jnxPPPoEIfLockoutMax
JNX-PPPOE-MIB ·
.1.3.6.1.4.1.2636.3.67.1.1.1.2.1.13
Object
column
Integer32
The upper bound, in seconds, of the time range used to specify
the duration of the lockout of the client from recognition for
the specified interface. This only takes effect if
jnxPPPoEIfAutoconfig is set for this interface.
The ability to lockout the client from recognition in the event
of an error in creating a PPP interface is enabled by default.
The initial lockout duration is jnxPPPoEIfLockoutMin and
increases exponentially for each failure that occurs for the client
interface within the greater of 15 minutes and this object's value.
The lockout duration for the client will not exceed jnxPPPoEIfLockoutMax.
If the time between creation errors for the PPP interface for this
interface is greater than the greater of 15 minutes and
jnxPPPoEIfLockoutMax, then the lockout duration reverts to
jnxPPPoEIfLockoutMin.
To disable the ability to lockout the client from recognition in the
event of an error in creating a PPP interface for the specified interface,
the value of this object and jnxPPPoEIfLockoutMin must be set to 0.
It is not recommended that this lockout feature be disabled except for
debugging purposes or when this interface supports more than one session.
Context
- MIB
- JNX-PPPOE-MIB
- OID
.1.3.6.1.4.1.2636.3.67.1.1.1.2.1.13- Type
- column
- Access
- readonly
- Status
- current
- Parent
- jnxPPPoEIfEntry
Syntax
Integer32
Values & Constraints
Object Constraints
range: 0-86400