IEEE8021-PSFP-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
4
Rows
4
Columns
58
.1.3.111.2.802.1.1.31.1.1.1 · 1 row entry · 14 columns
Uses the rfc variant from /opt/observium/mibs/rfc.
Command help
Walk ieee8021PSFPStreamFilterTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'IEEE8021-PSFP-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'IEEE8021-PSFP-MIB::ieee8021PSFPStreamFilterTable'
A table that contains the per-filter instance
manageable parameters for stream filters.
          
A row in the table exists for each stream filter instance.
associated with a Bridge component.
          
All writable objects in this table must be
persistent over power up restart/reboot.
ieee8021PSFPStreamFilterEntry row .1.3.111.2.802.1.1.31.1.1.1.1
A list of objects that contains the manageable parameters for
stream filters for a Bridge component.
Column Syntax OID
The StreamFilterInstance parameter is an index into the
StreamFilterTable.

The value of this object MUST be retained across
reinitializations of the management system.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.111.2.802.1.1.31.1.1.1.1.1
The StreamHandleSpec parameter contains a stream identifier
specification value. A value of -1 denotes the wild card value;
all positive values denote stream identifier values.

The value of this object M…
Integer32r/w
Constraints:
range: -1-2147483647
.1.3.111.2.802.1.1.31.1.1.1.1.2
The PrioritySpec parameter contains a priority
specification value. A value of -1 denotes the wild card value;
zero or positive values denote priority values.

The value of this object MUST be retained ac…
Integer32r/w
Constraints:
range: -1-2147483647
.1.3.111.2.802.1.1.31.1.1.1.1.3
The StreamGateInstance parameter contains the index of an
entry in the Stream Gate Table.

The value of this object MUST be retained across
reinitializations of the management system.
SNMPv2-SMIUnsigned32r/w
Type Constraints:
range: 0..4294967295
.1.3.111.2.802.1.1.31.1.1.1.1.4
The FilterSpecificationList parameter contains a list of
filter specifications associated with this stream filter.

The octet string value represents the contents of the list as
an ordered list of entrie…
OctetStringr/w .1.3.111.2.802.1.1.31.1.1.1.1.5
The MatchingFramesCount counter counts received frames that
match this stream filter.
SNMPv2-SMICounter64
Type Constraints:
range: 0..18446744073709551615
.1.3.111.2.802.1.1.31.1.1.1.1.6
The PassingFramesCount counter counts received frames that
pass the gate associated with this stream filter.
SNMPv2-SMICounter64
Type Constraints:
range: 0..18446744073709551615
.1.3.111.2.802.1.1.31.1.1.1.1.7
The NotPassingFramesCount counter counts received frames that
do not pass the gate associated
with this stream filter.
SNMPv2-SMICounter64
Type Constraints:
range: 0..18446744073709551615
.1.3.111.2.802.1.1.31.1.1.1.1.8
The PassingSDUCount counter counts received frames that
pass the SDU size filter specification associated
with this stream filter.
SNMPv2-SMICounter64
Type Constraints:
range: 0..18446744073709551615
.1.3.111.2.802.1.1.31.1.1.1.1.9
The NotPassingSDUCount counter counts received frames that
do not pass the SDU size filter specification associated
with this stream filter.
SNMPv2-SMICounter64
Type Constraints:
range: 0..18446744073709551615
.1.3.111.2.802.1.1.31.1.1.1.1.10
The REDFramesCount counter counts received
frames that were discarded as a result of the
operation of the flow meter.
SNMPv2-SMICounter64
Type Constraints:
range: 0..18446744073709551615
.1.3.111.2.802.1.1.31.1.1.1.1.11
The ieee8021PSFPStreamBlockedDueToOversizeFrameEnable object
contains a Boolean value that indicates whether the
ieee8021PSFPStreamBlockedDueToOversizeFrame function is
enabled (TRUE) or disabled (FALSE).
SNMPv2-TCTruthValuer/w
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.111.2.802.1.1.31.1.1.1.1.12
The ieee8021PSFPStreamBlockedDueToOversizeFrame object
contains a Boolean value that indicates whether, if the
ieee8021PSFPStreamBlockedDueToOversizeFrame function is
enabled, all frames are to be discarded (TRUE)
or…
SNMPv2-TCTruthValuer/w
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.111.2.802.1.1.31.1.1.1.1.13
The status of the row.

The writable columns in a row cannot be changed if the row
is active. All columns MUST have a valid value before a row
can be activated.
SNMPv2-TCRowStatusr/w
Type Values:
1active
2notInService
3notReady
4createAndGo
5createAndWait
6destroy
Description:
The RowStatus textual convention is used to manage the
creation and deletion of conceptual rows, and is used as the
value of the SYNTAX clause for the status column of a
conceptual row (as described in Section 7.7.1 of …
.1.3.111.2.802.1.1.31.1.1.1.1.14
.1.3.111.2.802.1.1.31.1.2.1 · 1 row entry · 29 columns
Uses the rfc variant from /opt/observium/mibs/rfc.
Command help
Walk ieee8021PSFPStreamGateTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'IEEE8021-PSFP-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'IEEE8021-PSFP-MIB::ieee8021PSFPStreamGateTable'
A table that contains the per-gate instance
manageable parameters for stream gate scheduling.
          
For a given Bridge component, a row in the table exists for
each stream gate instance.
          
All writable objects in this table must be
persistent over power up restart/reboot.
ieee8021PSFPStreamGateEntry row .1.3.111.2.802.1.1.31.1.2.1.1
A list of objects that contains the manageable parameters for
stream gate scheduling for a Bridge component.
Column Syntax OID
The StreamGateInstance parameter is an index into the
StreamGateTable.

The value of this object MUST be retained across
reinitializations of the management system.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.111.2.802.1.1.31.1.2.1.1.1
The GateEnabled parameter determines whether the stream gate
is active (true) or inactive (false).

The value of this object MUST be retained across
reinitializations of the management system.
SNMPv2-TCTruthValuer/w
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.111.2.802.1.1.31.1.2.1.1.2
The administrative value of the GateStates parameter for the
stream gate.
The open value indicates that the gate is open,
the closed value indicates that the gate is closed.

The value of this object MUST…
Enumerationr/w
Enumerated Values:
1open
2closed
.1.3.111.2.802.1.1.31.1.2.1.1.3
The operational value of the GateStates parameter for the
stream gate.
The open value indicates that the gate is open,
the closed value indicates that the gate is closed.
Enumeration
Enumerated Values:
1open
2closed
.1.3.111.2.802.1.1.31.1.2.1.1.4
The administrative value of the ListMax parameter for the gate.
The integer value indicates the number of entries (TLVs) in the
AdminControlList.

The value of this object MUST be retained across
reinitial…
SNMPv2-SMIUnsigned32r/w
Type Constraints:
range: 0..4294967295
.1.3.111.2.802.1.1.31.1.2.1.1.5
The operational value of the ListMax parameter for the gate.
The integer value indicates the number of entries (TLVs) in the
OperControlList.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.111.2.802.1.1.31.1.2.1.1.6
The administrative value of the ControlList parameter for the gate.
The octet string value represents the contents of the control list as
an ordered list of entries, each encoded as a TLV, as follows.
The first octet o…
OctetStringr/w .1.3.111.2.802.1.1.31.1.2.1.1.7
The operational value of the ControlList parameter for the gate.
The octet string value represents the contents of the control list as
an ordered list of entries, each encoded as a TLV, as follows.
The first octet of e…
OctetString .1.3.111.2.802.1.1.31.1.2.1.1.8
The administrative value of the numerator of the CycleTime
parameter for the gate.
The numerator and denominator together represent the cycle time as
a rational number of seconds.

The value of this object…
SNMPv2-SMIUnsigned32r/w
Type Constraints:
range: 0..4294967295
.1.3.111.2.802.1.1.31.1.2.1.1.9
The administrative value of the denominator of the
CycleTime parameter for the gate.
The numerator and denominator together represent the cycle time as
a rational number of seconds.

The value of this obj…
SNMPv2-SMIUnsigned32r/w
Type Constraints:
range: 0..4294967295
.1.3.111.2.802.1.1.31.1.2.1.1.10
The operational value of the numerator of the
CycleTime parameter for the gate.
The numerator and denominator together represent the cycle
time as a rational number of seconds.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.111.2.802.1.1.31.1.2.1.1.11
The operational value of the denominator of the
CycleTime parameter for the gate.
The numerator and denominator together represent the
cycle time as a rational number of seconds.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.111.2.802.1.1.31.1.2.1.1.12
The administrative value of the CycleTimeExtension
parameter for the gate.
The value is an unsigned integer number of nanoseconds.

The value of this object MUST be retained across
reinitializations of t…
nanosecondsSNMPv2-SMIUnsigned32r/w
Type Constraints:
range: 0..4294967295
.1.3.111.2.802.1.1.31.1.2.1.1.13
The operational value of the CycleTimeExtension
parameter for the gate.
The value is an unsigned integer number of nanoseconds.
nanosecondsSNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.111.2.802.1.1.31.1.2.1.1.14
The administrative value of the BaseTime parameter for the gate.
The value is a representation of a PTPtime value,
consisting of a 48-bit integer
number of seconds and a 32-bit integer number of nanoseconds.
PTP timeIEEE8021-ST-MIBIEEE8021STPTPtimeValuer/w
Type Constraints:
range: 10
.1.3.111.2.802.1.1.31.1.2.1.1.15
The operationsl value of the BaseTime parameter for the gate.
The value is a representation of a PTPtime value,
consisting of a 48-bit integer
number of seconds and a 32-bit integer number of nanoseconds.
PTP timeIEEE8021-ST-MIBIEEE8021STPTPtimeValue
Type Constraints:
range: 10
.1.3.111.2.802.1.1.31.1.2.1.1.16
The ConfigChange parameter signals the start of a
configuration change for the gate
when it is set to TRUE. This should only be done
when the various administrative parameters
are all set to appropriate values.
SNMPv2-TCTruthValuer/w
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.111.2.802.1.1.31.1.2.1.1.17
The PTPtime at which the next config change is scheduled to occur.
The value is a representation of a PTPtime value,
consisting of a 48-bit integer
number of seconds and a 32-bit integer number of nanoseconds.
PTP timeIEEE8021-ST-MIBIEEE8021STPTPtimeValue
Type Constraints:
range: 10
.1.3.111.2.802.1.1.31.1.2.1.1.18
The granularity of the cycle time clock, represented as an
unsigned number of tenths of nanoseconds.

The value of this object MUST be retained across
reinitializations of the management system.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.111.2.802.1.1.31.1.2.1.1.19
The current time, in PTPtime, as maintained by the local system.
The value is a representation of a PTPtime value,
consisting of a 48-bit integer
number of seconds and a 32-bit integer number of nanoseconds.
IEEE8021-ST-MIBIEEE8021STPTPtimeValue
Type Constraints:
range: 10
.1.3.111.2.802.1.1.31.1.2.1.1.20
The value of the ConfigPending state machine variable.
The value is TRUE if a configuration change is in progress
but has not yet completed.
SNMPv2-TCTruthValue
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.111.2.802.1.1.31.1.2.1.1.21
A counter of the number of times that a re-configuration
of the traffic schedule has been requested with the old
schedule still running and the requested base time was
in the past.
SNMPv2-SMICounter64
Type Constraints:
range: 0..18446744073709551615
.1.3.111.2.802.1.1.31.1.2.1.1.23
The administrative value of the IPV parameter for the gate.
A value of -1 denotes the null value.
Integer32r/w
Constraints:
range: -1-2147483647
.1.3.111.2.802.1.1.31.1.2.1.1.24
The operational value of the IPV parameter for the gate.
A value of -1 denotes the null value.
Integer32r/w
Constraints:
range: -1-2147483647
.1.3.111.2.802.1.1.31.1.2.1.1.25
The PSFPGateClosedDueToInvalidRxEnable object contains
a Boolean value that indicates whether the
PSFPGateClosedDueToInvalidRx function is enabled (TRUE) or
disabled (FALSE).

The value of this object MUS…
SNMPv2-TCTruthValuer/w
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.111.2.802.1.1.31.1.2.1.1.26
The PSFPGateClosedDueToInvalidRx object contains
a Boolean value that indicates whether, if the
PSFPGateClosedDueToInvalidRx function is enabled,
all frames are to be discarded (TRUE) or not (FALSE).

The…
SNMPv2-TCTruthValuer/w
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.111.2.802.1.1.31.1.2.1.1.27
The PSFPGateClosedDueToOctetsExceededEnable object contains
a Boolean value that indicates whether the
PSFPGateClosedDueToOctetsExceeded function is enabled (TRUE)
or disabled (FALSE).

The value of this o…
SNMPv2-TCTruthValuer/w
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.111.2.802.1.1.31.1.2.1.1.28
The PSFPGateClosedDueToOctetsExceeded parameter contains
a Boolean value that indicates whether, if the
PSFPGateClosedDueToOctetsExceeded function is enabled, all
frames are to be discarded (TRUE) or not (FALSE).
SNMPv2-TCTruthValuer/w
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.111.2.802.1.1.31.1.2.1.1.29
The status of the row.

The writable columns in a row cannot be changed if the row
is active. All columns MUST have a valid value before a row
can be activated.
SNMPv2-TCRowStatusr/w
Type Values:
1active
2notInService
3notReady
4createAndGo
5createAndWait
6destroy
Description:
The RowStatus textual convention is used to manage the
creation and deletion of conceptual rows, and is used as the
value of the SYNTAX clause for the status column of a
conceptual row (as described in Section 7.7.1 of …
.1.3.111.2.802.1.1.31.1.2.1.1.30
.1.3.111.2.802.1.1.31.1.3.1 · 1 row entry · 11 columns
Uses the rfc variant from /opt/observium/mibs/rfc.
Command help
Walk ieee8021PSFPFlowMeterTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'IEEE8021-PSFP-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'IEEE8021-PSFP-MIB::ieee8021PSFPFlowMeterTable'
A table that contains the per-meter instance
manageable parameters for flow meters.
          
For a given Bridge component, a row in the table exists for
each flow meter instance.
          
All writable objects in this table must be
persistent over power up restart/reboot.
ieee8021PSFPFlowMeterEntry row .1.3.111.2.802.1.1.31.1.3.1.1
A list of objects that contains the manageable parameters for
flow meters for a Bridge component.
Column Syntax OID
The FlowMeterInstance parameter is an index into the
FlowMeterTable.

The value of this object MUST be retained across
reinitializations of the management system.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.111.2.802.1.1.31.1.3.1.1.1
The FlowMeterCIR parameter contains an integer value that
represents the CIR value for the flow meter, in bit/second.

The value of this object MUST be retained across
reinitializations of the management s…
SNMPv2-SMIUnsigned32r/w
Type Constraints:
range: 0..4294967295
.1.3.111.2.802.1.1.31.1.3.1.1.2
The FlowMeterCBS parameter contains an integer value that
represents the CBS value for the flow meter, in octets.

The value of this object MUST be retained across
reinitializations of the management syste…
SNMPv2-SMIUnsigned32r/w
Type Constraints:
range: 0..4294967295
.1.3.111.2.802.1.1.31.1.3.1.1.3
The FlowMeterEIR parameter contains an integer value that
represents the EIR value for the flow meter, in bit/second.

The value of this object MUST be retained across
reinitializations of the management s…
SNMPv2-SMIUnsigned32r/w
Type Constraints:
range: 0..4294967295
.1.3.111.2.802.1.1.31.1.3.1.1.4
The FlowMeterEBS parameter contains an integer value that
represents the EBS value for the flow meter, in octets.

The value of this object MUST be retained across
reinitializations of the management syste…
SNMPv2-SMIUnsigned32r/w
Type Constraints:
range: 0..4294967295
.1.3.111.2.802.1.1.31.1.3.1.1.5
The FlowMeterCF parameter contains an integer value that
represents the CF value for the flow meter, as an integer
value 0 or 1.

The value of this object MUST be retained across
reinitializations of the m…
Integer32r/w
Constraints:
range: 0-1
.1.3.111.2.802.1.1.31.1.3.1.1.6
The FlowMeterCM parameter contains an integer value that
represents the CM value for the flow meter, as an enumerated
value indicating colorBlind(1) or colorAware(2).

The value of this object MUST be reta…
Enumerationr/w
Enumerated Values:
1colorBlind
2colorAware
.1.3.111.2.802.1.1.31.1.3.1.1.7
The FlowMeterDropOnYellow parameter contains a Boolean value that
indicates whether yellow frames are dropped (TRUE) or
have drop_eligible set to TRUE (FALSE).

The value of this object MUST be retained ac…
SNMPv2-TCTruthValuer/w
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.111.2.802.1.1.31.1.3.1.1.8
The FlowMeterMarkAllFramesRedEnable parameter contains
a Boolean value that indicates whether the MarkAllFramesRed
function is enabled (TRUE) or disabled (FALSE).

The value of this object MUST be retained…
SNMPv2-TCTruthValuer/w
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.111.2.802.1.1.31.1.3.1.1.9
The FlowMeterMarkAllFramesRed parameter contains
a Boolean value that indicates whether, if the
MarkAllFramesRed function is enabled, all frames are to
be discarded (TRUE) or not (FALSE).

The value of th…
SNMPv2-TCTruthValuer/w
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.111.2.802.1.1.31.1.3.1.1.10
The status of the row.

The writable columns in a row cannot be changed if the row
is active. All columns MUST have a valid value before a row
can be activated.
SNMPv2-TCRowStatusr/w
Type Values:
1active
2notInService
3notReady
4createAndGo
5createAndWait
6destroy
Description:
The RowStatus textual convention is used to manage the
creation and deletion of conceptual rows, and is used as the
value of the SYNTAX clause for the status column of a
conceptual row (as described in Section 7.7.1 of …
.1.3.111.2.802.1.1.31.1.3.1.1.11
.1.3.111.2.802.1.1.31.1.4.1 · 1 row entry · 4 columns
Uses the rfc variant from /opt/observium/mibs/rfc.
Command help
Walk ieee8021PSFPStreamParameterTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'IEEE8021-PSFP-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'IEEE8021-PSFP-MIB::ieee8021PSFPStreamParameterTable'
A table that contains per-Bridge component
manageable parameters for PSFP.
          
A row in the table exists for each Bridge component.
          
All writable objects in this table must be
persistent over power up restart/reboot.
ieee8021PSFPStreamParameterEntry row .1.3.111.2.802.1.1.31.1.4.1.1
A list of objects that contains the manageable parameters for
flow meters for a Bridge component.
Column Syntax OID
The MaxStreamFilterInstances parameter defines the
maximum number of stream filter instances that are
supported by this Bridge component.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.111.2.802.1.1.31.1.4.1.1.1
The MaxStreamGateInstances parameter defines the
maximum number of stream gate instances that are
supported by this Bridge component.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.111.2.802.1.1.31.1.4.1.1.2
The MaxFlowMeterInstances parameter defines the
maximum number of flow meter instances that are
supported by this Bridge component.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.111.2.802.1.1.31.1.4.1.1.3
The SupportedListMax parameter defines the
The maximum value supported by this Bridge component of
the AdminControlListLength and
OperControlListLength parameters.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.111.2.802.1.1.31.1.4.1.1.4