HUAWEI-VO-ANALOG-IF-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
7
Rows
7
Columns
36
.1.3.6.1.4.1.2011.5.25.1.3.1.1
·
1 row entry
·
6 columns
The voice analog interface common configuration table contains information about configuration parameters for analog voice interface.
An entry in the voice analog interface common configuration table.
The entry is automatically created when a analog voice interface hardware is found.
The entry is automatically created when a analog voice interface hardware is found.
Indexes
hwVoAnalogIfConfigPortNumber
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
hwVoAnalogIfConfigPortNumber
Index of voice analog interface common config table. It identify the
number of the voice port. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.2011.5.25.1.3.1.1.1.1 |
||||||
|
hwVoAnalogIfConfigPortType
This object expresses the type of the voice analog interfaces.
fxs : the type of the voice port is FXS. fxo : the type of the voice port is FXO. em : the type of the voice port is E&M. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2011.5.25.1.3.1.1.1.2 |
||||||
|
hwVoAnaloglfConfigPortImpedance
This object expresses the port impedance of voice analog interfaces.
impedance600Real : 600 Ohms This impedance is primarily used by FXS. impedanceComplex : 200 Ohms + 680 Ohms || 1… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2011.5.25.1.3.1.1.1.3 |
||||||
|
hwVoAnalogIfConfigInitialDigitTimeOut
This object states the longgest time to wait the first input digit from
caller side. The default value is 10 seconds. |
Integer32r/w Constraints: range: 0-300 |
.1.3.6.1.4.1.2011.5.25.1.3.1.1.1.4 |
||||||
|
hwVoAnalogIfConfigInterDigitTimeOut
This object states the longest time to wait between two input digit from
caller side. The default value is 10 seconds. |
Integer32r/w Constraints: range: 0-300 |
.1.3.6.1.4.1.2011.5.25.1.3.1.1.1.5 |
||||||
|
hwVoAnalogIfConfigCallDisconnect
This object states the time the system waits for the caller side to hang up
after the connect is disable. The default value is 10 seconds. |
Integer32 Constraints: range: 0-120 |
.1.3.6.1.4.1.2011.5.25.1.3.1.1.1.6 |
.1.3.6.1.4.1.2011.5.25.1.3.2.1
·
1 row entry
·
2 columns
The voice analog interface fxs configuration table contains information about configuration parameters for analog fxs voice interface.
An entry in the voice analog interface fxs configuration table.
The entry is automatically created when a analog fxs voice interface hardware is found.
The entry is automatically created when a analog fxs voice interface hardware is found.
Indexes
hwVoAnalogIfFXSConfigPortNumber
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
hwVoAnalogIfFXSConfigPortNumber
Index of voice analog interface fxs config table. It identify the
number of the fxs voice port. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.2011.5.25.1.3.2.1.1.1 |
||||
|
hwVoAnalogIfFXSConfigStartMode
This object expresses the signaling type of analog fxs interface.
The default value is loopStart. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2011.5.25.1.3.2.1.1.2 |
.1.3.6.1.4.1.2011.5.25.1.3.2.3
·
1 row entry
·
3 columns
The voice analog interface fxs timer table contains information about timer parameters for analog fxs voice interface.
An entry in the voice analog interface fxs configuration table.
The entry is automatically created when a analog fxs voice interface hardware is found.
The entry is automatically created when a analog fxs voice interface hardware is found.
Indexes
hwVoAnalogIfFXSTimerPortNumber
| Column | Syntax | OID |
|---|---|---|
|
hwVoAnalogIfFXSTimerPortNumber
Index of voice analog interface fxs timer table. It identify the
number of the fxs voice port. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.2011.5.25.1.3.2.3.1.1 |
|
hwVoAnalogIfFXSTimerDtmf
This object expresses outgoing dtmf digit duration of the analog
fxs interface. The default value is 120 milliseconds |
Integer32 Constraints: range: 50-500 |
.1.3.6.1.4.1.2011.5.25.1.3.2.3.1.2 |
|
hwVoAnalogIfFXSTimerDtmfInterval
This object expresses outgoing dtmf interval duration of the analog
fxs interface. The default value is 120 milliseconds |
Integer32 Constraints: range: 50-500 |
.1.3.6.1.4.1.2011.5.25.1.3.2.3.1.3 |
.1.3.6.1.4.1.2011.5.25.1.3.3.1
·
1 row entry
·
6 columns
The voice analog interface fxo configuration table contains information about configuration parameters for analog fxo voice interface.
An entry in the voice analog interface fxo configuration table.
The entry is automatically created when a analog fxo voice interface hardware is found.
The entry is automatically created when a analog fxo voice interface hardware is found.
Indexes
hwVoAnalogIfFXOConfigPortNumber
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
hwVoAnalogIfFXOConfigPortNumber
Index of voice analog interface fxo config table. It identify the
number of the fxo voice port. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.2011.5.25.1.3.3.1.1.1 |
||||||||
|
hwVoAnalogIfFXOConfigStartMode
This object expresses the signal type of analog fxo interface.
The default value is fxoLoopStart. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2011.5.25.1.3.3.1.1.2 |
||||||||
|
hwVoAnalogIfFXOConfigAlertNumber
This object expresses the number of rings detected before loop
being closed. The default value is 2. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.2011.5.25.1.3.3.1.1.3 |
||||||||
|
hwVoAnalogIfFXOConfigArea
This object expresses the busy tone of analog fxo interface.
The default value is europe. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.2011.5.25.1.3.3.1.1.4 |
||||||||
|
hwVoAnalogIfFXOPreDialDelay
This object expresses the pre-dial delay of analog fxo interface.
The default value is 1 seconds. |
Integer32r/w Constraints: range: 0-10 |
.1.3.6.1.4.1.2011.5.25.1.3.3.1.1.5 |
||||||||
|
hwVoAnaloglfFXOConfigPortImpedance
This object expresses the port impedance of FXO interfaces.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.2011.5.25.1.3.3.1.1.6 |
.1.3.6.1.4.1.2011.5.25.1.3.3.3
·
1 row entry
·
3 columns
The voice analog interface fxo timer table contains information about timer parameters for analog fxo voice interface.
An entry in the voice analog interface fxo timer table.
The entry is automatically created when a analog fxo voice interface hardware is found.
The entry is automatically created when a analog fxo voice interface hardware is found.
Indexes
hwVoAnalogIfFXOTimerPortNumber
| Column | Syntax | OID |
|---|---|---|
|
hwVoAnalogIfFXOTimerPortNumber
Index of voice analog interface fxo timer table. It identify the
number of the fxo voice port. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.2011.5.25.1.3.3.3.1.1 |
|
hwVoAnalogIfFXOTimerDtmf
This object expresses outgoing dtmf digit duration of the analog
fxo interface. The default value is 120 milliseconds |
Integer32r/w Constraints: range: 50-500 |
.1.3.6.1.4.1.2011.5.25.1.3.3.3.1.2 |
|
hwVoAnalogIfFXOTimerDtmfInterval
This object expresses outgoing dtmf interval duration of the analog
fxo interface. The default value is 120 milliseconds |
Integer32r/w Constraints: range: 50-500 |
.1.3.6.1.4.1.2011.5.25.1.3.3.3.1.3 |
.1.3.6.1.4.1.2011.5.25.1.3.4.1
·
1 row entry
·
6 columns
The voice analog interface e&m configuration table contains information about configuration parameters for analog e&m voice interface.
An entry in the voice analog interface e&m configuration table.
The entry is automatically created when a analog e&m voice interface hardware is found.
The entry is automatically created when a analog e&m voice interface hardware is found.
Indexes
hwVoAnalogIfEMConfigPortNumber
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
hwVoAnalogIfEMConfigPortNumber
Index of voice analog interface e&m config table. It identify the
number of the e&m voice port. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.2011.5.25.1.3.4.1.1.1 |
||||||||
|
hwVoAnalogIfEMConfigSignalMode
This object expresses the signal mode of the analog e&m interfaces.
The default value is immediateDial. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.2011.5.25.1.3.4.1.1.2 |
||||||||
|
hwVoAnalogIfEMConfigPhyParm
This object expresses the operation of the analog e&m signal.
The default value of this object is fourWiresOperation. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.2011.5.25.1.3.4.1.1.3 |
||||||||
|
hwVoAnalogIfEMConfigPhyType
This object expresses the e&m lead signaling type of the analog e&m interface.
The default is type5. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.2011.5.25.1.3.4.1.1.4 |
||||||||
|
hwVoAnalogIfEMConfigTimeoutRinging
This object expresses the ring timeout of the analog e&m interface.
The value of 65535 indicates the timer is approach infinity. The default value of this object is 60 seconds. |
Integer32r/w Constraints: range: 65535-65535range: 5-600 |
.1.3.6.1.4.1.2011.5.25.1.3.4.1.1.5 |
||||||||
|
hwVoAnalogIfEMConfigTimeoutWaitDigit
This object expresses the wait digit timeout of the analog e&m interface.
The value of 65535 indicates the timer is approach infinity. The default value of this object is 5 seconds. |
Integer32r/w Constraints: range: 3-600range: 65535-65535 |
.1.3.6.1.4.1.2011.5.25.1.3.4.1.1.6 |
hwVoAnalogIfEMTimerTable
table.1.3.6.1.4.1.2011.5.25.1.3.4.3
·
1 row entry
·
10 columns
The voice analog interface e&m timer table contains information about timer parameters for analog e&m voice interface.
An entry in the voice analog interface e&m timer table.
The entry is automatically created when a analog e&m voice interface hardware is found.
The entry is automatically created when a analog e&m voice interface hardware is found.
Indexes
hwVoAnalogIfEMTimerPortNumber
| Column | Syntax | OID |
|---|---|---|
|
hwVoAnalogIfEMTimerPortNumber
Index of voice analog interface e&m timer table. It identify the
number of the e&m voice port. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.2011.5.25.1.3.4.3.1.1 |
|
hwVoAnalogIfEMTimerDtmf
This object expresses outgoing dtmf digit duration of the analog
e&m interface. The default value is 120 milliseconds |
Integer32r/w Constraints: range: 50-500 |
.1.3.6.1.4.1.2011.5.25.1.3.4.3.1.2 |
|
hwVoAnalogIfEMTimerDtmfInterval
This object expresses outgoing dtmf interval duration of the analog
e&m interface. The default value is 120 milliseconds |
Integer32r/w Constraints: range: 50-500 |
.1.3.6.1.4.1.2011.5.25.1.3.4.3.1.3 |
|
hwVoAnalogIfEMTimerCallInterval
This object expresses the dureation of call clearing. The default value
is 200 milliseconds. |
Integer32r/w Constraints: range: 200-2000 |
.1.3.6.1.4.1.2011.5.25.1.3.4.3.1.4 |
|
hwVoAnalogIfEMTimerSendWink
This object expresses the max time between receiving seizure signal
and sending wink signal. This object can olny be used when hwVoAnalogIfEMConfigSignalMode is 'winkStart'. The default value is 500 milliseconds. |
Integer32r/w Constraints: range: 100-5000 |
.1.3.6.1.4.1.2011.5.25.1.3.4.3.1.5 |
|
hwVoAnalogIfEMTimerWinkRising
This object expresses the max time between sending seizure signal and
receiving wink signal. This object can only be used when hwVoAnalogIfEMConfigSignalMode is 'winkStart'. The default value is 2000 milliseconds. |
Integer32r/w Constraints: range: 100-5000 |
.1.3.6.1.4.1.2011.5.25.1.3.4.3.1.6 |
|
hwVoAnalogIfEMTimerWinkHold
This object expresses the max duration for sending wink signal. This
object can only be used when hwVoAnalogIfEMConfigSignalMode is 'winkStart'. The default value is 500 milliseconds. |
Integer32r/w Constraints: range: 100-3000 |
.1.3.6.1.4.1.2011.5.25.1.3.4.3.1.7 |
|
hwVoAnalogIfEMTimerDialoutDelay
This object expresses max time sending called digits. This object can
only be used when hwVoAnalogIfEMConfigSignalMode is 'immediate'. The default value is 300 milliseconds. |
Integer32r/w Constraints: range: 50-5000 |
.1.3.6.1.4.1.2011.5.25.1.3.4.3.1.8 |
|
hwVoAnalogIfEMTimerRising
This object expresses the wait duration between receiveing seizure
signal and sending delay signal. This object can only be used when hwVoAnalogIfEMConfigSignalMode is 'delayDial'. The default value is 300 milliseconds. |
Integer32r/w Constraints: range: 20-2000 |
.1.3.6.1.4.1.2011.5.25.1.3.4.3.1.9 |
|
hwVoAnalogIfEMTimerHold
This object expresses the max time sending delay signal. This object
can only be used when hwVoAnalogIfEMConfigSignalMode is 'delayDial'. The default value is 400 milliseconds. |
Integer32r/w Constraints: range: 100-5000 |
.1.3.6.1.4.1.2011.5.25.1.3.4.3.1.10 |