ieee8021QBridgeFdbAgingTime
IEEE8021-Q-BRIDGE-MIB ·
.1.3.111.2.802.1.1.4.1.2.1.1.5
Object
column
r/w
seconds Integer32
The timeout period in seconds for aging out
dynamically-learned forwarding information.
IEEE Std 802.1D-1998 recommends a default of 300 seconds.
The value of this object MUST be retained across
reinitializations of the management system.
Context
- MIB
- IEEE8021-Q-BRIDGE-MIB
- OID
.1.3.111.2.802.1.1.4.1.2.1.1.5- Type
- column
- Access
- readwrite
- Status
- current
- Units
- seconds
- Parent
- ieee8021QBridgeFdbEntry
- Table
- ieee8021QBridgeFdbTable
- Siblings
- 4
Syntax
seconds Integer32
Values & Constraints
Object Constraints
range: 10-1000000
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| ieee8021QBridgeFdbComponentId The component identifier is used to distinguish between the
multiple virtual Bridge instances within a PBB. In simple
situations where there is only a single component the defaul… | column | IEEE8021-TC-MIBIEEE8021PbbComponentIdentifier | .1.3.111.2.802.1.1.4.1.2.1.1.1 |
| ieee8021QBridgeFdbId The identity of this Filtering Database. | column | Unsigned32 | .1.3.111.2.802.1.1.4.1.2.1.1.2 |
| ieee8021QBridgeFdbDynamicCount The current number of dynamic entries in this
Filtering Database. | column | database entries SNMPv2-SMIGauge32 | .1.3.111.2.802.1.1.4.1.2.1.1.3 |
| ieee8021QBridgeFdbLearnedEntryDiscards The total number of Filtering Database entries that
have been or would have been learned, but have been
discarded due to a lack of storage space in the
Filtering Database. If thi… | column | database entries SNMPv2-SMICounter64 | .1.3.111.2.802.1.1.4.1.2.1.1.4 |