INFINERA-PM-OTSPTP-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
2
Rows
2
Columns
59
.1.3.6.1.4.1.21296.2.2.2.3.12.1 · 1 row entry · 17 columns
Uses the infinera variant from /opt/observium/mibs/infinera.
Command help
Walk otsPtpPmRealTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'INFINERA-PM-OTSPTP-MIB' -M '/opt/observium/mibs/infinera:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'INFINERA-PM-OTSPTP-MIB::otsPtpPmRealTable'
A list of OTSPtpPmReal entries. Each entry is uniquely identified by the value of ifIndex.
otsPtpPmRealEntry row .1.3.6.1.4.1.21296.2.2.2.3.12.1.1
An OtsPTP entry containing real-time performance information pertaining to
Infinera OTS PTP Interfaces. This table is a subclass of IfCommon.
Entries will exist in this table only for interfaces of type OTS PTP.
Indexes
Column Syntax OID
OTS Optical Power Transmitted
INFINERA-TC-MIBFloatHundredths
Description:
An integer representation of a fractional number. The transmitted value is the actual value
multiplied by 100 and rounded to the nearest Integer. The management station should divide
the transmitted value by 100 to deri…
.1.3.6.1.4.1.21296.2.2.2.3.12.1.1.1
OPT to OSA Tap Ratio.
INFINERA-TC-MIBFloatHundredths
Description:
An integer representation of a fractional number. The transmitted value is the actual value
multiplied by 100 and rounded to the nearest Integer. The management station should divide
the transmitted value by 100 to deri…
.1.3.6.1.4.1.21296.2.2.2.3.12.1.1.2
OTS Optical Power Received
INFINERA-TC-MIBFloatHundredths
Description:
An integer representation of a fractional number. The transmitted value is the actual value
multiplied by 100 and rounded to the nearest Integer. The management station should divide
the transmitted value by 100 to deri…
.1.3.6.1.4.1.21296.2.2.2.3.12.1.1.3
OPR to OSA Tap Ratio.
INFINERA-TC-MIBFloatHundredths
Description:
An integer representation of a fractional number. The transmitted value is the actual value
multiplied by 100 and rounded to the nearest Integer. The management station should divide
the transmitted value by 100 to deri…
.1.3.6.1.4.1.21296.2.2.2.3.12.1.1.4
OTS Laser Bias Current for Pump 1
INFINERA-TC-MIBFloatHundredths
Description:
An integer representation of a fractional number. The transmitted value is the actual value
multiplied by 100 and rounded to the nearest Integer. The management station should divide
the transmitted value by 100 to deri…
.1.3.6.1.4.1.21296.2.2.2.3.12.1.1.5
OTS Laser Bias Current for Pump 2
INFINERA-TC-MIBFloatHundredths
Description:
An integer representation of a fractional number. The transmitted value is the actual value
multiplied by 100 and rounded to the nearest Integer. The management station should divide
the transmitted value by 100 to deri…
.1.3.6.1.4.1.21296.2.2.2.3.12.1.1.6
OTS Laser Bias Current for Pump 3
INFINERA-TC-MIBFloatHundredths
Description:
An integer representation of a fractional number. The transmitted value is the actual value
multiplied by 100 and rounded to the nearest Integer. The management station should divide
the transmitted value by 100 to deri…
.1.3.6.1.4.1.21296.2.2.2.3.12.1.1.7
OTS Laser Bias Current for Pump 4
INFINERA-TC-MIBFloatHundredths
Description:
An integer representation of a fractional number. The transmitted value is the actual value
multiplied by 100 and rounded to the nearest Integer. The management station should divide
the transmitted value by 100 to deri…
.1.3.6.1.4.1.21296.2.2.2.3.12.1.1.8
OTS Laser Pump Power for Pump 1
INFINERA-TC-MIBFloatHundredths
Description:
An integer representation of a fractional number. The transmitted value is the actual value
multiplied by 100 and rounded to the nearest Integer. The management station should divide
the transmitted value by 100 to deri…
.1.3.6.1.4.1.21296.2.2.2.3.12.1.1.9
OTS Laser Pump Power for Pump 2
INFINERA-TC-MIBFloatHundredths
Description:
An integer representation of a fractional number. The transmitted value is the actual value
multiplied by 100 and rounded to the nearest Integer. The management station should divide
the transmitted value by 100 to deri…
.1.3.6.1.4.1.21296.2.2.2.3.12.1.1.10
OTS Laser Pump Power for Pump 3
INFINERA-TC-MIBFloatHundredths
Description:
An integer representation of a fractional number. The transmitted value is the actual value
multiplied by 100 and rounded to the nearest Integer. The management station should divide
the transmitted value by 100 to deri…
.1.3.6.1.4.1.21296.2.2.2.3.12.1.1.11
OTS Laser Pump Power for Pump 4
INFINERA-TC-MIBFloatHundredths
Description:
An integer representation of a fractional number. The transmitted value is the actual value
multiplied by 100 and rounded to the nearest Integer. The management station should divide
the transmitted value by 100 to deri…
.1.3.6.1.4.1.21296.2.2.2.3.12.1.1.12
Optical power received by the ALS pilot laser.
INFINERA-TC-MIBFloatHundredths
Description:
An integer representation of a fractional number. The transmitted value is the actual value
multiplied by 100 and rounded to the nearest Integer. The management station should divide
the transmitted value by 100 to deri…
.1.3.6.1.4.1.21296.2.2.2.3.12.1.1.13
Optical power transmitted by the ALS pilot laser.
INFINERA-TC-MIBFloatHundredths
Description:
An integer representation of a fractional number. The transmitted value is the actual value
multiplied by 100 and rounded to the nearest Integer. The management station should divide
the transmitted value by 100 to deri…
.1.3.6.1.4.1.21296.2.2.2.3.12.1.1.14
Laser biased current of the ALS pilot laser(dBm).
INFINERA-TC-MIBFloatHundredths
Description:
An integer representation of a fractional number. The transmitted value is the actual value
multiplied by 100 and rounded to the nearest Integer. The management station should divide
the transmitted value by 100 to deri…
.1.3.6.1.4.1.21296.2.2.2.3.12.1.1.15
Rx Post Edfa Osa Tap Ratio
INFINERA-TC-MIBFloatHundredths
Description:
An integer representation of a fractional number. The transmitted value is the actual value
multiplied by 100 and rounded to the nearest Integer. The management station should divide
the transmitted value by 100 to deri…
.1.3.6.1.4.1.21296.2.2.2.3.12.1.1.16
Operational Qualifier
SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.21296.2.2.2.3.12.1.1.17
.1.3.6.1.4.1.21296.2.2.2.3.12.2 · 1 row entry · 42 columns
Uses the infinera variant from /opt/observium/mibs/infinera.
Command help
Walk otsPtpPmTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'INFINERA-PM-OTSPTP-MIB' -M '/opt/observium/mibs/infinera:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'INFINERA-PM-OTSPTP-MIB::otsPtpPmTable'
A list of OTSPtpPm entries. Each entry is uniquely identified by the value of ifIndex, sampleDuration and otsPtpPmTimestamp.
otsPtpPmEntry row .1.3.6.1.4.1.21296.2.2.2.3.12.2.1
An OtsPTP entry containing historical performance information pertaining to
Infinera OTS PTP Interfaces. This table is a subclass of IfCommon.
Entries will exist in this table only for interfaces of type OTS PTP.
Each i…
Column Syntax OID
End Time stamp for this interval. If this time is later than the current time,
then the data for this bucket is currently being collected.
Integer32
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.1
The duration of this sample.
Enumeration
Enumerated Values:
1fifteenMinutes
2day
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.2
Flag indicating if data was valid for the entire interval
SNMPv2-TCTruthValue
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.3
OTS Optical Power Transmitted, minimum (dBm)
INFINERA-TC-MIBFloatHundredths
Description:
An integer representation of a fractional number. The transmitted value is the actual value
multiplied by 100 and rounded to the nearest Integer. The management station should divide
the transmitted value by 100 to deri…
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.4
OTS Optical Power Transmitted, maximum (dBm)
INFINERA-TC-MIBFloatHundredths
Description:
An integer representation of a fractional number. The transmitted value is the actual value
multiplied by 100 and rounded to the nearest Integer. The management station should divide
the transmitted value by 100 to deri…
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.5
OTS Optical Power Transmitted, average (dBm)
INFINERA-TC-MIBFloatHundredths
Description:
An integer representation of a fractional number. The transmitted value is the actual value
multiplied by 100 and rounded to the nearest Integer. The management station should divide
the transmitted value by 100 to deri…
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.6
OTS Optical Power Received, minimum (dBm)
INFINERA-TC-MIBFloatHundredths
Description:
An integer representation of a fractional number. The transmitted value is the actual value
multiplied by 100 and rounded to the nearest Integer. The management station should divide
the transmitted value by 100 to deri…
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.7
OTS Optical Power Received, maximum (dBm)
INFINERA-TC-MIBFloatHundredths
Description:
An integer representation of a fractional number. The transmitted value is the actual value
multiplied by 100 and rounded to the nearest Integer. The management station should divide
the transmitted value by 100 to deri…
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.8
OTS Optical Power Received, average (dBm)
INFINERA-TC-MIBFloatHundredths
Description:
An integer representation of a fractional number. The transmitted value is the actual value
multiplied by 100 and rounded to the nearest Integer. The management station should divide
the transmitted value by 100 to deri…
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.9
OTS Laser Bias Current for Pump 1, minimum (mA)
INFINERA-TC-MIBFloatHundredths
Description:
An integer representation of a fractional number. The transmitted value is the actual value
multiplied by 100 and rounded to the nearest Integer. The management station should divide
the transmitted value by 100 to deri…
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.10
OTS Laser Bias Current for Pump 1, maximum (mA)
INFINERA-TC-MIBFloatHundredths
Description:
An integer representation of a fractional number. The transmitted value is the actual value
multiplied by 100 and rounded to the nearest Integer. The management station should divide
the transmitted value by 100 to deri…
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.11
OTS Laser Bias Current for Pump 1, average (mA)
INFINERA-TC-MIBFloatHundredths
Description:
An integer representation of a fractional number. The transmitted value is the actual value
multiplied by 100 and rounded to the nearest Integer. The management station should divide
the transmitted value by 100 to deri…
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.12
OTS Laser Bias Current for Pump 2, minimum (mA)
INFINERA-TC-MIBFloatHundredths
Description:
An integer representation of a fractional number. The transmitted value is the actual value
multiplied by 100 and rounded to the nearest Integer. The management station should divide
the transmitted value by 100 to deri…
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.13
OTS Laser Bias Current for Pump 2, maximum (mA)
INFINERA-TC-MIBFloatHundredths
Description:
An integer representation of a fractional number. The transmitted value is the actual value
multiplied by 100 and rounded to the nearest Integer. The management station should divide
the transmitted value by 100 to deri…
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.14
OTS Laser Bias Current for Pump 2, average (mA)
INFINERA-TC-MIBFloatHundredths
Description:
An integer representation of a fractional number. The transmitted value is the actual value
multiplied by 100 and rounded to the nearest Integer. The management station should divide
the transmitted value by 100 to deri…
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.15
OTS Laser Bias Current for Pump 3, minimum (mA)
INFINERA-TC-MIBFloatHundredths
Description:
An integer representation of a fractional number. The transmitted value is the actual value
multiplied by 100 and rounded to the nearest Integer. The management station should divide
the transmitted value by 100 to deri…
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.16
OTS Laser Bias Current for Pump 3, maximum (mA)
INFINERA-TC-MIBFloatHundredths
Description:
An integer representation of a fractional number. The transmitted value is the actual value
multiplied by 100 and rounded to the nearest Integer. The management station should divide
the transmitted value by 100 to deri…
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.17
OTS Laser Bias Current for Pump 3, average (mA)
INFINERA-TC-MIBFloatHundredths
Description:
An integer representation of a fractional number. The transmitted value is the actual value
multiplied by 100 and rounded to the nearest Integer. The management station should divide
the transmitted value by 100 to deri…
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.18
OTS Laser Bias Current for Pump 4, average (mA)
INFINERA-TC-MIBFloatHundredths
Description:
An integer representation of a fractional number. The transmitted value is the actual value
multiplied by 100 and rounded to the nearest Integer. The management station should divide
the transmitted value by 100 to deri…
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.19
OTS Laser Bias Current for Pump 4, maximum (mA)
INFINERA-TC-MIBFloatHundredths
Description:
An integer representation of a fractional number. The transmitted value is the actual value
multiplied by 100 and rounded to the nearest Integer. The management station should divide
the transmitted value by 100 to deri…
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.20
OTS Laser Bias Current for Pump 4, average (mA)
INFINERA-TC-MIBFloatHundredths
Description:
An integer representation of a fractional number. The transmitted value is the actual value
multiplied by 100 and rounded to the nearest Integer. The management station should divide
the transmitted value by 100 to deri…
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.21
OTS Laser Pump Power for Pump 1, minimum (dBm)
INFINERA-TC-MIBFloatHundredths
Description:
An integer representation of a fractional number. The transmitted value is the actual value
multiplied by 100 and rounded to the nearest Integer. The management station should divide
the transmitted value by 100 to deri…
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.22
OTS Laser Pump Power for Pump 1, maximum (dBm)
INFINERA-TC-MIBFloatHundredths
Description:
An integer representation of a fractional number. The transmitted value is the actual value
multiplied by 100 and rounded to the nearest Integer. The management station should divide
the transmitted value by 100 to deri…
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.23
OTS Laser Pump Power for Pump 1, average (dBm)
INFINERA-TC-MIBFloatHundredths
Description:
An integer representation of a fractional number. The transmitted value is the actual value
multiplied by 100 and rounded to the nearest Integer. The management station should divide
the transmitted value by 100 to deri…
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.24
OTS Laser Pump Power for Pump 2, minimum (dBm)
INFINERA-TC-MIBFloatHundredths
Description:
An integer representation of a fractional number. The transmitted value is the actual value
multiplied by 100 and rounded to the nearest Integer. The management station should divide
the transmitted value by 100 to deri…
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.25
OTS Laser Pump Power for Pump 2, maximum (dBm)
INFINERA-TC-MIBFloatHundredths
Description:
An integer representation of a fractional number. The transmitted value is the actual value
multiplied by 100 and rounded to the nearest Integer. The management station should divide
the transmitted value by 100 to deri…
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.26
OTS Laser Pump Power for Pump 2, average (dBm)
INFINERA-TC-MIBFloatHundredths
Description:
An integer representation of a fractional number. The transmitted value is the actual value
multiplied by 100 and rounded to the nearest Integer. The management station should divide
the transmitted value by 100 to deri…
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.27
OTS Laser Pump Power for Pump 3, minimum (dBm)
INFINERA-TC-MIBFloatHundredths
Description:
An integer representation of a fractional number. The transmitted value is the actual value
multiplied by 100 and rounded to the nearest Integer. The management station should divide
the transmitted value by 100 to deri…
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.28
OTS Laser Pump Power for Pump 3, maximum (dBm)
INFINERA-TC-MIBFloatHundredths
Description:
An integer representation of a fractional number. The transmitted value is the actual value
multiplied by 100 and rounded to the nearest Integer. The management station should divide
the transmitted value by 100 to deri…
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.29
OTS Laser Pump Power for Pump 3, average (dBm)
INFINERA-TC-MIBFloatHundredths
Description:
An integer representation of a fractional number. The transmitted value is the actual value
multiplied by 100 and rounded to the nearest Integer. The management station should divide
the transmitted value by 100 to deri…
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.30
OTS Laser Pump Power for Pump 4, minimum (dBm)
INFINERA-TC-MIBFloatHundredths
Description:
An integer representation of a fractional number. The transmitted value is the actual value
multiplied by 100 and rounded to the nearest Integer. The management station should divide
the transmitted value by 100 to deri…
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.31
OTS Laser Pump Power for Pump 4, maximum (dBm)
INFINERA-TC-MIBFloatHundredths
Description:
An integer representation of a fractional number. The transmitted value is the actual value
multiplied by 100 and rounded to the nearest Integer. The management station should divide
the transmitted value by 100 to deri…
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.32
OTS Laser Pump Power for Pump 4, average (dBm)
INFINERA-TC-MIBFloatHundredths
Description:
An integer representation of a fractional number. The transmitted value is the actual value
multiplied by 100 and rounded to the nearest Integer. The management station should divide
the transmitted value by 100 to deri…
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.33
Optical power received by the ALS pilot laser, minimum (dBm).
INFINERA-TC-MIBFloatHundredths
Description:
An integer representation of a fractional number. The transmitted value is the actual value
multiplied by 100 and rounded to the nearest Integer. The management station should divide
the transmitted value by 100 to deri…
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.34
Optical power received by the ALS pilot laser, maximum (dBm).
INFINERA-TC-MIBFloatHundredths
Description:
An integer representation of a fractional number. The transmitted value is the actual value
multiplied by 100 and rounded to the nearest Integer. The management station should divide
the transmitted value by 100 to deri…
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.35
Optical power received by the ALS pilot laser, average (dBm).
INFINERA-TC-MIBFloatHundredths
Description:
An integer representation of a fractional number. The transmitted value is the actual value
multiplied by 100 and rounded to the nearest Integer. The management station should divide
the transmitted value by 100 to deri…
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.36
Optical power transmitted by the ALS pilot laser, minimum (dBm).
INFINERA-TC-MIBFloatHundredths
Description:
An integer representation of a fractional number. The transmitted value is the actual value
multiplied by 100 and rounded to the nearest Integer. The management station should divide
the transmitted value by 100 to deri…
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.37
Optical power transmitted by the ALS pilot laser, maximum (dBm).
INFINERA-TC-MIBFloatHundredths
Description:
An integer representation of a fractional number. The transmitted value is the actual value
multiplied by 100 and rounded to the nearest Integer. The management station should divide
the transmitted value by 100 to deri…
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.38
Optical power transmitted by the ALS pilot laser, average (dBm).
INFINERA-TC-MIBFloatHundredths
Description:
An integer representation of a fractional number. The transmitted value is the actual value
multiplied by 100 and rounded to the nearest Integer. The management station should divide
the transmitted value by 100 to deri…
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.39
Laser biased current of the ALS pilot laser, minimum (dBm).
INFINERA-TC-MIBFloatHundredths
Description:
An integer representation of a fractional number. The transmitted value is the actual value
multiplied by 100 and rounded to the nearest Integer. The management station should divide
the transmitted value by 100 to deri…
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.40
Laser biased current of the ALS pilot laser, maximum (dBm).
INFINERA-TC-MIBFloatHundredths
Description:
An integer representation of a fractional number. The transmitted value is the actual value
multiplied by 100 and rounded to the nearest Integer. The management station should divide
the transmitted value by 100 to deri…
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.41
Laser biased current of the ALS pilot laser, average (dBm).
INFINERA-TC-MIBFloatHundredths
Description:
An integer representation of a fractional number. The transmitted value is the actual value
multiplied by 100 and rounded to the nearest Integer. The management station should divide
the transmitted value by 100 to deri…
.1.3.6.1.4.1.21296.2.2.2.3.12.2.1.42