hwMonitorLinkDownLinkUpTime

HUAWEI-PROTECTION-MIB · .1.3.6.1.4.1.2011.6.50.13.1.4

Object

Indicates the last time when the downstream port of the monitored groups is up.
The value format of this leaf is an 8-byte hexadecimal number. Among the eight 
bytes, the first and second bytes indicates the year, the third byte indicates 
the month, the fourth byte indicates the day, the fifth byte indicates the hour, 
the sixth byte indicates the minute, the seventh byte indicates 1/10 second and 
is fixedly filled with 0, and the eighth, ninth, and tenth bytes indicate the 
time zone. 
For example, if the time is 2010-2-8, 10:11:38 in GMT+ 8, the value is 0x07 0xDA 
0x02 0x08 0x0A 0x0B 0x26 0x00 0x2B 0x08 0x00.
Because the time range that can be identified by the device is from 1970-01-01 
00:00 to 2099-12-31 23:59, the time set for this leaf must within this time range.
The first 8-byte hexadecimal value is 0, it indicates invalid value.

Context

MIB
HUAWEI-PROTECTION-MIB
OID
.1.3.6.1.4.1.2011.6.50.13.1.4
Type
column
Access
readonly
Status
current
Parent
hwMonitorLinkDownLinkEntry

Walk the column to discover its indexed instances, or supply every index to read one instance.

Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'HUAWEI-PROTECTION-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'HUAWEI-PROTECTION-MIB::hwMonitorLinkDownLinkUpTime'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'HUAWEI-PROTECTION-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'HUAWEI-PROTECTION-MIB::hwMonitorLinkDownLinkUpTime.<hwMonitorLinkGroupId>.<hwMonitorLinkDownLinkId>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'HUAWEI-PROTECTION-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'HUAWEI-PROTECTION-MIB::hwMonitorLinkDownLinkUpTime'

Syntax

Source
SNMPv2-TCDateAndTime
Base type
OctetString
Display format
2d-1d-1d,1d:1d:1d.1d,1a1d:1d
Type Description
A date-time specification.
          
field  octets  contents                  range
-----  ------  --------                  -----
  1      1-2   year*                     0..65536
  2       3    month                     1..12
  3       4    day                       1..31
  4       5    hour                      0..23
  5       6    minutes                   0..59
  6       7    seconds                   0..60
               (use 60 for leap-second)
  7       8    deci-seconds              0..9
  8       9    direction from UTC        '+' / '-'
  9      10    hours from UTC*           0..13
 10      11    minutes from UTC          0..59
          
* Notes:
- the value of year is in network-byte order
- daylight saving time in New Zealand is +13
          
For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be
displayed as:
          
                 1992-5-26,13:30:15.0,-4:0
          
Note that if only local time is known, then timezone
information (fields 8-10) is not present.

Values & Constraints

Type Constraints
range: 8 range: 11