.1.3.111.2.802.1.1.31.1.1.1
·
1 row entry
·
14 columns
Uses the rfc variant from
Command help
/opt/observium/mibs/rfc.
Walk ieee8021PSFPStreamFilterTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'IEEE8021-PSFP-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'IEEE8021-PSFP-MIB::ieee8021PSFPStreamFilterTable'
A table that contains the per-filter instance
manageable parameters for stream filters.
A row in the table exists for each stream filter instance.
associated with a Bridge component.
All writable objects in this table must be
persistent over power up restart/reboot.
A list of objects that contains the manageable parameters for
stream filters for a Bridge component.
stream filters for a Bridge component.
| Column | Syntax | OID | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
The StreamFilterInstance parameter is an index into the
StreamFilterTable. The value of this object MUST be retained across reinitializations of the management system. |
SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.111.2.802.1.1.31.1.1.1.1.1 |
||||||||||||
|
The StreamHandleSpec parameter contains a stream identifier
specification value. A value of -1 denotes the wild card value; all positive values denote stream identifier values. The value of this object M… |
Integer32r/w Constraints: range: -1-2147483647 |
.1.3.111.2.802.1.1.31.1.1.1.1.2 |
||||||||||||
|
The PrioritySpec parameter contains a priority
specification value. A value of -1 denotes the wild card value; zero or positive values denote priority values. The value of this object MUST be retained ac… |
Integer32r/w Constraints: range: -1-2147483647 |
.1.3.111.2.802.1.1.31.1.1.1.1.3 |
||||||||||||
|
The StreamGateInstance parameter contains the index of an
entry in the Stream Gate Table. The value of this object MUST be retained across reinitializations of the management system. |
SNMPv2-SMIUnsigned32r/w Type Constraints: range: 0..4294967295 |
.1.3.111.2.802.1.1.31.1.1.1.1.4 |
||||||||||||
|
The FilterSpecificationList parameter contains a list of
filter specifications associated with this stream filter. The octet string value represents the contents of the list as an ordered list of entrie… |
OctetStringr/w | .1.3.111.2.802.1.1.31.1.1.1.1.5 |
||||||||||||
|
The MatchingFramesCount counter counts received frames that
match this stream filter. |
SNMPv2-SMICounter64 Type Constraints: range: 0..18446744073709551615 |
.1.3.111.2.802.1.1.31.1.1.1.1.6 |
||||||||||||
|
The PassingFramesCount counter counts received frames that
pass the gate associated with this stream filter. |
SNMPv2-SMICounter64 Type Constraints: range: 0..18446744073709551615 |
.1.3.111.2.802.1.1.31.1.1.1.1.7 |
||||||||||||
|
The NotPassingFramesCount counter counts received frames that
do not pass the gate associated with this stream filter. |
SNMPv2-SMICounter64 Type Constraints: range: 0..18446744073709551615 |
.1.3.111.2.802.1.1.31.1.1.1.1.8 |
||||||||||||
|
The PassingSDUCount counter counts received frames that
pass the SDU size filter specification associated with this stream filter. |
SNMPv2-SMICounter64 Type Constraints: range: 0..18446744073709551615 |
.1.3.111.2.802.1.1.31.1.1.1.1.9 |
||||||||||||
|
The NotPassingSDUCount counter counts received frames that
do not pass the SDU size filter specification associated with this stream filter. |
SNMPv2-SMICounter64 Type Constraints: range: 0..18446744073709551615 |
.1.3.111.2.802.1.1.31.1.1.1.1.10 |
||||||||||||
|
The REDFramesCount counter counts received
frames that were discarded as a result of the operation of the flow meter. |
SNMPv2-SMICounter64 Type Constraints: range: 0..18446744073709551615 |
.1.3.111.2.802.1.1.31.1.1.1.1.11 |
||||||||||||
|
The ieee8021PSFPStreamBlockedDueToOversizeFrameEnable object
contains a Boolean value that indicates whether the ieee8021PSFPStreamBlockedDueToOversizeFrame function is enabled (TRUE) or disabled (FALSE). … |
SNMPv2-TCTruthValuer/w Type Values:
Description: Represents a boolean value. |
.1.3.111.2.802.1.1.31.1.1.1.1.12 |
||||||||||||
|
The ieee8021PSFPStreamBlockedDueToOversizeFrame object
contains a Boolean value that indicates whether, if the ieee8021PSFPStreamBlockedDueToOversizeFrame function is enabled, all frames are to be discarded (TRUE) or… |
SNMPv2-TCTruthValuer/w Type Values:
Description: Represents a boolean value. |
.1.3.111.2.802.1.1.31.1.1.1.1.13 |
||||||||||||
|
The status of the row.
The writable columns in a row cannot be changed if the row is active. All columns MUST have a valid value before a row can be activated. |
SNMPv2-TCRowStatusr/w Type Values:
Description: The RowStatus textual convention is used to manage the creation and deletion of conceptual rows, and is used as the value of the SYNTAX clause for the status column of a conceptual row (as described in Section 7.7.1 of … |
.1.3.111.2.802.1.1.31.1.1.1.1.14 |
.1.3.111.2.802.1.1.31.1.2.1
·
1 row entry
·
29 columns
Uses the rfc variant from
Command help
/opt/observium/mibs/rfc.
Walk ieee8021PSFPStreamGateTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'IEEE8021-PSFP-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'IEEE8021-PSFP-MIB::ieee8021PSFPStreamGateTable'
A table that contains the per-gate instance
manageable parameters for stream gate scheduling.
For a given Bridge component, a row in the table exists for
each stream gate instance.
All writable objects in this table must be
persistent over power up restart/reboot.
A list of objects that contains the manageable parameters for
stream gate scheduling for a Bridge component.
stream gate scheduling for a Bridge component.
| Column | Syntax | OID | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
The StreamGateInstance parameter is an index into the
StreamGateTable. The value of this object MUST be retained across reinitializations of the management system. |
SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.111.2.802.1.1.31.1.2.1.1.1 |
||||||||||||
|
The GateEnabled parameter determines whether the stream gate
is active (true) or inactive (false). The value of this object MUST be retained across reinitializations of the management system. |
SNMPv2-TCTruthValuer/w Type Values:
Description: Represents a boolean value. |
.1.3.111.2.802.1.1.31.1.2.1.1.2 |
||||||||||||
|
The administrative value of the GateStates parameter for the
stream gate. The open value indicates that the gate is open, the closed value indicates that the gate is closed. The value of this object MUST… |
Enumerationr/w Enumerated Values:
|
.1.3.111.2.802.1.1.31.1.2.1.1.3 |
||||||||||||
|
The operational value of the GateStates parameter for the
stream gate. The open value indicates that the gate is open, the closed value indicates that the gate is closed. |
Enumeration Enumerated Values:
|
.1.3.111.2.802.1.1.31.1.2.1.1.4 |
||||||||||||
|
The administrative value of the ListMax parameter for the gate.
The integer value indicates the number of entries (TLVs) in the AdminControlList. The value of this object MUST be retained across reinitial… |
SNMPv2-SMIUnsigned32r/w Type Constraints: range: 0..4294967295 |
.1.3.111.2.802.1.1.31.1.2.1.1.5 |
||||||||||||
|
The operational value of the ListMax parameter for the gate.
The integer value indicates the number of entries (TLVs) in the OperControlList. |
SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.111.2.802.1.1.31.1.2.1.1.6 |
||||||||||||
|
The administrative value of the ControlList parameter for the gate.
The octet string value represents the contents of the control list as an ordered list of entries, each encoded as a TLV, as follows. The first octet o… |
OctetStringr/w | .1.3.111.2.802.1.1.31.1.2.1.1.7 |
||||||||||||
|
The operational value of the ControlList parameter for the gate.
The octet string value represents the contents of the control list as an ordered list of entries, each encoded as a TLV, as follows. The first octet of e… |
OctetString | .1.3.111.2.802.1.1.31.1.2.1.1.8 |
||||||||||||
|
The administrative value of the numerator of the CycleTime
parameter for the gate. The numerator and denominator together represent the cycle time as a rational number of seconds. The value of this object… |
SNMPv2-SMIUnsigned32r/w Type Constraints: range: 0..4294967295 |
.1.3.111.2.802.1.1.31.1.2.1.1.9 |
||||||||||||
|
The administrative value of the denominator of the
CycleTime parameter for the gate. The numerator and denominator together represent the cycle time as a rational number of seconds. The value of this obj… |
SNMPv2-SMIUnsigned32r/w Type Constraints: range: 0..4294967295 |
.1.3.111.2.802.1.1.31.1.2.1.1.10 |
||||||||||||
|
The operational value of the numerator of the
CycleTime parameter for the gate. The numerator and denominator together represent the cycle time as a rational number of seconds. |
SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.111.2.802.1.1.31.1.2.1.1.11 |
||||||||||||
|
The operational value of the denominator of the
CycleTime parameter for the gate. The numerator and denominator together represent the cycle time as a rational number of seconds. |
SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.111.2.802.1.1.31.1.2.1.1.12 |
||||||||||||
|
The administrative value of the CycleTimeExtension
parameter for the gate. The value is an unsigned integer number of nanoseconds. The value of this object MUST be retained across reinitializations of t… |
nanosecondsSNMPv2-SMIUnsigned32r/w Type Constraints: range: 0..4294967295 |
.1.3.111.2.802.1.1.31.1.2.1.1.13 |
||||||||||||
|
The operational value of the CycleTimeExtension
parameter for the gate. The value is an unsigned integer number of nanoseconds. |
nanosecondsSNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.111.2.802.1.1.31.1.2.1.1.14 |
||||||||||||
|
The administrative value of the BaseTime parameter for the gate.
The value is a representation of a PTPtime value, consisting of a 48-bit integer number of seconds and a 32-bit integer number of nanoseconds. … |
PTP timeIEEE8021-ST-MIBIEEE8021STPTPtimeValuer/w Type Constraints: range: 10 |
.1.3.111.2.802.1.1.31.1.2.1.1.15 |
||||||||||||
|
The operationsl value of the BaseTime parameter for the gate.
The value is a representation of a PTPtime value, consisting of a 48-bit integer number of seconds and a 32-bit integer number of nanoseconds. |
PTP timeIEEE8021-ST-MIBIEEE8021STPTPtimeValue Type Constraints: range: 10 |
.1.3.111.2.802.1.1.31.1.2.1.1.16 |
||||||||||||
|
The ConfigChange parameter signals the start of a
configuration change for the gate when it is set to TRUE. This should only be done when the various administrative parameters are all set to appropriate values. |
SNMPv2-TCTruthValuer/w Type Values:
Description: Represents a boolean value. |
.1.3.111.2.802.1.1.31.1.2.1.1.17 |
||||||||||||
|
The PTPtime at which the next config change is scheduled to occur.
The value is a representation of a PTPtime value, consisting of a 48-bit integer number of seconds and a 32-bit integer number of nanoseconds. … |
PTP timeIEEE8021-ST-MIBIEEE8021STPTPtimeValue Type Constraints: range: 10 |
.1.3.111.2.802.1.1.31.1.2.1.1.18 |
||||||||||||
|
The granularity of the cycle time clock, represented as an
unsigned number of tenths of nanoseconds. The value of this object MUST be retained across reinitializations of the management system. |
SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.111.2.802.1.1.31.1.2.1.1.19 |
||||||||||||
|
The current time, in PTPtime, as maintained by the local system.
The value is a representation of a PTPtime value, consisting of a 48-bit integer number of seconds and a 32-bit integer number of nanoseconds. |
IEEE8021-ST-MIBIEEE8021STPTPtimeValue Type Constraints: range: 10 |
.1.3.111.2.802.1.1.31.1.2.1.1.20 |
||||||||||||
|
The value of the ConfigPending state machine variable.
The value is TRUE if a configuration change is in progress but has not yet completed. |
SNMPv2-TCTruthValue Type Values:
Description: Represents a boolean value. |
.1.3.111.2.802.1.1.31.1.2.1.1.21 |
||||||||||||
|
A counter of the number of times that a re-configuration
of the traffic schedule has been requested with the old schedule still running and the requested base time was in the past. |
SNMPv2-SMICounter64 Type Constraints: range: 0..18446744073709551615 |
.1.3.111.2.802.1.1.31.1.2.1.1.23 |
||||||||||||
|
The administrative value of the IPV parameter for the gate.
A value of -1 denotes the null value. |
Integer32r/w Constraints: range: -1-2147483647 |
.1.3.111.2.802.1.1.31.1.2.1.1.24 |
||||||||||||
|
The operational value of the IPV parameter for the gate.
A value of -1 denotes the null value. |
Integer32r/w Constraints: range: -1-2147483647 |
.1.3.111.2.802.1.1.31.1.2.1.1.25 |
||||||||||||
|
The PSFPGateClosedDueToInvalidRxEnable object contains
a Boolean value that indicates whether the PSFPGateClosedDueToInvalidRx function is enabled (TRUE) or disabled (FALSE). The value of this object MUS… |
SNMPv2-TCTruthValuer/w Type Values:
Description: Represents a boolean value. |
.1.3.111.2.802.1.1.31.1.2.1.1.26 |
||||||||||||
|
The PSFPGateClosedDueToInvalidRx object contains
a Boolean value that indicates whether, if the PSFPGateClosedDueToInvalidRx function is enabled, all frames are to be discarded (TRUE) or not (FALSE). The… |
SNMPv2-TCTruthValuer/w Type Values:
Description: Represents a boolean value. |
.1.3.111.2.802.1.1.31.1.2.1.1.27 |
||||||||||||
|
The PSFPGateClosedDueToOctetsExceededEnable object contains
a Boolean value that indicates whether the PSFPGateClosedDueToOctetsExceeded function is enabled (TRUE) or disabled (FALSE). The value of this o… |
SNMPv2-TCTruthValuer/w Type Values:
Description: Represents a boolean value. |
.1.3.111.2.802.1.1.31.1.2.1.1.28 |
||||||||||||
|
The PSFPGateClosedDueToOctetsExceeded parameter contains
a Boolean value that indicates whether, if the PSFPGateClosedDueToOctetsExceeded function is enabled, all frames are to be discarded (TRUE) or not (FALSE). … |
SNMPv2-TCTruthValuer/w Type Values:
Description: Represents a boolean value. |
.1.3.111.2.802.1.1.31.1.2.1.1.29 |
||||||||||||
|
The status of the row.
The writable columns in a row cannot be changed if the row is active. All columns MUST have a valid value before a row can be activated. |
SNMPv2-TCRowStatusr/w Type Values:
Description: The RowStatus textual convention is used to manage the creation and deletion of conceptual rows, and is used as the value of the SYNTAX clause for the status column of a conceptual row (as described in Section 7.7.1 of … |
.1.3.111.2.802.1.1.31.1.2.1.1.30 |
.1.3.111.2.802.1.1.31.1.3.1
·
1 row entry
·
11 columns
Uses the rfc variant from
Command help
/opt/observium/mibs/rfc.
Walk ieee8021PSFPFlowMeterTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'IEEE8021-PSFP-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'IEEE8021-PSFP-MIB::ieee8021PSFPFlowMeterTable'
A table that contains the per-meter instance
manageable parameters for flow meters.
For a given Bridge component, a row in the table exists for
each flow meter instance.
All writable objects in this table must be
persistent over power up restart/reboot.
A list of objects that contains the manageable parameters for
flow meters for a Bridge component.
flow meters for a Bridge component.
| Column | Syntax | OID | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
The FlowMeterInstance parameter is an index into the
FlowMeterTable. The value of this object MUST be retained across reinitializations of the management system. |
SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.111.2.802.1.1.31.1.3.1.1.1 |
||||||||||||
|
The FlowMeterCIR parameter contains an integer value that
represents the CIR value for the flow meter, in bit/second. The value of this object MUST be retained across reinitializations of the management s… |
SNMPv2-SMIUnsigned32r/w Type Constraints: range: 0..4294967295 |
.1.3.111.2.802.1.1.31.1.3.1.1.2 |
||||||||||||
|
The FlowMeterCBS parameter contains an integer value that
represents the CBS value for the flow meter, in octets. The value of this object MUST be retained across reinitializations of the management syste… |
SNMPv2-SMIUnsigned32r/w Type Constraints: range: 0..4294967295 |
.1.3.111.2.802.1.1.31.1.3.1.1.3 |
||||||||||||
|
The FlowMeterEIR parameter contains an integer value that
represents the EIR value for the flow meter, in bit/second. The value of this object MUST be retained across reinitializations of the management s… |
SNMPv2-SMIUnsigned32r/w Type Constraints: range: 0..4294967295 |
.1.3.111.2.802.1.1.31.1.3.1.1.4 |
||||||||||||
|
The FlowMeterEBS parameter contains an integer value that
represents the EBS value for the flow meter, in octets. The value of this object MUST be retained across reinitializations of the management syste… |
SNMPv2-SMIUnsigned32r/w Type Constraints: range: 0..4294967295 |
.1.3.111.2.802.1.1.31.1.3.1.1.5 |
||||||||||||
|
The FlowMeterCF parameter contains an integer value that
represents the CF value for the flow meter, as an integer value 0 or 1. The value of this object MUST be retained across reinitializations of the m… |
Integer32r/w Constraints: range: 0-1 |
.1.3.111.2.802.1.1.31.1.3.1.1.6 |
||||||||||||
|
The FlowMeterCM parameter contains an integer value that
represents the CM value for the flow meter, as an enumerated value indicating colorBlind(1) or colorAware(2). The value of this object MUST be reta… |
Enumerationr/w Enumerated Values:
|
.1.3.111.2.802.1.1.31.1.3.1.1.7 |
||||||||||||
|
The FlowMeterDropOnYellow parameter contains a Boolean value that
indicates whether yellow frames are dropped (TRUE) or have drop_eligible set to TRUE (FALSE). The value of this object MUST be retained ac… |
SNMPv2-TCTruthValuer/w Type Values:
Description: Represents a boolean value. |
.1.3.111.2.802.1.1.31.1.3.1.1.8 |
||||||||||||
|
The FlowMeterMarkAllFramesRedEnable parameter contains
a Boolean value that indicates whether the MarkAllFramesRed function is enabled (TRUE) or disabled (FALSE). The value of this object MUST be retained… |
SNMPv2-TCTruthValuer/w Type Values:
Description: Represents a boolean value. |
.1.3.111.2.802.1.1.31.1.3.1.1.9 |
||||||||||||
|
The FlowMeterMarkAllFramesRed parameter contains
a Boolean value that indicates whether, if the MarkAllFramesRed function is enabled, all frames are to be discarded (TRUE) or not (FALSE). The value of th… |
SNMPv2-TCTruthValuer/w Type Values:
Description: Represents a boolean value. |
.1.3.111.2.802.1.1.31.1.3.1.1.10 |
||||||||||||
|
The status of the row.
The writable columns in a row cannot be changed if the row is active. All columns MUST have a valid value before a row can be activated. |
SNMPv2-TCRowStatusr/w Type Values:
Description: The RowStatus textual convention is used to manage the creation and deletion of conceptual rows, and is used as the value of the SYNTAX clause for the status column of a conceptual row (as described in Section 7.7.1 of … |
.1.3.111.2.802.1.1.31.1.3.1.1.11 |
.1.3.111.2.802.1.1.31.1.4.1
·
1 row entry
·
4 columns
Uses the rfc variant from
Command help
/opt/observium/mibs/rfc.
Walk ieee8021PSFPStreamParameterTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'IEEE8021-PSFP-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'IEEE8021-PSFP-MIB::ieee8021PSFPStreamParameterTable'
A table that contains per-Bridge component
manageable parameters for PSFP.
A row in the table exists for each Bridge component.
All writable objects in this table must be
persistent over power up restart/reboot.
A list of objects that contains the manageable parameters for
flow meters for a Bridge component.
flow meters for a Bridge component.
| Column | Syntax | OID |
|---|---|---|
|
The MaxStreamFilterInstances parameter defines the
maximum number of stream filter instances that are supported by this Bridge component. |
SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.111.2.802.1.1.31.1.4.1.1.1 |
|
The MaxStreamGateInstances parameter defines the
maximum number of stream gate instances that are supported by this Bridge component. |
SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.111.2.802.1.1.31.1.4.1.1.2 |
|
The MaxFlowMeterInstances parameter defines the
maximum number of flow meter instances that are supported by this Bridge component. |
SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.111.2.802.1.1.31.1.4.1.1.3 |
|
The SupportedListMax parameter defines the
The maximum value supported by this Bridge component of the AdminControlListLength and OperControlListLength parameters. |
SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.111.2.802.1.1.31.1.4.1.1.4 |