hwVoAnaloglfConfigPortImpedance
HUAWEI-VO-ANALOG-IF-MIB ·
.1.3.6.1.4.1.2011.5.25.1.3.1.1.1.3
Object
column
Enumeration
This object expresses the port impedance of voice analog interfaces.
impedance600Real : 600 Ohms
This impedance is primarily used by FXS.
impedanceComplex : 200 Ohms + 680 Ohms || 100nF
This impedance is primarily used by FX0 and E&M.
Context
- MIB
- HUAWEI-VO-ANALOG-IF-MIB
- OID
.1.3.6.1.4.1.2011.5.25.1.3.1.1.1.3- Type
- column
- Access
- readonly
- Status
- current
- Parent
- hwVoAnalogIfCommonConfigEntry
- Table
- hwVoAnalogIfCommonConfigTable
- Siblings
- 5
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | impedance600Real |
2 | impedanceComplex |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| hwVoAnalogIfConfigPortNumber Index of voice analog interface common config table. It identify the
number of the voice port. | column | Integer32 | .1.3.6.1.4.1.2011.5.25.1.3.1.1.1.1 |
| hwVoAnalogIfConfigPortType This object expresses the type of the voice analog interfaces.
fxs : the type of the voice port is FXS.
fxo : the type of the voice port is FXO.
em : the type of the voice port i… | column | Enumeration | .1.3.6.1.4.1.2011.5.25.1.3.1.1.1.2 |
| hwVoAnalogIfConfigInitialDigitTimeOut This object states the longgest time to wait the first input digit from
caller side. The default value is 10 seconds. | column | Integer32 | .1.3.6.1.4.1.2011.5.25.1.3.1.1.1.4 |
| hwVoAnalogIfConfigInterDigitTimeOut This object states the longest time to wait between two input digit from
caller side. The default value is 10 seconds. | column | Integer32 | .1.3.6.1.4.1.2011.5.25.1.3.1.1.1.5 |
| hwVoAnalogIfConfigCallDisconnect This object states the time the system waits for the caller side to hang up
after the connect is disable. The default value is 10 seconds. | column | Integer32 | .1.3.6.1.4.1.2011.5.25.1.3.1.1.1.6 |