hwIsisCircLdpHldMaxCost
HUAWEI-ISIS-CONF-MIB ·
.1.3.6.1.4.1.2011.5.25.24.2.1.21.1.20
Object
column
r/w
Integer32
The value of this object identifies the timeout period of the Hold-Max-Cost time for synchronization of IS-IS and LDP. The value ranges from 0 to 65536, in seconds. By default, the value is 10s. The value of 65536 means infinite. 0 means to stop Hold-Max-Cost timer. -1 means no configuration.
Context
- MIB
- HUAWEI-ISIS-CONF-MIB
- OID
.1.3.6.1.4.1.2011.5.25.24.2.1.21.1.20- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- hwIsisIntfBaseEntry
Syntax
Integer32
Values & Constraints
Object Constraints
range: -1-65536