ipeFsUpdateFileUpdateList
IPE-SYSTEM-MIB ·
.1.3.6.1.4.1.119.2.3.69.5.2.1.1.11
Object
Definition of update slot number.
Form of file list:
When downloading it to ODU/FPGA/MDPRM, the forwarding site slot
number is enumerated by a comma end.
Ex) 0,5,1,6,10...
The slot number of relating MODEM and fpga must set the slot
number of
Option Card to odu and mdprm according to inventory
information.
The slot number to which the current state can be set becomes the
following.
iPASO200 iPASO400,1000
0 : MainBoard or SLOT0
1 : MODEM1 or SLOT1
2 : MODEM2 or SLOT2
3 : Option Card or SLOT3
:
33: ODU1
34: ODU2
35: ODU3
:
*Pertinent details: ipeFsUpdateFileDetail
Context
- MIB
- IPE-SYSTEM-MIB
- OID
.1.3.6.1.4.1.119.2.3.69.5.2.1.1.11- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- ipeFsFileInfoEntry
Net-SNMP examples
How SNMP and these commands workWalk the column to discover its indexed instances, or supply every index to read one instance.
Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'IPE-SYSTEM-MIB' -M '/opt/observium/mibs/nec:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'IPE-SYSTEM-MIB::ipeFsUpdateFileUpdateList'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'IPE-SYSTEM-MIB' -M '/opt/observium/mibs/nec:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'IPE-SYSTEM-MIB::ipeFsUpdateFileUpdateList.<ipeFsFileInfoIndex>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'IPE-SYSTEM-MIB' -M '/opt/observium/mibs/nec:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'IPE-SYSTEM-MIB::ipeFsUpdateFileUpdateList'
Syntax
- Source
- SNMPv2-TCDisplayString
- Base type
OctetString- Display format
255a
Type Description
Represents textual information taken from the NVT ASCII
character set, as defined in pages 4, 10-11 of RFC 854.
To summarize RFC 854, the NVT ASCII repertoire specifies:
- the use of character codes 0-127 (decimal)
- the graphics characters (32-126) are interpreted as
US ASCII
- NUL, LF, CR, BEL, BS, HT, VT and FF have the special
meanings specified in RFC 854
- the other 25 codes have no standard interpretation
- the sequence 'CR LF' means newline
- the sequence 'CR NUL' means carriage-return
- an 'LF' not preceded by a 'CR' means moving to the
same column on the next line.
- the sequence 'CR x' for any x other than LF or NUL is
illegal. (Note that this also means that a string may
end with either 'CR LF' or 'CR NUL', but not with CR.)
Any object defined using this syntax may not exceed 255
characters in length.
Values & Constraints
Type Constraints
range: 0..255