INFINERA-PM-OTSPTP-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
2
Rows
2
Columns
59
otsPtpPmRealTable
table.1.3.6.1.4.1.21296.2.2.2.3.12.1
·
1 row entry
·
17 columns
Uses the infinera variant from
Command help
/opt/observium/mibs/infinera.
Walk otsPtpPmRealTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'INFINERA-PM-OTSPTP-MIB' -M '/opt/observium/mibs/infinera:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'INFINERA-PM-OTSPTP-MIB::otsPtpPmRealTable'
A list of OTSPtpPmReal entries. Each entry is uniquely identified by the value of ifIndex.
An OtsPTP entry containing real-time performance information pertaining to
Infinera OTS PTP Interfaces. This table is a subclass of IfCommon.
Entries will exist in this table only for interfaces of type OTS PTP.
Infinera OTS PTP Interfaces. This table is a subclass of IfCommon.
Entries will exist in this table only for interfaces of type OTS PTP.
| Column | Syntax | OID |
|---|---|---|
| otsPtpPmRealOtsOptOTS Optical Power Transmitted | INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… | .1.3.6.1.4.1.21296.2.2.2.3.12.1.1.1 |
| otsPtpPmRealOtsOptOsaTapRatioOPT to OSA Tap Ratio. | INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… | .1.3.6.1.4.1.21296.2.2.2.3.12.1.1.2 |
| otsPtpPmRealOtsOprOTS Optical Power Received | INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… | .1.3.6.1.4.1.21296.2.2.2.3.12.1.1.3 |
| otsPtpPmRealOtsOprOsaTapRatioOPR to OSA Tap Ratio. | INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… | .1.3.6.1.4.1.21296.2.2.2.3.12.1.1.4 |
| otsPtpPmRealOtsLbc1OTS Laser Bias Current for Pump 1 | INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… | .1.3.6.1.4.1.21296.2.2.2.3.12.1.1.5 |
| otsPtpPmRealOtsLbc2OTS Laser Bias Current for Pump 2 | INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… | .1.3.6.1.4.1.21296.2.2.2.3.12.1.1.6 |
| otsPtpPmRealOtsLbc3OTS Laser Bias Current for Pump 3 | INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… | .1.3.6.1.4.1.21296.2.2.2.3.12.1.1.7 |
| otsPtpPmRealOtsLbc4OTS Laser Bias Current for Pump 4 | INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… | .1.3.6.1.4.1.21296.2.2.2.3.12.1.1.8 |
| otsPtpPmRealOtsLpwr1OTS Laser Pump Power for Pump 1 | INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… | .1.3.6.1.4.1.21296.2.2.2.3.12.1.1.9 |
| otsPtpPmRealOtsLpwr2OTS Laser Pump Power for Pump 2 | INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… | .1.3.6.1.4.1.21296.2.2.2.3.12.1.1.10 |
| otsPtpPmRealOtsLpwr3OTS Laser Pump Power for Pump 3 | INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… | .1.3.6.1.4.1.21296.2.2.2.3.12.1.1.11 |
| otsPtpPmRealOtsLpwr4OTS Laser Pump Power for Pump 4 | INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… | .1.3.6.1.4.1.21296.2.2.2.3.12.1.1.12 |
| otsPtpPmRealOtsAlsOprOptical power received by the ALS pilot laser. | INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… | .1.3.6.1.4.1.21296.2.2.2.3.12.1.1.13 |
| otsPtpPmRealOtsAlsOptOptical power transmitted by the ALS pilot laser. | INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… | .1.3.6.1.4.1.21296.2.2.2.3.12.1.1.14 |
| otsPtpPmRealOtsAlsLbcLaser biased current of the ALS pilot laser(dBm). | INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… | .1.3.6.1.4.1.21296.2.2.2.3.12.1.1.15 |
| otsPtpPmRealRxPostEdfaOsaTapRatioRx Post Edfa Osa Tap Ratio | INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… | .1.3.6.1.4.1.21296.2.2.2.3.12.1.1.16 |
| otsPtpPmRealOprQOperational Qualifier | SNMPv2-TCDisplayString Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… | .1.3.6.1.4.1.21296.2.2.2.3.12.1.1.17 |
otsPtpPmTable
table.1.3.6.1.4.1.21296.2.2.2.3.12.2
·
1 row entry
·
42 columns
Uses the infinera variant from
Command help
/opt/observium/mibs/infinera.
Walk otsPtpPmTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'INFINERA-PM-OTSPTP-MIB' -M '/opt/observium/mibs/infinera:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'INFINERA-PM-OTSPTP-MIB::otsPtpPmTable'
A list of OTSPtpPm entries. Each entry is uniquely identified by the value of ifIndex, sampleDuration and otsPtpPmTimestamp.
An OtsPTP entry containing historical performance information pertaining to
Infinera OTS PTP Interfaces. This table is a subclass of IfCommon.
Entries will exist in this table only for interfaces of type OTS PTP.
Each i…
Infinera OTS PTP Interfaces. This table is a subclass of IfCommon.
Entries will exist in this table only for interfaces of type OTS PTP.
Each i…
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
| otsPtpPmTimestampEnd Time stamp for this interval. If this time is later than the current time, then the data for this bucket is currently being collected. | Integer32 Constraints: range: 0-2147483647 | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.1 | ||||
| otsPtpPmSampleDurationThe duration of this sample. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.2 | ||||
| otsPtpPmValidityFlag indicating if data was valid for the entire interval | SNMPv2-TCTruthValue Type Values:
Description: Represents a boolean value. | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.3 | ||||
| otsPtpPmOtsOptMinOTS Optical Power Transmitted, minimum (dBm) | INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.4 | ||||
| otsPtpPmOtsOptMaxOTS Optical Power Transmitted, maximum (dBm) | INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.5 | ||||
| otsPtpPmOtsOptAveOTS Optical Power Transmitted, average (dBm) | INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.6 | ||||
| otsPtpPmOtsOprMinOTS Optical Power Received, minimum (dBm) | INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.7 | ||||
| otsPtpPmOtsOprMaxOTS Optical Power Received, maximum (dBm) | INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.8 | ||||
| otsPtpPmOtsOprAveOTS Optical Power Received, average (dBm) | INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.9 | ||||
| otsPtpPmOtsLbc1MinOTS Laser Bias Current for Pump 1, minimum (mA) | INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.10 | ||||
| otsPtpPmOtsLbc1MaxOTS Laser Bias Current for Pump 1, maximum (mA) | INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.11 | ||||
| otsPtpPmOtsLbc1AveOTS Laser Bias Current for Pump 1, average (mA) | INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.12 | ||||
| otsPtpPmOtsLbc2MinOTS Laser Bias Current for Pump 2, minimum (mA) | INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.13 | ||||
| otsPtpPmOtsLbc2MaxOTS Laser Bias Current for Pump 2, maximum (mA) | INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.14 | ||||
| otsPtpPmOtsLbc2AveOTS Laser Bias Current for Pump 2, average (mA) | INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.15 | ||||
| otsPtpPmOtsLbc3MinOTS Laser Bias Current for Pump 3, minimum (mA) | INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.16 | ||||
| otsPtpPmOtsLbc3MaxOTS Laser Bias Current for Pump 3, maximum (mA) | INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.17 | ||||
| otsPtpPmOtsLbc3AveOTS Laser Bias Current for Pump 3, average (mA) | INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.18 | ||||
| otsPtpPmOtsLbc4MinOTS Laser Bias Current for Pump 4, average (mA) | INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.19 | ||||
| otsPtpPmOtsLbc4MaxOTS Laser Bias Current for Pump 4, maximum (mA) | INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.20 | ||||
| otsPtpPmOtsLbc4AveOTS Laser Bias Current for Pump 4, average (mA) | INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.21 | ||||
| otsPtpPmOtsLpwr1MinOTS Laser Pump Power for Pump 1, minimum (dBm) | INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.22 | ||||
| otsPtpPmOtsLpwr1MaxOTS Laser Pump Power for Pump 1, maximum (dBm) | INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.23 | ||||
| otsPtpPmOtsLpwr1AveOTS Laser Pump Power for Pump 1, average (dBm) | INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.24 | ||||
| otsPtpPmOtsLpwr2MinOTS Laser Pump Power for Pump 2, minimum (dBm) | INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.25 | ||||
| otsPtpPmOtsLpwr2MaxOTS Laser Pump Power for Pump 2, maximum (dBm) | INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.26 | ||||
| otsPtpPmOtsLpwr2AveOTS Laser Pump Power for Pump 2, average (dBm) | INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.27 | ||||
| otsPtpPmOtsLpwr3MinOTS Laser Pump Power for Pump 3, minimum (dBm) | INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.28 | ||||
| otsPtpPmOtsLpwr3MaxOTS Laser Pump Power for Pump 3, maximum (dBm) | INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.29 | ||||
| otsPtpPmOtsLpwr3AveOTS Laser Pump Power for Pump 3, average (dBm) | INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.30 | ||||
| otsPtpPmOtsLpwr4MinOTS Laser Pump Power for Pump 4, minimum (dBm) | INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.31 | ||||
| otsPtpPmOtsLpwr4MaxOTS Laser Pump Power for Pump 4, maximum (dBm) | INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.32 | ||||
| otsPtpPmOtsLpwr4AveOTS Laser Pump Power for Pump 4, average (dBm) | INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.33 | ||||
| otsPtpOtsAlsOprMinOptical power received by the ALS pilot laser, minimum (dBm). | INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.34 | ||||
| otsPtpOtsAlsOprMaxOptical power received by the ALS pilot laser, maximum (dBm). | INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.35 | ||||
| otsPtpOtsAlsOprAveOptical power received by the ALS pilot laser, average (dBm). | INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.36 | ||||
| otsPtpOtsAlsOptMinOptical power transmitted by the ALS pilot laser, minimum (dBm). | INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.37 | ||||
| otsPtpOtsAlsOptMaxOptical power transmitted by the ALS pilot laser, maximum (dBm). | INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.38 | ||||
| otsPtpOtsAlsOptAveOptical power transmitted by the ALS pilot laser, average (dBm). | INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.39 | ||||
| otsPtpOtsAlsLbcMinLaser biased current of the ALS pilot laser, minimum (dBm). | INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.40 | ||||
| otsPtpOtsAlsLbcMaxLaser biased current of the ALS pilot laser, maximum (dBm). | INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.41 | ||||
| otsPtpOtsAlsLbcAveLaser biased current of the ALS pilot laser, average (dBm). | INFINERA-TC-MIBFloatHundredths Description: An integer representation of a fractional number. The transmitted value is the actual value multiplied by 100 and rounded to the nearest Integer. The management station should divide the transmitted value by 100 to deri… | .1.3.6.1.4.1.21296.2.2.2.3.12.2.1.42 |