ieee8021PSFPAdminControlList
IEEE8021-PSFP-MIB ·
.1.3.111.2.802.1.1.31.1.2.1.1.7
Object
column
r/w
OctetString
The administrative value of the ControlList parameter for the gate.
The octet string value represents the contents of the control list as
an ordered list of entries, each encoded as a TLV, as follows.
The first octet of each TLV is interpreted as an
unsigned integer representing a gate operation name:
0: SetGateAndIPV
1-255: Reserved for future gate operations
The second octet of the TLV is the length field,
interpreted as an unsigned integer, indicating the number of
octets of the value that follows the length. A length of
zero indicates that there is no value
(i.e., the gate operation has no parameters).
The third through (3 + length -1)th octets encode the
parameters of the gate operation, in the order that they
appear in the definition of the operation
in Table 8-4. Three parameter types are defined:
- StreamGateState:
A GateState parameter is encoded in a single octet, and
is interpreted as an integer value.
The value 1 indicates open; the value 2 indicates closed.
- IPV:
An IPV is encoded in four octets as a 32-bit
signed integer. A negative denotes the null value;
zero or positive values denote internal priority values.
- TimeInterval:
A TimeInterval is encoded in 4 octets as a 32-bit
unsigned integer, representing a number of nanoseconds.
The first octet encodes the most significant 8 bits of the
integer, and the fourth octet encodes the least
significant 8 bits.
- IntervalOctetMax:
An integer representing the maximum number of MSDU octets
that are permitted to pas the gate during the specified
TimeInterval. If this parameter is omitted, there is
no maximum.
The value of this object MUST be retained across
reinitializations of the management system.
Context
- MIB
- IEEE8021-PSFP-MIB
- OID
.1.3.111.2.802.1.1.31.1.2.1.1.7- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- ieee8021PSFPStreamGateEntry
Syntax
OctetString
Values & Constraints
No enumerated values or constraints recorded.