jnxPsuChassisPowerConsumed

JUNIPER-POWER-SUPPLY-UNIT-MIB · .1.3.6.1.4.1.2636.3.58.1.2.1.9

Object

scalar Integer32
Total power consumed by the entire system rounded to the nearest integer.
This is calculated using the PowerFactor, Current and Voltage values 
of each PSU that is online and connected to the System.

Context

MIB
JUNIPER-POWER-SUPPLY-UNIT-MIB
OID
.1.3.6.1.4.1.2636.3.58.1.2.1.9
Type
scalar
Access
readonly
Status
current
Parent
jnxPsuScalars

Scalars have one instance, identified by the .0 suffix.

Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'JUNIPER-POWER-SUPPLY-UNIT-MIB' -M '/opt/observium/mibs/juniper:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'JUNIPER-POWER-SUPPLY-UNIT-MIB::jnxPsuChassisPowerConsumed.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'JUNIPER-POWER-SUPPLY-UNIT-MIB' -M '/opt/observium/mibs/juniper:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'JUNIPER-POWER-SUPPLY-UNIT-MIB::jnxPsuChassisPowerConsumed'

Syntax

Source
SNMPv2-SMIInteger32
Base type
Integer32

Values & Constraints

Type Constraints
range: -2147483648..2147483647