hwVectoringGroupNotReqBandsDs
HUAWEI-VECTOR-MIB ·
.1.3.6.1.4.1.2011.6.171.2.1.3
Object
column
r/w
OctetString
This configuration parameter shall be an array of pairs of sub-carrier indices for downstream . Each pair represents the start and stop sub-carrier index of a frequency band in which FEXT cancellation is not required. Up to 8 frequency bands may be configured. for example :1300-1320,1400-1450. This parameter must be used together with hwVectoringGroupProtectionOfNotReqBandsDs. This parameter is configurable only when hwVectoringGroupProtectionOfNotReqBandsDs is enabled.
Context
- MIB
- HUAWEI-VECTOR-MIB
- OID
.1.3.6.1.4.1.2011.6.171.2.1.3- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- hwVectoringGroupEntry
Syntax
OctetString
Values & Constraints
Object Constraints
range: 0-79