ipeFsUpdateFileUpdateList

IPE-SYSTEM-MIB · .1.3.6.1.4.1.119.2.3.69.5.2.1.1.11

Object

Definition of update slot number.
              
Form of file list:
When downloading it to ODU/FPGA/MDPRM, the forwarding site slot
number is enumerated by a comma end.
              
Ex) 0,5,1,6,10...
  The slot number of relating MODEM and fpga must set the slot
number of
  Option Card to odu and mdprm according to inventory
information.
              
The slot number to which the current state can be set becomes the
following.
              
iPASO200             iPASO400,1000
0 : MainBoard     or SLOT0
1 : MODEM1        or SLOT1
2 : MODEM2        or SLOT2
3 : Option Card   or SLOT3
      :
33: ODU1
34: ODU2
35: ODU3
      :
              
*Pertinent details: ipeFsUpdateFileDetail

Context

MIB
IPE-SYSTEM-MIB
OID
.1.3.6.1.4.1.119.2.3.69.5.2.1.1.11
Type
column
Access
readwrite
Status
current
Parent
ipeFsFileInfoEntry

Walk the column to discover its indexed instances, or supply every index to read one instance.

Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'IPE-SYSTEM-MIB' -M '/opt/observium/mibs/nec:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'IPE-SYSTEM-MIB::ipeFsUpdateFileUpdateList'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'IPE-SYSTEM-MIB' -M '/opt/observium/mibs/nec:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'IPE-SYSTEM-MIB::ipeFsUpdateFileUpdateList.<ipeFsFileInfoIndex>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'IPE-SYSTEM-MIB' -M '/opt/observium/mibs/nec:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'IPE-SYSTEM-MIB::ipeFsUpdateFileUpdateList'

Syntax

Source
SNMPv2-TCDisplayString
Base type
OctetString
Display format
255a
Type Description
Represents textual information taken from the NVT ASCII
          
character set, as defined in pages 4, 10-11 of RFC 854.
          
To summarize RFC 854, the NVT ASCII repertoire specifies:
          
  - the use of character codes 0-127 (decimal)
          
  - the graphics characters (32-126) are interpreted as
    US ASCII
          
  - NUL, LF, CR, BEL, BS, HT, VT and FF have the special
    meanings specified in RFC 854
          
  - the other 25 codes have no standard interpretation
          
  - the sequence 'CR LF' means newline
          
  - the sequence 'CR NUL' means carriage-return
          
  - an 'LF' not preceded by a 'CR' means moving to the
    same column on the next line.
          
  - the sequence 'CR x' for any x other than LF or NUL is
    illegal.  (Note that this also means that a string may
    end with either 'CR LF' or 'CR NUL', but not with CR.)
          
Any object defined using this syntax may not exceed 255
characters in length.

Values & Constraints

Type Constraints
range: 0..255