hwLdpInterfaceLocalLsrIdIfIndex
HUAWEI-MPLSLDP-MIB ·
.1.3.6.1.4.1.2011.5.25.143.1.54.1.19
Object
This object indicates the way to specify the interface that the local LDP LSR-ID based on interface is assigned to. Value: 0..2147483647 The default value of the object for the public interface is the interface that the global LDP LSR ID is assigned to. If the global LDP LSR ID is not assigned to any interface, then the value of the object is 0. If set 0, the value of the object will be the default value. The default value of the object for the private interface is the interface that the global LDP LSR ID of VPN Instance is assigned to. Based on mplsL3VpnIfConfRowStatus of mplsL3VpnIfConfTable, you can find which interface belongs to the VPN. The interface which the object specified must be bound with the same VPN instance with the interface which is configured.
Context
- MIB
- HUAWEI-MPLSLDP-MIB
- OID
.1.3.6.1.4.1.2011.5.25.143.1.54.1.19- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- hwLdpInterfaceEntry
- Table
- hwLdpInterfaceTable
- Siblings
- 10
Values & Constraints
Type Constraints
range: 0..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| hwLdpInterfaceIndex This object indicates the interface index.
You can get the correct interface index based on ifIndex of ifTable. | column | IF-MIBInterfaceIndex | .1.3.6.1.4.1.2011.5.25.143.1.54.1.1 |
| hwLdpStaticFrrProtectTimer obsolete This object indicates the value of static FRR protect timer.
Default: 10
Unit: seconds | column | Integer32 | .1.3.6.1.4.1.2011.5.25.143.1.54.1.11 |
| hwLdpKeepAliveTimer This object indicates the value of Keepalive timer.
Default: 45
Unit: seconds | column | Integer32 | .1.3.6.1.4.1.2011.5.25.143.1.54.1.12 |
| hwLdpIgpSyncTimer This object indicates the value of IGP-Sync timer. By default, the timer is set to 10 seconds.
Default: 10
Unit: seconds | column | Integer32 | .1.3.6.1.4.1.2011.5.25.143.1.54.1.13 |
| hwLdpHelloTimer This object indicates the value of Hello hold timer. By default, the value of the timer is 15 seconds.
Default: 15
Unit: seconds | column | Integer32 | .1.3.6.1.4.1.2011.5.25.143.1.54.1.14 |
| hwLdpTransportAddressIfIndex This object indicates the way to specify the interface that the Transport Address is assigned to.
Value: 0..2147483647
The default value of the object for the public interface is… | column | IF-MIBInterfaceIndexOrZero | .1.3.6.1.4.1.2011.5.25.143.1.54.1.15 |
| hwLdpKeepAliveSendTimer This object indicates the value of LDP Keepalive send timer.
Default: 0
Unit: seconds | column | Integer32 | .1.3.6.1.4.1.2011.5.25.143.1.54.1.16 |
| hwLdpHelloSendTimer This object indicates the value of LDP Hello send timer.
Default: 0
Unit: seconds | column | Integer32 | .1.3.6.1.4.1.2011.5.25.143.1.54.1.17 |
| hwLdpInterfaceLabelAdvertisementMode This object indicates the label distribution mode.
Options:
1. dod(1) -indicates that the label distribution mode is dod.
2. du(2) -indicates that the label distribution mode is … | column | Enumeration | .1.3.6.1.4.1.2011.5.25.143.1.54.1.18 |
| hwLdpInterfaceRowStatus This object indicates whether one entry of hwLdpInterfaceTable is created or destroyed.
The value of this object can be CreatAndGo or Destroy.
When the value of the object is se… | column | SNMPv2-TCRowStatus | .1.3.6.1.4.1.2011.5.25.143.1.54.1.51 |