hwIsisProcOnStartFromPeerInterval
HUAWEI-ISIS-CONF-MIB ·
.1.3.6.1.4.1.2011.5.25.24.2.1.3.1.23
Object
column
r/w
seconds Integer32
The value of this object identifies the maximum interval for waiting to clear the overload bit after the system is started and the neighbor relationship is established. The value ranges of set is from 5 to 86400, in seconds. The default value is 1200s. 0 means no configuration.
Context
- MIB
- HUAWEI-ISIS-CONF-MIB
- OID
.1.3.6.1.4.1.2011.5.25.24.2.1.3.1.23- Type
- column
- Access
- readwrite
- Status
- current
- Units
- seconds
- Parent
- hwIsisProcMTExtEntry
Syntax
seconds Integer32
Values & Constraints
Object Constraints
range: 0-0
range: 5-86400