hwVOPGfastSNRMarginConfProfDsTimeUs
HUAWEI-VOP-MIB ·
.1.3.6.1.4.1.2011.6.144.1.1.14.1.39
Object
column
r/w
seconds Unsigned32
The Upstream Down-Shift Time Interval, to be used when hwVOPGfastSNRMarginConfProfRaModeUs is set to dynamicRa. The interval of time the upstream noise margin should stay below the Upstream Down-Shift Noise Margin before the xTU-C shall attempt to decrease the upstream net data rate. The time interval ranges from 0 to 16383 seconds. Unit: seconds.
Context
- MIB
- HUAWEI-VOP-MIB
- OID
.1.3.6.1.4.1.2011.6.144.1.1.14.1.39- Type
- column
- Access
- readwrite
- Status
- current
- Units
- seconds
- Parent
- hwVOPSNRMarginConfProfEntry
Syntax
seconds Unsigned32
Values & Constraints
Object Constraints
range: 0-16383