otsPtpPmOtsLpwr4Min
INFINERA-PM-OTSPTP-MIB ·
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.31
Object
column
INFINERA-TC-MIBFloatHundredths
OTS Laser Pump Power for Pump 4, minimum (dBm)
Context
- MIB
- INFINERA-PM-OTSPTP-MIB
- OID
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.31- Type
- column
- Access
- readonly
- Status
- current
- Parent
- otsPtpPmEntry
- Table
- otsPtpPmTable
- Siblings
- 41
Syntax
INFINERA-TC-MIBFloatHundredths
- Source
- INFINERA-TC-MIBFloatHundredths
- Base type
Integer32
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| otsPtpPmTimestamp End Time stamp for this interval. If this time is later than the current time,
then the data for this bucket is currently being collected. | column | Integer32 | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.1 |
| otsPtpPmOtsLbc1Min OTS Laser Bias Current for Pump 1, minimum (mA) | column | INFINERA-TC-MIBFloatHundredths | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.10 |
| otsPtpPmOtsLbc1Max OTS Laser Bias Current for Pump 1, maximum (mA) | column | INFINERA-TC-MIBFloatHundredths | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.11 |
| otsPtpPmOtsLbc1Ave OTS Laser Bias Current for Pump 1, average (mA) | column | INFINERA-TC-MIBFloatHundredths | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.12 |
| otsPtpPmOtsLbc2Min OTS Laser Bias Current for Pump 2, minimum (mA) | column | INFINERA-TC-MIBFloatHundredths | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.13 |
| otsPtpPmOtsLbc2Max OTS Laser Bias Current for Pump 2, maximum (mA) | column | INFINERA-TC-MIBFloatHundredths | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.14 |
| otsPtpPmOtsLbc2Ave OTS Laser Bias Current for Pump 2, average (mA) | column | INFINERA-TC-MIBFloatHundredths | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.15 |
| otsPtpPmOtsLbc3Min OTS Laser Bias Current for Pump 3, minimum (mA) | column | INFINERA-TC-MIBFloatHundredths | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.16 |
| otsPtpPmOtsLbc3Max OTS Laser Bias Current for Pump 3, maximum (mA) | column | INFINERA-TC-MIBFloatHundredths | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.17 |
| otsPtpPmOtsLbc3Ave OTS Laser Bias Current for Pump 3, average (mA) | column | INFINERA-TC-MIBFloatHundredths | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.18 |
| otsPtpPmOtsLbc4Min OTS Laser Bias Current for Pump 4, average (mA) | column | INFINERA-TC-MIBFloatHundredths | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.19 |
| otsPtpPmSampleDuration The duration of this sample. | column | Enumeration | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.2 |
| otsPtpPmOtsLbc4Max OTS Laser Bias Current for Pump 4, maximum (mA) | column | INFINERA-TC-MIBFloatHundredths | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.20 |
| otsPtpPmOtsLbc4Ave OTS Laser Bias Current for Pump 4, average (mA) | column | INFINERA-TC-MIBFloatHundredths | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.21 |
| otsPtpPmOtsLpwr1Min OTS Laser Pump Power for Pump 1, minimum (dBm) | column | INFINERA-TC-MIBFloatHundredths | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.22 |
| otsPtpPmOtsLpwr1Max OTS Laser Pump Power for Pump 1, maximum (dBm) | column | INFINERA-TC-MIBFloatHundredths | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.23 |
| otsPtpPmOtsLpwr1Ave OTS Laser Pump Power for Pump 1, average (dBm) | column | INFINERA-TC-MIBFloatHundredths | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.24 |
| otsPtpPmOtsLpwr2Min OTS Laser Pump Power for Pump 2, minimum (dBm) | column | INFINERA-TC-MIBFloatHundredths | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.25 |
| otsPtpPmOtsLpwr2Max OTS Laser Pump Power for Pump 2, maximum (dBm) | column | INFINERA-TC-MIBFloatHundredths | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.26 |
| otsPtpPmOtsLpwr2Ave OTS Laser Pump Power for Pump 2, average (dBm) | column | INFINERA-TC-MIBFloatHundredths | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.27 |
| otsPtpPmOtsLpwr3Min OTS Laser Pump Power for Pump 3, minimum (dBm) | column | INFINERA-TC-MIBFloatHundredths | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.28 |
| otsPtpPmOtsLpwr3Max OTS Laser Pump Power for Pump 3, maximum (dBm) | column | INFINERA-TC-MIBFloatHundredths | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.29 |
| otsPtpPmValidity Flag indicating if data was valid for the entire interval | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.3 |
| otsPtpPmOtsLpwr3Ave OTS Laser Pump Power for Pump 3, average (dBm) | column | INFINERA-TC-MIBFloatHundredths | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.30 |
| otsPtpPmOtsLpwr4Max OTS Laser Pump Power for Pump 4, maximum (dBm) | column | INFINERA-TC-MIBFloatHundredths | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.32 |
| otsPtpPmOtsLpwr4Ave OTS Laser Pump Power for Pump 4, average (dBm) | column | INFINERA-TC-MIBFloatHundredths | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.33 |
| otsPtpOtsAlsOprMin Optical power received by the ALS pilot laser, minimum (dBm). | column | INFINERA-TC-MIBFloatHundredths | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.34 |
| otsPtpOtsAlsOprMax Optical power received by the ALS pilot laser, maximum (dBm). | column | INFINERA-TC-MIBFloatHundredths | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.35 |
| otsPtpOtsAlsOprAve Optical power received by the ALS pilot laser, average (dBm). | column | INFINERA-TC-MIBFloatHundredths | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.36 |
| otsPtpOtsAlsOptMin Optical power transmitted by the ALS pilot laser, minimum (dBm). | column | INFINERA-TC-MIBFloatHundredths | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.37 |
| otsPtpOtsAlsOptMax Optical power transmitted by the ALS pilot laser, maximum (dBm). | column | INFINERA-TC-MIBFloatHundredths | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.38 |
| otsPtpOtsAlsOptAve Optical power transmitted by the ALS pilot laser, average (dBm). | column | INFINERA-TC-MIBFloatHundredths | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.39 |
| otsPtpPmOtsOptMin OTS Optical Power Transmitted, minimum (dBm) | column | INFINERA-TC-MIBFloatHundredths | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.4 |
| otsPtpOtsAlsLbcMin Laser biased current of the ALS pilot laser, minimum (dBm). | column | INFINERA-TC-MIBFloatHundredths | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.40 |
| otsPtpOtsAlsLbcMax Laser biased current of the ALS pilot laser, maximum (dBm). | column | INFINERA-TC-MIBFloatHundredths | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.41 |
| otsPtpOtsAlsLbcAve Laser biased current of the ALS pilot laser, average (dBm). | column | INFINERA-TC-MIBFloatHundredths | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.42 |
| otsPtpPmOtsOptMax OTS Optical Power Transmitted, maximum (dBm) | column | INFINERA-TC-MIBFloatHundredths | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.5 |
| otsPtpPmOtsOptAve OTS Optical Power Transmitted, average (dBm) | column | INFINERA-TC-MIBFloatHundredths | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.6 |
| otsPtpPmOtsOprMin OTS Optical Power Received, minimum (dBm) | column | INFINERA-TC-MIBFloatHundredths | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.7 |
| otsPtpPmOtsOprMax OTS Optical Power Received, maximum (dBm) | column | INFINERA-TC-MIBFloatHundredths | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.8 |
| otsPtpPmOtsOprAve OTS Optical Power Received, average (dBm) | column | INFINERA-TC-MIBFloatHundredths | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.9 |