
.1.3.6.1.4.1.4874.2.2.9.1.2.1.2
Object
Controls creation/deletion of entries in this table according to the
RowStatus textual convention, constrained to support the following
values only:
createAndGo
destroy
To create an entry in this table, the following entry objects MUST be
explicitly configured:
juniHdlcIfRowStatus
juniHdlcIfLowerIfIndex
In addition, when creating an entry the following conditions must hold:
A value for juniHdlcIfIndex must have been determined previously, by
reading juniHdlcNextIfIndex.
The interface identified by juniHdlcIfLowerIfIndex must exist.
A corresponding entry in ifTable/ifXTable/juniIfTable is created/
destroyed as a result of creating/destroying an entry in this table.
Context
- MIB
- Juniper-HDLC-MIB
- OID
.1.3.6.1.4.1.4874.2.2.9.1.2.1.2- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- juniHdlcIfEntry
- Table
- juniHdlcIfTable
- Siblings
- 10
Values & Constraints
Type Values
1 | active |
2 | notInService |
3 | notReady |
4 | createAndGo |
5 | createAndWait |
6 | destroy |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| juniHdlcIfIndex The ifIndex of the HDLC interface. When creating entries in this
table, suitable values for this object are determined by reading
juniHdlcNextIfIndex. | column | IF-MIBInterfaceIndex | .1.3.6.1.4.1.4874.2.2.9.1.2.1.1 |
| juniHdlcIfForceDteAck The force DTE acknowledge setting. This object is only applicable to
HDLC interfaces directly over a high speed serial interface (HSSI).
This is set to force Cisco compatibility … | column | Enumeration | .1.3.6.1.4.1.4874.2.2.9.1.2.1.10 |
| juniHdlcIfIdleCharacter The HDLC idle character has two possible settings. The value can be
set to idleCharacterFlags which translates to 0x7E or it can be set to
idleCharacterMarks which translates to … | column | Enumeration | .1.3.6.1.4.1.4874.2.2.9.1.2.1.11 |
| juniHdlcIfLowerIfIndex The ifIndex of an interface over which this HDLC interface is to be
layered. A value of zero indicates no layering. An implementation may
choose to require that a nonzero value … | column | IF-MIBInterfaceIndexOrZero | .1.3.6.1.4.1.4874.2.2.9.1.2.1.3 |
| juniHdlcIfMtu The Maximum Transmission Unit (MTU) this interface is permitted to
transmit.
At creation, if a value for this object is not specified, a default will
be chosen that… | column | octets Integer32 | .1.3.6.1.4.1.4874.2.2.9.1.2.1.4 |
| juniHdlcIfMru The Maximum Receive Unit (MRU) this interface is permitted to receive.
At creation, if a value for this object is not specified, a default will
be chosen that is su… | column | octets Integer32 | .1.3.6.1.4.1.4874.2.2.9.1.2.1.5 |
| juniHdlcIfCrcSize Selects the CRC size: none, 16 bits, or 32 bits. | column | Enumeration | .1.3.6.1.4.1.4874.2.2.9.1.2.1.6 |
| juniHdlcIfDataPolarity Polarity of data transmitted on this HDLC interface. Inverted data is
used for certain line coding configurations to ensure sufficient one's
density for timing recovery by the re… | column | Enumeration | .1.3.6.1.4.1.4874.2.2.9.1.2.1.7 |
| juniHdlcIfClockMode The clock mode setting for this HDLC interface. This object is only
applicable to HDLC interfaces directly over a high speed serial
interface (HSSI).
At creation, … | column | Enumeration | .1.3.6.1.4.1.4874.2.2.9.1.2.1.8 |
| juniHdlcIfClockRate The clock rate setting for this HDLC interface. This object is only
applicable to HDLC interfaces directly over a high speed serial
interface (HSSI).
At creation, … | column | Enumeration | .1.3.6.1.4.1.4874.2.2.9.1.2.1.9 |