INFINERA-PM-OTSPTP-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
2
Rows
2
Columns
59
otsPtpPmRealTable
table.1.3.6.1.4.1.21296.2.2.2.3.12.1
·
1 row entry
·
17 columns
Uses the infinera variant from
Command help
/opt/observium/mibs/infinera.
Walk otsPtpPmRealTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'INFINERA-PM-OTSPTP-MIB' -M '/opt/observium/mibs/infinera:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'INFINERA-PM-OTSPTP-MIB::otsPtpPmRealTable'
A list of OTSPtpPmReal entries. Each entry is uniquely identified by the value of ifIndex.
An OtsPTP entry containing real-time performance information pertaining to
Infinera OTS PTP Interfaces. This table is a subclass of IfCommon.
Entries will exist in this table only for interfaces of type OTS PTP.
Infinera OTS PTP Interfaces. This table is a subclass of IfCommon.
Entries will exist in this table only for interfaces of type OTS PTP.
| Column | Syntax | OID |
|---|---|---|
|
OTS Optical Power Transmitted
|
INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… |
.1.3.6.1.4.1.21296.2.2.2.3.12.1.1.1 |
|
OPT to OSA Tap Ratio.
|
INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… |
.1.3.6.1.4.1.21296.2.2.2.3.12.1.1.2 |
|
OTS Optical Power Received
|
INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… |
.1.3.6.1.4.1.21296.2.2.2.3.12.1.1.3 |
|
OPR to OSA Tap Ratio.
|
INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… |
.1.3.6.1.4.1.21296.2.2.2.3.12.1.1.4 |
|
OTS Laser Bias Current for Pump 1
|
INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… |
.1.3.6.1.4.1.21296.2.2.2.3.12.1.1.5 |
|
OTS Laser Bias Current for Pump 2
|
INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… |
.1.3.6.1.4.1.21296.2.2.2.3.12.1.1.6 |
|
OTS Laser Bias Current for Pump 3
|
INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… |
.1.3.6.1.4.1.21296.2.2.2.3.12.1.1.7 |
|
OTS Laser Bias Current for Pump 4
|
INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… |
.1.3.6.1.4.1.21296.2.2.2.3.12.1.1.8 |
|
OTS Laser Pump Power for Pump 1
|
INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… |
.1.3.6.1.4.1.21296.2.2.2.3.12.1.1.9 |
|
OTS Laser Pump Power for Pump 2
|
INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… |
.1.3.6.1.4.1.21296.2.2.2.3.12.1.1.10 |
|
OTS Laser Pump Power for Pump 3
|
INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… |
.1.3.6.1.4.1.21296.2.2.2.3.12.1.1.11 |
|
OTS Laser Pump Power for Pump 4
|
INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… |
.1.3.6.1.4.1.21296.2.2.2.3.12.1.1.12 |
|
Optical power received by the ALS pilot laser.
|
INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… |
.1.3.6.1.4.1.21296.2.2.2.3.12.1.1.13 |
|
Optical power transmitted by the ALS pilot laser.
|
INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… |
.1.3.6.1.4.1.21296.2.2.2.3.12.1.1.14 |
|
Laser biased current of the ALS pilot laser(dBm).
|
INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… |
.1.3.6.1.4.1.21296.2.2.2.3.12.1.1.15 |
|
Rx Post Edfa Osa Tap Ratio
|
INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… |
.1.3.6.1.4.1.21296.2.2.2.3.12.1.1.16 |
|
Operational Qualifier
|
SNMPv2-TCDisplayString Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… |
.1.3.6.1.4.1.21296.2.2.2.3.12.1.1.17 |
otsPtpPmTable
table.1.3.6.1.4.1.21296.2.2.2.3.12.2
·
1 row entry
·
42 columns
Uses the infinera variant from
Command help
/opt/observium/mibs/infinera.
Walk otsPtpPmTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'INFINERA-PM-OTSPTP-MIB' -M '/opt/observium/mibs/infinera:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'INFINERA-PM-OTSPTP-MIB::otsPtpPmTable'
A list of OTSPtpPm entries. Each entry is uniquely identified by the value of ifIndex, sampleDuration and otsPtpPmTimestamp.
An OtsPTP entry containing historical performance information pertaining to
Infinera OTS PTP Interfaces. This table is a subclass of IfCommon.
Entries will exist in this table only for interfaces of type OTS PTP.
Each i…
Infinera OTS PTP Interfaces. This table is a subclass of IfCommon.
Entries will exist in this table only for interfaces of type OTS PTP.
Each i…
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
End Time stamp for this interval. If this time is later than the current time,
then the data for this bucket is currently being collected. |
Integer32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.1 |
||||
|
The duration of this sample.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.2 |
||||
|
Flag indicating if data was valid for the entire interval
|
SNMPv2-TCTruthValue Type Values:
Description: Represents a boolean value. |
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.3 |
||||
|
OTS Optical Power Transmitted, minimum (dBm)
|
INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… |
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.4 |
||||
|
OTS Optical Power Transmitted, maximum (dBm)
|
INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… |
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.5 |
||||
|
OTS Optical Power Transmitted, average (dBm)
|
INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… |
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.6 |
||||
|
OTS Optical Power Received, minimum (dBm)
|
INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… |
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.7 |
||||
|
OTS Optical Power Received, maximum (dBm)
|
INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… |
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.8 |
||||
|
OTS Optical Power Received, average (dBm)
|
INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… |
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.9 |
||||
|
OTS Laser Bias Current for Pump 1, minimum (mA)
|
INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… |
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.10 |
||||
|
OTS Laser Bias Current for Pump 1, maximum (mA)
|
INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… |
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.11 |
||||
|
OTS Laser Bias Current for Pump 1, average (mA)
|
INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… |
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.12 |
||||
|
OTS Laser Bias Current for Pump 2, minimum (mA)
|
INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… |
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.13 |
||||
|
OTS Laser Bias Current for Pump 2, maximum (mA)
|
INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… |
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.14 |
||||
|
OTS Laser Bias Current for Pump 2, average (mA)
|
INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… |
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.15 |
||||
|
OTS Laser Bias Current for Pump 3, minimum (mA)
|
INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… |
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.16 |
||||
|
OTS Laser Bias Current for Pump 3, maximum (mA)
|
INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… |
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.17 |
||||
|
OTS Laser Bias Current for Pump 3, average (mA)
|
INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… |
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.18 |
||||
|
OTS Laser Bias Current for Pump 4, average (mA)
|
INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… |
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.19 |
||||
|
OTS Laser Bias Current for Pump 4, maximum (mA)
|
INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… |
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.20 |
||||
|
OTS Laser Bias Current for Pump 4, average (mA)
|
INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… |
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.21 |
||||
|
OTS Laser Pump Power for Pump 1, minimum (dBm)
|
INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… |
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.22 |
||||
|
OTS Laser Pump Power for Pump 1, maximum (dBm)
|
INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… |
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.23 |
||||
|
OTS Laser Pump Power for Pump 1, average (dBm)
|
INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… |
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.24 |
||||
|
OTS Laser Pump Power for Pump 2, minimum (dBm)
|
INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… |
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.25 |
||||
|
OTS Laser Pump Power for Pump 2, maximum (dBm)
|
INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… |
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.26 |
||||
|
OTS Laser Pump Power for Pump 2, average (dBm)
|
INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… |
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.27 |
||||
|
OTS Laser Pump Power for Pump 3, minimum (dBm)
|
INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… |
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.28 |
||||
|
OTS Laser Pump Power for Pump 3, maximum (dBm)
|
INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… |
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.29 |
||||
|
OTS Laser Pump Power for Pump 3, average (dBm)
|
INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… |
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.30 |
||||
|
OTS Laser Pump Power for Pump 4, minimum (dBm)
|
INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… |
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.31 |
||||
|
OTS Laser Pump Power for Pump 4, maximum (dBm)
|
INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… |
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.32 |
||||
|
OTS Laser Pump Power for Pump 4, average (dBm)
|
INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… |
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.33 |
||||
|
Optical power received by the ALS pilot laser, minimum (dBm).
|
INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… |
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.34 |
||||
|
Optical power received by the ALS pilot laser, maximum (dBm).
|
INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… |
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.35 |
||||
|
Optical power received by the ALS pilot laser, average (dBm).
|
INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… |
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.36 |
||||
|
Optical power transmitted by the ALS pilot laser, minimum (dBm).
|
INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… |
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.37 |
||||
|
Optical power transmitted by the ALS pilot laser, maximum (dBm).
|
INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… |
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.38 |
||||
|
Optical power transmitted by the ALS pilot laser, average (dBm).
|
INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… |
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.39 |
||||
|
Laser biased current of the ALS pilot laser, minimum (dBm).
|
INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… |
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.40 |
||||
|
Laser biased current of the ALS pilot laser, maximum (dBm).
|
INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… |
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.41 |
||||
|
Laser biased current of the ALS pilot laser, average (dBm).
|
INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… |
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.42 |