JUNIPER-POWER-SUPPLY-UNIT-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
4
Rows
4
Columns
17

jnxPsuTable

table
.1.3.6.1.4.1.2636.3.58.1.2.2 · 1 row entry · 4 columns
Uses the juniper variant from /opt/observium/mibs/juniper.
Command help
Walk jnxPsuTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'JUNIPER-POWER-SUPPLY-UNIT-MIB' -M '/opt/observium/mibs/juniper:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'JUNIPER-POWER-SUPPLY-UNIT-MIB::jnxPsuTable'
A list of power entries for each PSU component.
jnxPsuEntry row .1.3.6.1.4.1.2636.3.58.1.2.2.1
Defines an entry in jnxPsuTable.
Column Syntax OID
Buffer that contains the average power used, in Watts
for each component.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2636.3.58.1.2.2.1.1
Buffer that contains the max power available, in Watts
for each component.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2636.3.58.1.2.2.1.2
Mode for each PSU component.
Enumeration
Enumerated Values:
1single
3three
.1.3.6.1.4.1.2636.3.58.1.2.2.1.3
The number of outlets (regardless of their current state)
present on this psu component, default is 0.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2636.3.58.1.2.2.1.4
.1.3.6.1.4.1.2636.3.58.1.2.3 · 1 row entry · 2 columns
Uses the juniper variant from /opt/observium/mibs/juniper.
Command help
Walk jnxPsuEnvironmentTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'JUNIPER-POWER-SUPPLY-UNIT-MIB' -M '/opt/observium/mibs/juniper:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'JUNIPER-POWER-SUPPLY-UNIT-MIB::jnxPsuEnvironmentTable'
A list of PSU Environment entries.
jnxPsuEnvironmentEntry row .1.3.6.1.4.1.2636.3.58.1.2.3.1
Defines an entry in jnxPsuEnvironmentTable.
Column Syntax OID
Temparature at each component in degrees Celsius rounded to
the nearest integer.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2636.3.58.1.2.3.1.1
Humidity at each component in percentage.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2636.3.58.1.2.3.1.2
.1.3.6.1.4.1.2636.3.58.1.2.4 · 1 row entry · 9 columns
Uses the juniper variant from /opt/observium/mibs/juniper.
Command help
Walk jnxPsuOutletTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'JUNIPER-POWER-SUPPLY-UNIT-MIB' -M '/opt/observium/mibs/juniper:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'JUNIPER-POWER-SUPPLY-UNIT-MIB::jnxPsuOutletTable'
Gives details of each Power outlet`s state,
capacity to supply power, and other details.
jnxPsuOutletEntry row .1.3.6.1.4.1.2636.3.58.1.2.4.1
A value contained within the OutletEntry
Column Syntax OID
Outlet name associated to the power supply unit for
each PSU Component.
OctetString
Constraints:
range: 0-15
.1.3.6.1.4.1.2636.3.58.1.2.4.1.1
Outlet description associated to the power supply unit for
each PSU Component.
OctetString
Constraints:
range: 0-63
.1.3.6.1.4.1.2636.3.58.1.2.4.1.2
Buffer that contains the average power used, in Watts for each component.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2636.3.58.1.2.4.1.3
Buffer that contains the maximum power available, in Watts for each component.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2636.3.58.1.2.4.1.4
PSU output current in milliamps rounded to the nearest
integer.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2636.3.58.1.2.4.1.5
The value of the operational status for the given outlet.
This can also be used to set the outlet state
Enumeration
Enumerated Values:
0off
1on
.1.3.6.1.4.1.2636.3.58.1.2.4.1.8
Output voltage in Volts rounded to the nearest integer.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2636.3.58.1.2.4.1.9
Power factor percentage of each PSU (2k/3k).

Algorithm for calculation of Power Factor is below.
For PowerOut values that fall in between 618.93W and 915.24W,
say 700W, the appropriate PF ranges from 0.91…
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2636.3.58.1.2.4.1.10
Power Consumed by each outlet units in Watts.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2636.3.58.1.2.4.1.11
.1.3.6.1.4.1.2636.3.58.1.2.5 · 1 row entry · 2 columns
Uses the juniper variant from /opt/observium/mibs/juniper.
Command help
Walk jnxPsuFpcPowerTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'JUNIPER-POWER-SUPPLY-UNIT-MIB' -M '/opt/observium/mibs/juniper:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'JUNIPER-POWER-SUPPLY-UNIT-MIB::jnxPsuFpcPowerTable'
A list of entries for each FPC(Flexible PIC Concentrator)
giving it's assigned priority and power being allocated. 
More information on FPCs can be found in JUNIPER-MIB.
jnxPsuFpcPowerEntry row .1.3.6.1.4.1.2636.3.58.1.2.5.1
A value contained within the FpcPowerEntry
Column Syntax OID
The Power budget priority assigned to the FPC.
Lower number means higher priority.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2636.3.58.1.2.5.1.1
The Power allocated to the FPC in Watts.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2636.3.58.1.2.5.1.2