hwVOPGfastSNRMarginConfProfMinSnrmRmcUs
HUAWEI-VOP-MIB ·
.1.3.6.1.4.1.2011.6.144.1.1.14.1.43
Object
column
r/w
0.1 dB Unsigned32
Defines the upstream minimum noise margin the FTU-O receiver tolerates for the RMC. If the downstream RMC noise margin falls below this level, the FTU-O initiates the RPA procedure. The minimum noise margin ranges from 0 to 310 units of 0.1 dB (Physical values are 0 to 31 dB). A value of 0 means that there is no minimum. Unit: 0.1 dB.
Context
- MIB
- HUAWEI-VOP-MIB
- OID
.1.3.6.1.4.1.2011.6.144.1.1.14.1.43- Type
- column
- Access
- readwrite
- Status
- current
- Units
- 0.1 dB
- Parent
- hwVOPSNRMarginConfProfEntry
Syntax
0.1 dB Unsigned32
Values & Constraints
Object Constraints
range: 0-310